SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Aldous Sally J.) "

Sökning: WFRF:(Aldous Sally J.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Eggers, Kai M., 1962-, et al. (författare)
  • Diagnostic and prognostic performance of the ratio between high-sensitivity cardiac troponin I and troponin T in patients with chest pain
  • 2022
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 17:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.Methods We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99(th) percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.Results The median hs-cTn I/T ratio was 3.45 (25(th), 75(th) percentiles 1.80-6.59) in type 1 MI patients (n = 408 (sic) 46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 (sic) 6.3%]) and 0.67 (0.39-1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 (sic) 95% confidence interval 0.86-0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 (sic) 95% confidence interval 0.74-0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.Conclusions The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
  •  
2.
  • Eggers, Kai M., 1962-, et al. (författare)
  • Diagnostic and prognostic performance of the ratio between high-sensitivity cardiac troponin I and troponin T in patients with chest pain.
  • 2022
  • Ingår i: PloS one. - : Public Library of Science (PLoS). - 1932-6203. ; 17:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99th percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.The median hs-cTn I/T ratio was 3.45 (25th, 75th percentiles 1.80-6.59) in type 1 MI patients (n = 408 ☯46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 ☯6.3%]) and 0.67 (0.39-1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 ☯95% confidence interval 0.86-0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 ☯95% confidence interval 0.74-0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
  •  
3.
  • Lipinski, Michael J., et al. (författare)
  • Comparison of conventional and high-sensitivity troponin in patients with chest pain : A collaborative meta-analysis
  • 2015
  • Ingår i: American Heart Journal. - : Elsevier BV. - 0002-8703 .- 1097-6744. ; 169:1, s. 6-16.e6
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Multiple studies have evaluated the diagnostic and prognostic performance of conventional troponin (cTn) and high-sensitivity troponin (hs-cTn). We performed a collaborative meta-analysis comparing cTn and hs-cTn for diagnosis of acute myocardial infarction (AMI) and assessment of prognosis in patients with chest pain. Methods MEDLINE/PubMed, Cochrane CENTRAL, and EMBASE were searched for studies assessing both cTn and hs-cTn in patients with chest pain. Study authors were contacted and many provided previously unpublished data. Results From 17 included studies, there were 8,644 patients. Compared with baseline cTn, baseline hs-cTn had significantly greater sensitivity (0.884 vs 0.749, P < .001) and negative predictive value (NPV; 0.964 vs 0.935, P < .001), whereas specificity (0.816 vs 0.938, P < .001) and positive predictive value (0.558 vs 0.759, P < .001) were significantly reduced. Based on summary receiver operating characteristic curves, test performance for the diagnosis of AMI was not significantly different between baseline cTn and hs-cTn (0.90 [95% CI 0.85-0.95] vs 0.92 [95% CI 0.90-0.94]). In a subanalysis of 6 studies that alternatively defined AMI based on hs-cTn, cTn had lower sensitivity (0.666, P < .001) and NPV (0.906, P < .001). Elevation of baseline hs-cTn, but negative baseline cTn, was associated with increased risk of death or nonfatal myocardial infarction during follow-up (P < .001) compared with both negative. Conclusion High-sensitivity troponin has significantly greater early sensitivity and NPV for the diagnosis of AMI at the cost of specificity and positive predictive value, which may enable early rule in/out of AMI in patients with chest pain. Baseline hs-cTn elevation in the setting of negative cTn is also associated with increased nonfatal myocardial infarction or death during follow-up.
  •  
4.
  • Pickering, John W., et al. (författare)
  • Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of Detection A Collaborative Meta-analysis
  • 2017
  • Ingår i: Annals of Internal Medicine. - 0003-4819 .- 1539-3704. ; 166:10, s. 715-724
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: High-sensitivity assays for cardiac troponin T (hs-cTnT) are sometimes used to rapidly rule out acute myocardial infarction (AMI). Purpose: To estimate the ability of a single hs-cTnT concentration below the limit of detection (<0.005 mu g/L) and a nonischemic electrocardiogram (ECG) to rule out AMI in adults presenting to the emergency department (ED) with chest pain. Data Sources: EMBASE and MEDLINE without language restrictions (1 January 2008 to 14 December 2016). Study Selection: Cohort studies involving adults presenting to the ED with possible acute coronary syndrome in whom an ECG and hs-cTnT measurements were obtained and AMI outcomes adjudicated during initial hospitalization. Data Extraction: Investigators of studies provided data on the number of low-risk patients (no new ischemia on ECG and hs-cTnT measurements <0.005 mu g/L) and the number who had AMI during hospitalization (primary outcome) or a major adverse cardiac event (MACE) or death within 30 days (secondary outcomes), by risk classification (low or not low risk). Two independent epidemiologists rated risk of bias of studies. Data Synthesis: Of 9241 patients in 11 cohort studies, 2825 (30.6%) were classified as low risk. Fourteen (0.5%) low-risk patients had AMI. Sensitivity of the risk classification for AMI ranged from 87.5% to 100% in individual studies. Pooled estimated sensitivity was 98.7% (95% CI, 96.6% to 99.5%). Sensitivity for 30-day MACEs ranged from 87.9% to 100%; pooled sensitivity was 98.0% (CI, 94.7% to 99.3%). No low-risk patients died. Limitation: Few studies, variation in timing and methods of reference standard troponin tests, and heterogeneity of risk and prevalence of AMI across studies. Conclusion: A single hs-cTnT concentration below the limit of detection in combination with a nonischemic ECG may successfully rule out AMI in patients presenting to EDs with possible emergency acute coronary syndrome.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy