SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ahnesjö Anders) "

Sökning: WFRF:(Ahnesjö Anders)

  • Resultat 1-10 av 124
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Qatarneh, Sharif, 1972- (författare)
  • Development of a Whole Body Atlas for Radiation Therapy Planning and Treatment Optimization
  • 2006
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The main objective of radiation therapy is to obtain the highest possible probability of tumor cure while minimizing adverse reactions in healthy tissues. A crucial step in the treatment process is to determine the location and extent of the primary tumor and its loco regional lymphatic spread in relation to adjacent radiosensitive anatomical structures and organs at risk. These volumes must also be accurately delineated with respect to external anatomic reference points, preferably on surrounding bony structures. At the same time, it is essential to have the best possible physical and radiobiological knowledge about the radiation responsiveness of the target tissues and organs at risk in order to achieve a more accurate optimization of the treatment outcome.A computerized whole body Atlas has therefore been developed to serve as a dynamic database, with systematically integrated knowledge, comprising all necessary physical and radiobiological information about common target volumes and normal tissues. The Atlas also contains a database of segmented organs and a lymph node topography, which was based on the Visible Human dataset, to form standard reference geometry of organ systems. The reference knowledgebase and the standard organ dataset can be utilized for Atlas-based image processing and analysis in radiation therapy planning and for biological optimization of the treatment outcome. Atlas-based segmentation procedures were utilized to transform the reference organ dataset of the Atlas into the geometry of individual patients. The anatomic organs and target volumes of the database can be converted by elastic transformation into those of the individual patient for final treatment planning. Furthermore, a database of reference treatment plans was started by implementing state-of-the-art biologically based radiation therapy planning techniques such as conformal, intensity modulated, and radiobiologically optimized treatment planning.The computerized Atlas can be viewed as a central framework that contains different forms of optimal treatment plans linked to all the essential information needed in treatment planning, which can be adapted to a given patient, in order to speed up treatment plan convergence. The Atlas also offers a platform to synthesize the results of imaging studies through its advanced geometric transformation and segmentation procedures. The whole body Atlas is anticipated to become a physical and biological knowledgebase that can facilitate, speed up and increase the accuracy in radiation therapy planning and treatment optimization.
  •  
2.
  • Ahnesjö, Anders, et al. (författare)
  • Application of the convolution method for calculation of output factors for therapy photon beams
  • 1992
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 19:2, s. 295-301
  • Tidskriftsartikel (refereegranskat)abstract
    • The output factor for a therapy photon beam is defined as the dose per monitor unit relative to the dose per monitor unit in a reference field. Convolution models for photon dose calculations yield the dose in units normalized to the incident energy fluence with phantom scatter intrinsically modeled. Output factors calculated with the convolution method as the dose per unit energy fluence relative to the calculated dose per unit energy fluence in a reference field could deviate as much as 5% if corrections are not made for perturbations due to treatment head scatter. Significant perturbations are particles backscattered from the collimators to the monitor and photons forward scattered from the filter and collimators in the treatment head. The forward scatter adds an "unmonitored" contribution to the total energy fluence of the beam. A model is developed that describes the field size dependence of these perturbations for conversion of output factors, calculated with the convolution method, to machine output factors as an integrated part in treatment planning. The necessary machine characteristics are derived from measurements of the output in air for a limited set of field sizes. The method has been tested using five different multileaf collimated irregular fields at 6 MV and for a large set of rectangular fields at 5, 6, and 18 MV and found to predict output factors with an accuracy better than 1%.
  •  
3.
  • Ahnesjö, Anders, et al. (författare)
  • Beam modeling and verification of a photon beam multisource model.
  • 2005
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 32:6, s. 1722-37
  • Tidskriftsartikel (refereegranskat)abstract
    • Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated the development of multisource beam models. We describe and evaluate clinical photon beam modeling based on multisource models, including lateral beam quality variations. The evaluation is based on user data for a pencil kernel algorithm and a point kernel algorithm (collapsed cone) used in the clinical treatment planning systems Helax-TMS and Nucletron-Oncentra. The pencil kernel implementations treat the beam spectrum as lateral invariant while the collapsed cone involves off axis softening of the spectrum. Both algorithms include modeling of head scatter components. The parameters of the beam model are derived from measured beam data in a semiautomatic process called RDH (radiation data handling) that, in sequential steps, minimizes the deviations in calculated dose versus the measured data. The RDH procedure is reviewed and the results of processing data from a large number of treatment units are analyzed for the two dose calculation algorithms. The results for both algorithms are similar, with slightly better results for the collapsed cone implementations. For open beams, 87% of the machines have maximum errors less than 2.5%. For wedged beams the errors were found to increase with increasing wedge angle. Internal, motorized wedges did yield slightly larger errors than external wedges. These results reflect the increased complexity, both experimentally and computationally, when wedges are used compared to open beams.
  •  
4.
  • Ahnesjö, Anders, et al. (författare)
  • The IMRT information process-mastering the degrees of freedom in external beam therapy
  • 2006
  • Ingår i: Physics in Medicine and Biology. - 0031-9155 .- 1361-6560. ; 51:13, s. R381-402
  • Tidskriftsartikel (refereegranskat)abstract
    • The techniques and procedures for intensity-modulated radiation therapy (IMRT) are reviewed in the context of the information process central to treatment planning and delivery of IMRT. A presentation is given of the evolution of the information based radiotherapy workflow and dose delivery techniques, as well as the volume and planning concepts for relating the dose information to image based patient representations. The formulation of the dose shaping process as an optimization problem is described. The different steps in the calculation flow for determination of machine parameters for dose delivery are described starting from the formulation of optimization objectives over dose calculation to optimization procedures. Finally, the main elements of the quality assurance procedure necessary for implementing IMRT clinically are reviewed.
  •  
5.
  • Grönlund, Eric, et al. (författare)
  • Dose painting by numbers based on retrospectively determined recurrence probabilities
  • 2017
  • Ingår i: Radiotherapy and Oncology. - : ELSEVIER IRELAND LTD. - 0167-8140 .- 1879-0887. ; 122:2, s. 236-241
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: The aim of this study is to derive "dose painting by numbers" prescriptions from retrospectively observed recurrence volumes in a patient group treated with conventional radiotherapy for head and neck squamous cell carcinoma. Materials and methods: The spatial relation between retrospectively observed recurrence volumes and pre-treatment standardized uptake values (SUV) from fluorodeoxyglucose positron emission tomography (FDG-PET) imaging was determined. Based on this information we derived SUV driven dose-response functions and used these to optimize ideal dose redistributions under the constraint of equal average dose to the tumor volumes as for a conventional treatment. The response functions were also implemented into a treatment planning system for realistic dose optimization. Results: The calculated tumor control probabilities (TCP) increased between 0.1-14.6% by the ideal dose redistributions for all included patients, where patients with larger and more heterogeneous tumors got greater increases than smaller and more homogeneous tumors. Conclusions: Dose painting prescriptions can be derived from retrospectively observed recurrence volumes spatial relation to pre-treatment FDG-PET image data. The ideal dose redistributions could significantly increase the TCP for patients with large tumor volumes and large spread in SUV from FDG-PET. The results yield a basis for prospective studies to determine the clinical value for dose painting of head and neck squamous cell carcinomas.
  •  
6.
  • Sjöberg, Carl, et al. (författare)
  • Clinical evaluation of multi-atlas based segmentation of lymph node regions in head and neck and prostate cancer patients
  • 2013
  • Ingår i: Radiation Oncology. - : BioMed Central. - 1748-717X .- 1748-717X. ; 8, s. Article number: 229-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Semi-automated segmentation using deformable registration of selected atlas cases consisting of expert segmented patient images has been proposed to facilitate the delineation of lymph node regions for three-dimensional conformal and intensity-modulated radiotherapy planning of head and neck and prostate tumours. Our aim is to investigate if fusion of multiple atlases will lead to clinical workload reductions and more accurate segmentation proposals compared to the use of a single atlas segmentation, due to a more complete representation of the anatomical variations. Methods: Atlases for lymph node regions were constructed using 11 head and neck patients and 15 prostate patients based on published recommendations for segmentations. A commercial registration software (Velocity AI) was used to create individual segmentations through deformable registration. Ten head and neck patients, and ten prostate patients, all different from the atlas patients, were randomly chosen for the study from retrospective data. Each patient was first delineated three times, (a) manually by a radiation oncologist, (b) automatically using a single atlas segmentation proposal from a chosen atlas and (c) automatically by fusing the atlas proposals from all cases in the database using the probabilistic weighting fusion algorithm. In a subsequent step a radiation oncologist corrected the segmentation proposals achieved from step (b) and (c) without using the result from method (a) as reference. The time spent for editing the segmentations was recorded separately for each method and for each individual structure. Finally, the Dice Similarity Coefficient and the volume of the structures were used to evaluate the similarity between the structures delineated with the different methods. Results: For the single atlas method, the time reduction compared to manual segmentation was 29% and 23% for head and neck and pelvis lymph nodes, respectively, while editing the fused atlas proposal resulted in time reductions of 49% and 34%. The average volume of the fused atlas proposals was only 74% of the manual segmentation for the head and neck cases and 82% for the prostate cases due to a blurring effect from the fusion process. After editing of the proposals the resulting volume differences were no longer statistically significant, although a slight influence by the proposals could be noticed since the average edited volume was still slightly smaller than the manual segmentation, 9% and 5%, respectively. Conclusions: Segmentation based on fusion of multiple atlases reduces the time needed for delineation of lymph node regions compared to the use of a single atlas segmentation. Even though the time saving is large, the quality of the segmentation is maintained compared to manual segmentation.
  •  
7.
  • Abbasinejad Enger, Shirin, 1975- (författare)
  • Dosimetry Studies of Different Radiotherapy Applications using Monte Carlo Radiation Transport Calculations
  • 2008
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Developing radiation delivery systems for optimisation of absorbed dose to the target without normal tissue toxicity requires advanced calculations for transport of radiation. In this thesis absorbed dose and fluence in different radiotherapy applications were calculated by using Monte Carlo (MC) simulations.In paper I-III external neutron activation of gadolinium (Gd) for intravascular brachytherapy (GdNCB) and tumour therapy (GdNCT) was investigated. MC codes MCNP and GEANT4 were compared. MCNP was chosen for neutron capture reaction calculations. Gd neutron capture reaction includes both very short range (Auger electrons) and long range (IC electrons and gamma) products. In GdNCB the high-energetic gamma gives an almost flat absorbed dose delivery pattern, up to 4 mm around the stent. Dose distribution at the edges and inside the stent may prevent stent edge and in-stent restenosis. For GdNCT the absorbed dose from prompt gamma will dominate over the dose from IC and Auger electrons in an in vivo situation. The absorbed dose from IC electrons will enhance the total absorbed dose in the tumours and contribute to the cell killing.In paper IV a model for calculation of inter-cluster cross-fire radiation dose from β-emitting radionuclides in a breast cancer model was developed. GEANT4 was used for obtaining absorbed dose. The dose internally in cells binding the isotope (self-dose) increased with decreasing β-energy except for the radionuclides with substantial amounts of conversion electrons and Auger electrons. An effective therapy approach may be a combination of radionuclides where the high self-dose from nuclides with low β-energy should be combined with the inter-cell cluster cross-fire dose from high energy β-particles.In paper V MC simulations using correlated sampling together with importance sampling were used to calculate spectra perturbations in detector volumes caused by the detector silicon chip and its encapsulation. Penelope and EGSnrc were used and yielded similar results. The low energy part of the electron spectrum increased but to a less extent if the silicon detector was encapsulated in low z-materials.
  •  
8.
  • Ahnesjö, Anders, 1953-, et al. (författare)
  • Collapsed cone dose calculations for heterogeneous tissues in brachytherapy using primary and scatter separation source data
  • 2017
  • Ingår i: Computer Methods and Programs in Biomedicine. - : ELSEVIER IRELAND LTD. - 0169-2607 .- 1872-7565. ; 139, s. 17-29
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Objective: Brachytherapy is a form of radiation therapy using sealed radiation sources inserted within or in the vicinity of the tumor of, e.g., gynecological, prostate or head and neck cancers. Accurate dose calculation is a crucial part of the treatment planning. Several reviews have called for clinical software with model-based algorithms that better take into account the effects of patient individual distribution of tissues, source-channel and shielding attenuation than the commonly employed TG-43 formalism which simply map homogeneous water dose distributions onto the patient. In this paper we give a comprehensive and thorough derivation of such an algorithm based on collapsed cone point-kernel superposition, and describe details of its implementation into a commercial treatment planning system for clinical use. Methods: A brachytherapy version of the collapsed-cone algorithm using analytical raytraces of the primary photon radiation followed by successive scattering dose calculation for once and multiply scattered photons is described in detail, including derivation of the corresponding set of recursive equations for energy transport along cone axes/transport lines and the coupling to clinical source modeling. Specific implementation issues for setting up of the calculation grid, handling of intravoxel gradients and voxels partly containing non patient applicator material are given. Results: Sample runs for two clinical cases are shown, one being a gynecological application with a tungsten-shielded applicator and one a breast implant. These two cases demonstrate the impact of improved dose calculation versus TG-43 formalism. Conclusions: Use of model-based dose calculation algorithms for brachytherapy taking the three-dimensional treatment geometry into account increases the dosimetric accuracy in planning and follow up of treatments. The comprehensive description and derivations provided gives a rigid background for further clinical, educational and research applications.
  •  
9.
  • Ahnesjö, Anders, et al. (författare)
  • Detector response modeling
  • 2009
  • Patent (populärvet., debatt m.m.)abstract
    • A detector response correction arrangement and method is proposed for online determination of correction factors for arbitrary positions from arbitrary incident fluence distributions. As modern radiotherapy utilizes more of the available degrees of freedom of radiation machines, dosimetry has to be able to present reliable measurements for all these degrees of freedom. To determine correction factors online during measurement, Monte Carlo technique is used to precalculate fluence pencil kernels from a monodirectional beam to fully describe the particle fluence in an irradiated medium. Assuming that the particle fluence is not significantly altered by the introduction of a small detector volume, the fluence pencil kernels (212) can be integrated (214), and correction factors (216) determined, e.g. by Cavity Theory, in different positions for the detector material.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 124
Typ av publikation
tidskriftsartikel (93)
doktorsavhandling (14)
bokkapitel (6)
annan publikation (5)
forskningsöversikt (3)
rapport (1)
visa fler...
bok (1)
patent (1)
visa färre...
Typ av innehåll
refereegranskat (92)
övrigt vetenskapligt/konstnärligt (29)
populärvet., debatt m.m. (3)
Författare/redaktör
Ahnesjö, Anders (65)
Ahnesjö, Anders, 195 ... (32)
Nyholm, Tufve (18)
Tilly, Nina (16)
Karlsson, Mikael (15)
Traneus, Erik (15)
visa fler...
Olofsson, Jörgen (14)
Ahnesjö, Jonas (12)
Forsman, Anders (12)
Almhagen, Erik (9)
Johansson, Silvia (9)
Tilly, David, 1974- (8)
Berglund, Anders (7)
Ahnesjö, Ingrid (7)
Grusell, Erik (7)
Weber, Lars (6)
Eklund, Karin, 1978- (6)
Villegas, Fernanda, ... (6)
Nilsson, Per (5)
Isacsson, Ulf (5)
Knöös, Tommy (4)
Ahnesjö, Anders, Pro ... (4)
Montelius, Anders (4)
Caesar, Sofia (4)
Civantos, E (4)
Dasu, Alexandru, 197 ... (3)
Andersson, Karin M., ... (3)
Vallhagen Dahlgren, ... (3)
Fernández-Varea, Jos ... (3)
Das, Indra J (3)
Glimelius, Bengt (2)
Alm Carlsson, Gudrun (2)
Nilsson, Kristina (2)
Kvarnemo, Charlotta, ... (2)
Saxner, Mikael (2)
Vincent, Amanda (2)
Nilsson, Kristina, 1 ... (2)
Seuntjens, J (2)
Thunberg, Per, 1968- (2)
Andersson, Jonas, 19 ... (2)
Reizenstein, Johan (2)
Rosenqvist, Gunilla (2)
Enger, S (2)
Söderberg, Jonas (2)
Zhu, Timothy C (2)
Backstrom, G (2)
Kjaer-Kristoffersen, ... (2)
Bäckström, Gloria, 1 ... (2)
Bäckström, Gloria (2)
Cheng, Chee-Wai (2)
visa färre...
Lärosäte
Uppsala universitet (92)
Umeå universitet (22)
Linnéuniversitetet (13)
Lunds universitet (8)
Stockholms universitet (4)
Linköpings universitet (4)
visa fler...
Karolinska Institutet (4)
Örebro universitet (3)
Göteborgs universitet (2)
visa färre...
Språk
Engelska (121)
Svenska (2)
Odefinierat språk (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (53)
Naturvetenskap (22)
Teknik (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy