SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Amann Philipp M) "

Sökning: WFRF:(Amann Philipp M)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Mathey, Carina M, et al. (författare)
  • Molecular Genetic Screening in Patients With ACE Inhibitor/Angiotensin Receptor Blocker-Induced Angioedema to Explore the Role of Hereditary Angioedema Genes
  • 2022
  • Ingår i: Frontiers in Genetics. - : Frontiers Media S.A.. - 1664-8021. ; 13
  • Tidskriftsartikel (refereegranskat)abstract
    • Angioedema is a relatively rare but potentially life-threatening adverse reaction to angiotensin-converting enzyme inhibitors (ACEi) and angiotensin receptor blockers (ARBs). As with hereditary forms of angioedema (HAE), this adverse reaction is mediated by bradykinin. Research suggests that ACEi/ARB-induced angioedema has a multifactorial etiology. In addition, recent case reports suggest that some ACEi/ARB-induced angioedema patients may carry pathogenic HAE variants. The aim of the present study was to investigate the possible association between ACEi/ARB-induced angioedema and HAE genes via systematic molecular genetic screening in a large cohort of ACEi/ARB-induced angioedema cases. Targeted re-sequencing of five HAE-associated genes (SERPING1, F12, PLG, ANGPT1, and KNG1) was performed in 212 ACEi/ARB-induced angioedema patients recruited in Germany/Austria, Sweden, and Denmark, and in 352 controls from a German cohort. Among patients, none of the identified variants represented a known pathogenic variant for HAE. Moreover, no significant association with ACEi/ARB-induced angioedema was found for any of the identified common [minor allele frequency (MAF) >5%] or rare (MAF < 5%) variants. However, several non-significant trends suggestive of possible protective effects were observed. The lowest p-value for an individual variant was found in PLG (rs4252129, p.R523W, p = 0.057, p.adjust > 0.999, Fisher's exact test). Variant p.R523W was found exclusively in controls and has previously been associated with decreased levels of plasminogen, a precursor of plasmin which is part of a pathway directly involved in bradykinin production. In addition, rare, potentially functional variants (MAF < 5%, Phred-scaled combined annotation dependent depletion score >10) showed a nominally significant enrichment in controls both: 1) across all five genes; and 2) in the F12 gene alone. However, these results did not withstand correction for multiple testing. In conclusion, our results suggest that HAE-associated mutations are, at best, a rare cause of ACEi/ARB-induced angioedema. Furthermore, we were unable to identify a significant association between ACEi/ARB-induced angioedema and other variants in the investigated genes. Further studies with larger sample sizes are warranted to draw more definite conclusions concerning variants with limited effect sizes, including protective variants.
  •  
2.
  • Chiang, Cho-Han, et al. (författare)
  • Performance of the European Society of Cardiology 0/1-Hour, 0/2-Hour, and 0/3-Hour Algorithms for Rapid Triage of Acute Myocardial Infarction : An International Collaborative Meta-analysis
  • 2022
  • Ingår i: Annals of Internal Medicine. - 0003-4819. ; 175:1, s. 101-113
  • Forskningsöversikt (refereegranskat)abstract
    • BACKGROUND: The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI).PURPOSE: To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms.DATA SOURCES: PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479).STUDY SELECTION: Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI.DATA EXTRACTION: The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality.DATA SYNTHESIS: A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays.LIMITATION: Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies.CONCLUSION: The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI.PRIMARY FUNDING SOURCE: National Taiwan University Hospital.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy