SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Al Rashidi Faleh) "

Sökning: WFRF:(Al Rashidi Faleh)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Al-Rashidi, Faleh, et al. (författare)
  • A new de-airing technique that reduces systemic microemboli during open surgery: a prospective controlled study.
  • 2009
  • Ingår i: The Journal of thoracic and cardiovascular surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 138:1, s. 157-162
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: We have evaluated a new technique of cardiac de-airing that is aimed at a) minimizing air from entering into the pulmonary veins by opening both pleurae and allowing lungs to collapse and b) flushing out residual air from the lungs by staged cardiac filling and lung ventilation. These air emboli are usually trapped in the pulmonary veins and may lead to ventricular dysfunction, life-threatening arrhythmias, and transient or permanent neurologic deficits. METHODS: Twenty patients undergoing elective true left open surgery were prospectively and alternately enrolled in the study to the conventional de-airing technique (pleural cavities unopened, dead space ventilation during cardiopulmonary bypass [control group]) and the new de-airing technique (pleural cavities open, ventilator disconnected during cardiopulmonary bypass, staged perfusion, and ventilation of lungs during de-airing [study group]). Transesophageal echocardiography and transcranial Doppler continually monitored the air emboli during the de-airing period and for 10 minutes after termination of the cardiopulmonary bypass. RESULTS: The amount of air embolism as observed on echocardiography and the number of microembolic signals as recorded by transcranial Doppler were significantly less in the study group during the de-airing time (P < .001) and the first 10 minutes after termination of cardiopulmonary bypass (P < .001). Further, the de-airing time was significantly shorter in the study group (10 vs 17 minutes, P < .001). CONCLUSION: The de-airing technique evaluated in this study is simple, reproducible, controlled, safe, and effective. Moreover, it is cost-effective because the de-airing time is short and no extra expenses are involved.
  •  
2.
  • Al Rashidi, Faleh, et al. (författare)
  • Comparison of the effectiveness and safety of a new de-airing technique with a standardized carbon dioxide insufflation technique in open left heart surgery: A randomized clinical trial.
  • 2011
  • Ingår i: The Journal of thoracic and cardiovascular surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; okt, s. 1128-1133
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: We have compared the effectiveness, time required for de-airing, and safety of a newly developed de-airing technique for open left heart surgery (Lund technique) with a standardized carbon dioxide insufflation technique. METHODS: Twenty patients undergoing elective open aortic valve surgery were randomized prospectively to the Lund technique (Lund group, n = 10) or the carbon dioxide insufflation technique (carbon dioxide group, n = 10). Both groups were monitored intraoperatively during de-airing and for 10 minutes after weaning from cardiopulmonary bypass by transesophageal echocardiography and online transcranial Doppler for the severity and the number of gas emboli, respectively. The systemic arterial partial pressure of carbon dioxide and pH were also monitored in both groups before, during, and after cardiopulmonary bypass. RESULTS: The severity of gas emboli observed on transesophageal echocardiography and the number of microembolic signals recorded by transcranial Doppler were significantly lower in the Lund group during the de-airing procedure (P = .00634) and in the first 10 minutes after weaning from cardiopulmonary bypass (P = .000377). Furthermore, the de-airing time was significantly shorter in the Lund group (9 vs 15 minutes, P = .001). The arterial pH during the cooling phase of cardiopulmonary bypass was significantly lower in the carbon dioxide group (P = .00351), corresponding to significantly higher arterial partial pressure of carbon dioxide (P = .005196) despite significantly higher gas flows (P = .0398) in the oxygenator throughout the entire period of cardiopulmonary bypass. CONCLUSIONS: The Lund de-airing technique is safer, simpler, and more effective compared with the carbon dioxide insufflation technique. The technique is also more cost-effective because the de-airing time is shorter and no extra expenses are incurred.
  •  
3.
  • Al Rashidi, Faleh, et al. (författare)
  • The modified Ross operation using a Dacron prosthetic vascular jacket does prevent pulmonary autograft dilatation at 4.5-year follow-up.
  • 2010
  • Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940. ; 37, s. 928-933
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Following the Ross operation, pulmonary autografts tend to dilate over time. This study researches the fate of the pulmonary autograft - at 4.5 years following the modified Ross operation - with special reference to the impact of the modification on (a) pulmonary autograft dilatation, (b) the neo-aortic root geometry, (c) neo-aortic valve function and (d) the coronary artery reserve. Methods: A total of 26 patients who underwent the Ross operation were included in this study; of these, 13 consecutive patients underwent a modified Ross operation in which the free-standing autograft root was supported externally by a Dacron vascular prosthetic jacket (DVPJ). These patients were compared to a cohort of 13 matched patients who were operated on using the conventional Ross technique; all patients were followed up prospectively by echocardiography studies. The patients who underwent the modified Ross operation were also subjected to bicycle ergometry. Results: At the 47-month median follow-up, there was no significant increase in the size of the entire neo-aortic root in the patients who underwent the modified Ross operation; in addition, the geometry of the neo-aortic root was also preserved and the left ventricular function had improved significantly, whilst the aortic valve function and excursion remained satisfactory. All patients, with one exception, in the modified Ross operation group exhibited normal exercise capacity. By contrast, there were significant differences in diameters of the aortic root - between the two surgical techniques in favour of the modified Ross technique - following a median follow-up of 23 months in the patients subjected to the conventional Ross operation. Conclusions: Provision of external support to the entire pulmonary autograft with a DVPJ prevents its dilatation following free-standing pulmonary autograft Ross operation when evaluated at the 4.5-year follow-up. The function and the geometry of the neo-aortic root are not affected negatively by this modification and the patients demonstrated normal exercise capacity.
  •  
4.
  • Bjursten, Henrik, et al. (författare)
  • Risks Associated With the Transfusion of Various Blood Products in Aortic Valve Replacement.
  • 2013
  • Ingår i: Annals of Thoracic Surgery. - : Elsevier BV. - 1552-6259 .- 0003-4975. ; 96:2, s. 494-499
  • Tidskriftsartikel (refereegranskat)abstract
    • Patients undergoing cardiac operations often require transfusions of red blood cells, plasma, and platelets. From a statistical point of view, there is a significant collinearity between the components, but they differ in indications for use and composition. This study explores the relationship between the transfusion of different blood components and long-term mortality in patients undergoing aortic valve replacement alone or combined with revascularization.
  •  
5.
  •  
6.
  • Koul, Bansi, et al. (författare)
  • A modified Ross operation to prevent pulmonary autograft dilatation.
  • 2007
  • Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940. ; 31:1, s. 127-128
  • Tidskriftsartikel (refereegranskat)abstract
    • A modification in Ross operation is described in which the free-standing pulmonary autograft root is suspended in a Dacron prosthetic vascular jacket with a view to prevent dilatation of the neo-aortic root. In a group of 13 patients operated consecutively using this technique, there was no significant increase in the diameters of the neo-aortic root after a mean 16-month follow-up. Aortic valve function remained also satisfactory.
  •  
7.
  •  
8.
  •  
9.
  • Landenhed Smith, Maya, et al. (författare)
  • Systemic effects of carbon dioxide insufflation technique for de-airing in left-sided cardiac surgery.
  • 2014
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 147:1, s. 295-300
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Systemic effects of carbon dioxide (CO(2)) insufflation during left-sided cardiac surgery were evaluated in a prospective randomized study, with regard to acid-base status, gas exchange, cerebral hemodynamics, and red blood cell morphology. METHODS: Twenty patients undergoing elective left-sided cardiac surgery were randomized to de-airing procedure either by CO(2) insufflation technique (CO(2) group, n = 10) or by Lund technique without CO(2) insufflation (Lund group, n = 10). Groups underwent assessment of acid-base status by intermittent arterial blood gases and in-line blood gas monitoring. Capnography was used to determine volume of CO(2) produced. Cerebral hemodynamics was measured by transcranial Doppler sonography and near-infrared spectroscopy. Red cell morphology from cardiotomy suction and vent tubing was studied by scanning electron microscopy. RESULTS: Patients in the CO(2) group consequently developed significantly higher levels of hypercapnia with a concomitant increase in the volume of CO(2) produced despite significantly higher oxygenator gas flows compared with the Lund group. Effects on cerebral hemodynamics were observed in the CO(2) group with significantly higher blood flow velocities in the middle cerebral artery and higher regional cerebral saturation. Red blood cell damage was observed in the CO(2) group by scanning electron microscopy (97% in CO(2) group vs 18% in Lund group). CONCLUSIONS: Insufflation of CO(2) into the cardiothoracic wound cavity during left-sided cardiac surgery can induce hypercapnic acidosis and increased cerebral blood flow and local blood cell damage. These systemic effects should be monitored by in-line capnography and acid-base measurements for early and effective correction by increase in gas flows to the oxygenator.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy