SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Abdalla Munir A) "

Sökning: WFRF:(Abdalla Munir A)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • 2021
  • swepub:Mat__t
  •  
2.
  • Klionsky, Daniel J., et al. (författare)
  • Guidelines for the use and interpretation of assays for monitoring autophagy
  • 2012
  • Ingår i: Autophagy. - : Informa UK Limited. - 1554-8635 .- 1554-8627. ; 8:4, s. 445-544
  • Forskningsöversikt (refereegranskat)abstract
    • In 2008 we published the first set of guidelines for standardizing research in autophagy. Since then, research on this topic has continued to accelerate, and many new scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Accordingly, it is important to update these guidelines for monitoring autophagy in different organisms. Various reviews have described the range of assays that have been used for this purpose. Nevertheless, there continues to be confusion regarding acceptable methods to measure autophagy, especially in multicellular eukaryotes. A key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers or volume of autophagic elements (e.g., autophagosomes or autolysosomes) at any stage of the autophagic process vs. those that measure flux through the autophagy pathway (i.e., the complete process); thus, a block in macroautophagy that results in autophagosome accumulation needs to be differentiated from stimuli that result in increased autophagic activity, defined as increased autophagy induction coupled with increased delivery to, and degradation within, lysosomes (in most higher eukaryotes and some protists such as Dictyostelium) or the vacuole (in plants and fungi). In other words, it is especially important that investigators new to the field understand that the appearance of more autophagosomes does not necessarily equate with more autophagy. In fact, in many cases, autophagosomes accumulate because of a block in trafficking to lysosomes without a concomitant change in autophagosome biogenesis, whereas an increase in autolysosomes may reflect a reduction in degradative activity. Here, we present a set of guidelines for the selection and interpretation of methods for use by investigators who aim to examine macroautophagy and related processes, as well as for reviewers who need to provide realistic and reasonable critiques of papers that are focused on these processes. These guidelines are not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to monitor autophagy. In these guidelines, we consider these various methods of assessing autophagy and what information can, or cannot, be obtained from them. Finally, by discussing the merits and limits of particular autophagy assays, we hope to encourage technical innovation in the field.
  •  
3.
  • Abdalla, Munir A, et al. (författare)
  • A CMOS APS for dental X-ray imaging using scintillating sensors
  • 2001
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 460:1, s. 197-203
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper we present an integrating CMOS Active Pixel Sensor (APS) circuit to be used with scintillator type X-ray sensors for intra oral dental X-ray imaging systems. Different pixel architectures were constructed to explore their performance characteristics and to study the feasibility of the development of such systems using the CMOS technology. A prototype 64 x 80 pixel array has been implemented in a CMOS 0.8 mum double poly n-well process with a pixel pitch of 50 mum. A spectral sensitivity measurement for the different pixels topologies, as well as measured X-ray direct absorption in the different APSs are presented. A measurement of the output signal showed a good linearity over a wide dynamic range. This chip showed that the very low sensitivity of the CMOS APSs to direct X-ray exposure adds a great advantage to the various CMOS advantages over CCD-based imaging systems,
  •  
4.
  • Abdalla, Munir A, et al. (författare)
  • A new biasing method for CMOS preamplifier-shapers
  • 2000
  • Ingår i: ICECS 2000: 7TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS & SYSTEMS, VOLS I AND II. ; , s. 15-18
  • Konferensbidrag (refereegranskat)
  •  
5.
  • Abdalla, Munir A, et al. (författare)
  • An integrating CMOS APS for X-ray imaging with an in-pixel preamplifier
  • 2001
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 466:1, s. 232-236
  • Tidskriftsartikel (refereegranskat)abstract
    • We present in this paper an integrating CMOS Active Pixel Sensor (APS) circuit coated with scintillator type sensors for intra-oral dental X-ray imaging systems. The photosensing element in the pixel is formed by the p-diffusion on the n-well diode. The advantage of this photosensor is its very low direct absorption of X-rays compared to the other available photosensing elements in the CMOS pixel. The pixel features an integrating capacitor in the feedback loop of a preamplifier of a finite gain in order to increase the optical sensitivity. To verify the effectiveness of this in-pixel preamplification, a prototype 32 x 80 element CMOS active pixel array was implemented in a 0.8 mum CMOS double poly, n-well process with a pixel pitch of 50 mum. Measured results confirmed the improved optical sensitivity performance of the APS. Various measurements on device performance are presented.
  •  
6.
  •  
7.
  • Marchal, J, et al. (författare)
  • Active pixel detector for ion beam profiling
  • 2002
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 487:1-2, s. 224-231
  • Tidskriftsartikel (refereegranskat)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy