SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ahl M.) "

Sökning: WFRF:(Ahl M.)

  • Resultat 1-10 av 40
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Saliba-Gustafsson, P., et al. (författare)
  • Subclinical atherosclerosis and its progression are modulated by PLIN2 through a feed-forward loop between LXR and autophagy
  • 2019
  • Ingår i: Journal of Internal Medicine. - : Wiley. - 0954-6820 .- 1365-2796. ; 286:6, s. 660-675
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Hyperlipidaemia is a major risk factor for cardiovascular disease, and atherosclerosis is the underlying cause of both myocardial infarction and stroke. We have previously shown that the Pro251 variant of perilipin-2 reduces plasma triglycerides and may therefore be beneficial to reduce atherosclerosis development. Objective We sought to delineate putative beneficial effects of the Pro251 variant of perlipin-2 on subclinical atherosclerosis and the mechanism by which it acts. Methods A pan-European cohort of high-risk individuals where carotid intima-media thickness has been assessed was adopted. Human primary monocyte-derived macrophages were prepared from whole blood from individuals recruited by perilipin-2 genotype or from buffy coats from the Karolinska University hospital blood central. Results The Pro251 variant of perilipin-2 is associated with decreased intima-media thickness at baseline and over 30 months of follow-up. Using human primary monocyte-derived macrophages from carriers of the beneficial Pro251 variant, we show that this variant increases autophagy activity, cholesterol efflux and a controlled inflammatory response. Through extensive mechanistic studies, we demonstrate that increase in autophagy activity is accompanied with an increase in liver-X-receptor (LXR) activity and that LXR and autophagy reciprocally activate each other in a feed-forward loop, regulated by CYP27A1 and 27OH-cholesterol. Conclusions For the first time, we show that perilipin-2 affects susceptibility to human atherosclerosis through activation of autophagy and stimulation of cholesterol efflux. We demonstrate that perilipin-2 modulates levels of the LXR ligand 27OH-cholesterol and initiates a feed-forward loop where LXR and autophagy reciprocally activate each other; the mechanism by which perilipin-2 exerts its beneficial effects on subclinical atherosclerosis.
  •  
2.
  • Bass, Gary Alan, 1979-, et al. (författare)
  • Techniques for mesoappendix transection and appendix resection: insights from the ESTES SnapAppy study
  • 2023
  • Ingår i: European Journal of Trauma and Emergency Surgery. - : Springer Science and Business Media LLC. - 1863-9933 .- 1615-3146 .- 1863-9941. ; 49, s. 17-32
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Surgically managed appendicitis exhibits great heterogeneity in techniques for mesoappendix transection and appendix amputation from its base. It is unclear whether a particular surgical technique provides outcome benefit or reduces complications. Material and methods: We undertook a pre-specified subgroup analysis of all patients who underwent laparoscopic appendectomy at index admission during SnapAppy (ClinicalTrials.gov Registration: NCT04365491). We collected routine, anonymized observational data regarding surgical technique, patient demographics and indices of disease severity, without change to clinical care pathway or usual surgeon preference. Outcome measures of interest were the incidence of complications, unplanned reoperation, readmission, admission to the ICU, death, hospital length of stay, and procedure duration. We used Poisson regression models with robust standard errors to calculate incident rate ratios (IRRs) and 95% confidence intervals (CIs). Results: Three-thousand seven hundred sixty-eight consecutive adult patients, included from 71 centers in 14 countries, were followed up from date of admission for 90days. The mesoappendix was divided hemostatically using electrocautery in 1564(69.4%) and an energy device in 688(30.5%). The appendix was amputated by division of its base between looped ligatures in 1379(37.0%), with a stapler in 1421(38.1%) and between clips in 929(24.9%). The technique for securely dividing the appendix at its base in acutely inflamed (AAST Grade 1) appendicitis was equally divided between division between looped ligatures, clips and stapled transection. However, the technique used differed in complicated appendicitis (AAST Grade 2 +) compared with uncomplicated (Grade 1), with a shift toward transection of the appendix base by stapler (58% vs. 38%; p < 0.001). While no statistical difference in outcomes could be detected between different techniques for division of appendix base, decreased risk of any [adjusted IRR (95% CI): 0.58 (0.41–0.82), p = 0.002] and severe [adjusted IRR (95% CI): 0.33 (0.11–0.96), p = 0.045] complications could be detected when using energy devices. Conclusions: Safe mesoappendix transection and appendix resection are accomplished using heterogeneous techniques. Technique selection for both mesoappendix transection and appendix resection correlates with AAST grade. Higher grade led to more ultrasonic tissue transection and stapled appendix resection. Higher AAST appendicitis grade also correlated with infection-related complication occurrence. Despite the overall well-tolerated heterogeneity of approaches to acute appendicitis, increasing disease acuity or complexity appears to encourage homogeneity of intraoperative surgical technique toward advanced adjuncts.
  •  
3.
  • Forssten, Maximilian Peter, 1996-, et al. (författare)
  • Surgical management of acute appendicitis during the European COVID-19 second wave: safe and effective
  • 2023
  • Ingår i: European Journal of Trauma and Emergency Surgery. - : Springer Science and Business Media LLC. - 1863-9933 .- 1615-3146 .- 1863-9941. ; 49, s. 57-67
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: The COVID-19 (SARS-CoV-2) pandemic drove acute care surgeons to pivot from long established practice patterns. Early safety concerns regarding increased postoperative complication risk in those with active COVID infection promoted antibiotic-driven non-operative therapy for select conditions ahead of an evidence-base. Our study assesses whether active or recent SARS-CoV-2 positivity increases hospital length of stay (LOS) or postoperative complications following appendectomy. Methods: Data were derived from the prospective multi-institutional observational SnapAppy cohort study. This preplanned data analysis assessed consecutive patients aged ≥ 15years who underwent appendectomy for appendicitis (November 2020–May 2021). Patients were categorized based on SARS-CoV-2 seropositivity: no infection, active infection, and prior infection. Appendectomy method, LOS, and complications were abstracted. The association between SARS-CoV-2 seropositivity and complications was determined using Poisson regression, while the association with LOS was calculated using a quantile regression model. Results: Appendectomy for acute appendicitis was performed in 4047 patients during the second and third European COVID waves. The majority were SARS-CoV-2 uninfected (3861, 95.4%), while 70 (1.7%) were acutely SARS-CoV-2 positive, and 116 (2.8%) reported prior SARS-CoV-2 infection. After confounder adjustment, there was no statistically significant association between SARS-CoV-2 seropositivity and LOS, any complication, or severe complications. Conclusion: During sequential SARS-CoV-2 infection waves, neither active nor prior SARS-CoV-2 infection was associated with prolonged hospital LOS or postoperative complication. Despite early concerns regarding postoperative safety and outcome during active SARS-CoV-2 infection, no such association was noted for those with appendicitis who underwent operative management.
  •  
4.
  • Bagni, T., et al. (författare)
  • Modeling Results of the Quench Behavior of a Nb-Ti Canted-Cosine-Theta Corrector Magnet for LHC
  • 2024
  • Ingår i: IEEE transactions on applied superconductivity (Print). - : IEEE. - 1051-8223 .- 1558-2515. ; 34:5
  • Tidskriftsartikel (refereegranskat)abstract
    • A newly designed superconducting magnet of the Canted-Cosine-Theta (CCT) type was developed as a result of a collaboration between Swedish universities (Uppsala and Linneaus) and Swedish industries. This magnet was designed to function as a replacement of the present LHC orbit corrector magnets, which are approaching their end of life due to the radiation load. As a result, the new CCT magnet was developed to be more radiation tolerant and to constitute a one-to-one replacement to the currently installed version, which is a 1 m long 70 mm double aperture dipole magnet. The final magnet, which is currently under construction, will be tested at FREIA laboratory at Uppsala University and generate a magnetic field of 3.3 T and an integrated field of 2.8 Tm at about 85 A. To examine the magnet quench behavior and to identify a suitable quench protection system, the 3D electro-magnetic and thermal behavior of the coil was modeled using the RAT-Raccoon software. Based on the simulation results, a Metrosil varistor was selected to protect the magnet during the test. In this article, we report the results of the numerical analysis. The magnet model is equipped with a spot heater to initialize the quench and the temperature and voltages are monitored during the avalanche effect. The simulated current decay and the hot-spot temperature are analyzed with a focus on the impact of quench-back on the magnet protection.
  •  
5.
  •  
6.
  • Bagni, Tommaso, et al. (författare)
  • Modeling Results of the Quench Behavior of a Nb-Ti Canted-Cosine-Theta Corrector Magnet for LHC
  • 2024
  • Ingår i: IEEE transactions on applied superconductivity (Print). - : Institute of Electrical and Electronics Engineers (IEEE). - 1051-8223 .- 1558-2515. ; 34:5, s. 1-5
  • Tidskriftsartikel (refereegranskat)abstract
    • A newly designed superconducting magnet of the Canted-Cosine-Theta (CCT) type was developed as a result of a collaboration between Swedish universities (Uppsala and Linneaus) and Swedish industries. This magnet was designed to function as a replacement of the present LHC orbit corrector magnets, which are approaching their end of life due to the radiation load. As a result, the new CCT magnet was developed to be more radiation tolerant and to constitute a one-to-one replacement to the currently installed version, which is a 1 m long 70 mm double aperture dipole magnet. The final magnet, which is currently under construction, will be tested at FREIA laboratory at Uppsala University and generate a magnetic field of 3.3 T and an integrated field of 2.8 Tm at about 85 A. To examine the magnet quench behavior and to identify a suitable quench protection system, the 3D electro-magnetic and thermal behavior of the coil was modeled using the RAT-Raccoon software. Based on the simulation results, a Metrosil varistor was selected to protect the magnet during the test. In this article, we report the results of the numerical analysis. The magnet model is equipped with a spot heater to initialize the quench and the temperature and voltages are monitored during the avalanche effect. The simulated current decay and the hot-spot temperature are analyzed with a focus on the impact of quench-back on the magnet protection.
  •  
7.
  • Pepitone, K., et al. (författare)
  • Design and Fabrication of a Canted-Cosine-Theta Double Aperture Orbit Corrector Dipole for the LHC
  • 2023
  • Ingår i: IEEE transactions on applied superconductivity (Print). - : IEEE. - 1051-8223 .- 1558-2515 .- 2378-7074. ; 33:5
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype CCT dipole magnet developed by a collaboration between Swedish universities, Swedish industry and CERN will be tested at Uppsala University. This 1 m long double-aperture magnet can provide a field strength of 3.3 T at 85 A in a 70 mm aperture with an integrated field of 2.8 Tm. It is intended to replace the current LHC orbit corrector magnets which are reaching the end of their expected life due to the radiation load. The new magnet is designed to handle the radiation dose of the upgrade to the high-luminosity LHC, which will deliver about ten times the current radiation dose. It must therefore be more resistant to radiation and meet strict requirements in terms of electrical insulation while matching the original field quality and self-protective capability, mechanical volume, and maximum excitation current. This paper will present the latest of the design and manufacturing work, including the results of simulations of the mechanical field and the mechanical stress. Details of the various tests performed before machining the parts are also presented.
  •  
8.
  •  
9.
  • Henry, C., et al. (författare)
  • Women’s entrepreneurship policy : A 13-nation cross-country comparison
  • 2017
  • Ingår i: Entrepreneurial ecosystems and growth of women's entrepreneurship. - : Edward Elgar Publishing. - 9781785364624 - 9781785364617 ; , s. 244-278
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • Public policy is a key element within the entrepreneurial ecosystem in that policy has the potential to shape venture creation behavior and entrepreneurial outcomes. In response to studies documenting a gender gap in entrepreneurial activity, government attention to women’s entrepreneurship has increased in the past two decades. Nevertheless, there are few cross-cultural studies to inform policy development. This 13-nation study draws on gender and institutional theory to report on the status of female-focused SME/entrepreneurship policies and to ask: How - and to what extent - do women’s entrepreneurship policies differ among countries? A common methodological approach is used to identify gaps in the policy-practice nexus, highlighting countries where policy is weak but practice is strong and vice versa. Recommendations for future research are advanced. 
  •  
10.
  • Pepitone, Kevin, Dr, 1988-, et al. (författare)
  • Design and Fabrication of a Canted-Cosine-Theta Double Aperture Orbit Corrector Dipole for the LHC
  • 2023
  • Ingår i: IEEE transactions on applied superconductivity (Print). - : IEEE. - 1051-8223 .- 1558-2515. ; 33:5
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype CCT dipole magnet developed by a collaboration between Swedish universities, Swedish industry and CERN will be tested at Uppsala University. This 1 m long double-aperture magnet can provide a field strength of 3.3 T at 85 A in a 70 mm aperture with an integrated field of 2.8 Tm. It is intended to replace the current LHC orbit corrector magnets which are reaching the end of their expected life due to the radiation load. The new magnet is designed to handle the radiation dose of the upgrade to the high-luminosity LHC, which will deliver about ten times the current radiation dose. It must therefore be more resistant to radiation and meet strict requirements in terms of electrical insulation while matching the original field quality and self-protective capability, mechanical volume, and maximum excitation current. This paper will present the latest of the design and manufacturing work, including the results of simulations of the mechanical field and the mechanical stress. Details of the various tests performed before machining the parts are also presented.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 40
Typ av publikation
tidskriftsartikel (35)
bokkapitel (3)
rapport (1)
konferensbidrag (1)
Typ av innehåll
refereegranskat (36)
övrigt vetenskapligt/konstnärligt (3)
populärvet., debatt m.m. (1)
Författare/redaktör
Ahl, M (13)
Ahl, T (9)
Johansson, M (5)
Olsson, A (5)
Kirby, G (5)
Lindström, J. (4)
visa fler...
Hedstrom, M (4)
Olvegård, Maja, 1981 ... (3)
Axelsson, R (3)
Ruber, Roger (3)
Boden, H (3)
Salemyr, M (3)
Holstensson, M (3)
Andersson, U.B (3)
Kovacikova, Janka (3)
Högdahl, K. (3)
Brismar, H (3)
Akerlund, B (3)
Hedlund, H (3)
Karlsson, G (3)
Nicolai, A (2)
Larsson, Sune (2)
Pettersson, M. (2)
Olofsson, Christina (2)
Eriksson, P (2)
Cao, Yang, Associate ... (2)
Talving, Peep (2)
Mohseni, Shahin, 197 ... (2)
Cooper, J. (2)
Forssten, Maximilian ... (2)
Bass, Gary Alan, 197 ... (2)
DALEN, N (2)
Hamsten, A (2)
de Faire, U (2)
Ruber, R. (2)
Veglia, F (2)
Rauramaa, R (2)
Baldassarre, D (2)
Tremoli, E (2)
Amato, M (2)
Giral, P (2)
Kurl, S (2)
Ravani, A (2)
Frigerio, B (2)
Sansaro, D (2)
Castelnuovo, S (2)
Stark, A (2)
Sjöström, H (2)
Haralanova, Valentin ... (2)
Back, Johan (2)
visa färre...
Lärosäte
Karolinska Institutet (21)
Uppsala universitet (11)
Göteborgs universitet (4)
Lunds universitet (4)
Linnéuniversitetet (3)
Örebro universitet (2)
visa fler...
Linköpings universitet (2)
Umeå universitet (1)
Kungliga Tekniska Högskolan (1)
Jönköping University (1)
visa färre...
Språk
Engelska (40)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (8)
Naturvetenskap (7)
Teknik (2)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy