SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Amin Sidra) "

Sökning: WFRF:(Amin Sidra)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Amin, Sidra, et al. (författare)
  • A practical non-enzymatic urea sensor based on NiCo 2 O 4 nanoneedles
  • 2019
  • Ingår i: RSC Advances. - : Royal Society of Chemistry. - 2046-2069. ; 9:25, s. 14443-14451
  • Tidskriftsartikel (refereegranskat)abstract
    • We propose a new facile electrochemical sensing platform for determination of urea, based on a glassy carbon electrode (GCE) modified with nickel cobalt oxide (NiCo 2 O 4 ) nanoneedles. These nanoneedles are used for the first time for highly sensitive determination of urea with the lowest detection limit (1 μM) ever reported for the non-enzymatic approach. The nanoneedles were grown through a simple and low-temperature aqueous chemical method. We characterized the structural and morphological properties of the NiCo 2 O 4 nanoneedles by TEM, SEM, XPS and XRD. The bimetallic nickel cobalt oxide exhibits nanoneedle morphology, which results from the self-assembly of nanoparticles. The NiCo 2 O 4 nanoneedles are exclusively composed of Ni, Co, and O and exhibit a cubic crystalline phase. Cyclic voltammetry was used to study the enhanced electrochemical properties of a NiCo 2 O 4 nanoneedle-modified GCE by overcoming the typical poor conductivity of bare NiO and Co 3 O 4 . The GCE-modified electrode is highly sensitive towards urea, with a linear response (R 2 = 0.99) over the concentration range 0.01-5 mM and with a detection limit of 1.0 μM. The proposed non-enzymatic urea sensor is highly selective even in the presence of common interferents such as glucose, uric acid, and ascorbic acid. This new urea sensor has good viability for urea analysis in urine samples and can represent a significant advancement in the field, owing to the simple and cost-effective fabrication of electrodes, which can be used as a promising analytical tool for urea estimation.
  •  
2.
  • Amin, Sidra, et al. (författare)
  • A practical non-enzymatic urea sensor based on NiCo2O4 nanoneedles
  • 2019
  • Ingår i: RSC Advances. - : Royal Society of Chemistry. - 2046-2069. ; 9:25, s. 14443-14451
  • Tidskriftsartikel (refereegranskat)abstract
    • We propose a new facile electrochemical sensing platform for determination of urea, based on a glassy carbon electrode (GCE) modified with nickel cobalt oxide (NiCo2O4) nanoneedles. These nanoneedles are used for the first time for highly sensitive determination of urea with the lowest detection limit (1 mu M) ever reported for the non-enzymatic approach. The nanoneedles were grown through a simple and low-temperature aqueous chemical method. We characterized the structural and morphological properties of the NiCo2O4 nanoneedles by TEM, SEM, XPS and XRD. The bimetallic nickel cobalt oxide exhibits nanoneedle morphology, which results from the self-assembly of nanoparticles. The NiCo2O4 nanoneedles are exclusively composed of Ni, Co, and O and exhibit a cubic crystalline phase. Cyclic voltammetry was used to study the enhanced electrochemical properties of a NiCo2O4 nanoneedle-modified GCE by overcoming the typical poor conductivity of bare NiO and Co3O4. The GCE-modified electrode is highly sensitive towards urea, with a linear response (R-2 = 0.99) over the concentration range 0.01-5 mM and with a detection limit of 1.0 mu M. The proposed non-enzymatic urea sensor is highly selective even in the presence of common interferents such as glucose, uric acid, and ascorbic acid. This new urea sensor has good viability for urea analysis in urine samples and can represent a significant advancement in the field, owing to the simple and cost-effective fabrication of electrodes, which can be used as a promising analytical tool for urea estimation.
  •  
3.
  • Amin, Sidra, et al. (författare)
  • A practical non-enzymatic urea sensor based on NiCo2O4 nanoneedles
  • 2019
  • Ingår i: RSC Advances. - : Royal Society of Chemistry. - 2046-2069. ; 9:25, s. 14443-14451
  • Tidskriftsartikel (refereegranskat)abstract
    • We propose a new facile electrochemical sensing platform for determination of urea, based on a glassy carbon electrode (GCE) modified with nickel cobalt oxide (NiCo2O4) nanoneedles. These nanoneedles are used for the first time for highly sensitive determination of urea with the lowest detection limit (1 μM) ever reported for the non-enzymatic approach. The nanoneedles were grown through a simple and low-temperature aqueous chemical method. We characterized the structural and morphological properties of the NiCo2O4 nanoneedles by TEM, SEM, XPS and XRD. The bimetallic nickel cobalt oxide exhibits nanoneedle morphology, which results from the self-assembly of nanoparticles. The NiCo2O4 nanoneedles are exclusively composed of Ni, Co, and O and exhibit a cubic crystalline phase. Cyclic voltammetry was used to study the enhanced electrochemical properties of a NiCo2O4 nanoneedle-modified GCE by overcoming the typical poor conductivity of bare NiO and Co3O4. The GCE-modified electrode is highly sensitive towards urea, with a linear response (R2 = 0.99) over the concentration range 0.01–5 mM and with a detection limit of 1.0 μM. The proposed non-enzymatic urea sensor is highly selective even in the presence of common interferents such as glucose, uric acid, and ascorbic acid. This new urea sensor has good viability for urea analysis in urine samples and can represent a significant advancement in the field, owing to the simple and cost-effective fabrication of electrodes, which can be used as a promising analytical tool for urea estimation.
  •  
4.
  • Amin, Sidra, et al. (författare)
  • A sensitive enzyme-free lactic acid sensor based on NiO nanoparticles for practical applications
  • 2019
  • Ingår i: Analytical Methods. - : Royal Society of Chemistry. - 1759-9660 .- 1759-9679. ; 11, s. 3578-3583
  • Tidskriftsartikel (refereegranskat)abstract
    • A facile and efficient electrochemical sensing platform has been successfully exploited for the first time for the determination of lactic acid using a nickel oxide (NiO) nanoparticle-modified glassy carbon electrode (GCE). Nickel oxide nanoparticles were prepared by a chemical growth method using different quantities of arginine as a soft template. The structural and morphological properties of NiO nanoparticles were characterized by Raman spectroscopy, scanning electron microscopy (SEM) and X-ray diffraction (XRD). Cyclic voltammetry (CV) was used to study the electrochemical properties of various samples. The modified electrode is highly sensitive and presents a linear response over a wide range (0.005–5 mM) of lactic acid concentrations in 0.1 M NaOH. The detection limit for the sensor was found to be 5.7 μM, and it exhibits good stability. Furthermore, the sensor shows excellent selectivity in the presence of common interfering species. The lactic acid sensor showed good viability for lactic acid analysis in real samples (milk, yogurt and red wine) and demonstrated significant advancement in sensor technology for practical applications.
  •  
5.
  • Amin, Sidra, et al. (författare)
  • Functional Nickel Oxide Nanostructures for Ethanol Oxidation in Alkaline Media
  • 2020
  • Ingår i: Electroanalysis. - : John Wiley & Sons. - 1040-0397 .- 1521-4109. ; 32:5, s. 1052-1059
  • Tidskriftsartikel (refereegranskat)abstract
    • Nickel oxide (NiO) nanostructures are employed in the basic medium for the oxidation of ethanol. A variety of NiO nanostructures are synthesized by wet chemical growth method, using different hydroxide (OH−) ion sources, particularly from ammonia, hexamethylenetetramine, urea and sodium hydroxide. The use of urea as (OH−) ion source results in flower‐like NiO structures composed by extremely thin nanowalls (thickness lower than 10 nm,), which demonstrated to be the most active for ethanol oxidation. All the samples exhibit NiO cubic phase, and no other impurity was detected. The cyclic voltammetry (CV) curves of NiO nanostructures were found linear over the concentration range 0.1–3.5 mM (R2=0.99) of ethanol, with the limit of detection estimated to be 0.013 mM for ethanol. The NiO nanostructures exhibit a selective signal towards ethanol oxidation in the presence of different members of alcohol family. The proposed NiO nanostructures showed a significant practicality for the reproducible and sensitive determination of ethanol from brandy, whisky, mixture of brandy and rum, and vodka samples. The nanomaterial was used as a surface modifying agent for the glassy carbon electrode and it showed a stable electro‐oxidation activity for the ethanol for 16 days. These findings indicate that the presented NiO nanomaterial can be applied in place of noble metals for ethanol sensing and other environmental applications (like fuel cells).
  •  
6.
  • Amin, Sidra, et al. (författare)
  • MoSx-Co3O4 Nanocomposite for Selective Determination of Ascorbic Acid
  • 2021
  • Ingår i: Journal of Nanoscience and Nanotechnology. - : AMER SCIENTIFIC PUBLISHERS. - 1533-4880 .- 1533-4899. ; 21:4, s. 2595-2603
  • Tidskriftsartikel (refereegranskat)abstract
    • Designing a nanocomposite with sensitive and selective determination of ascorbic acid is challenging task. It is possible through the exploitation of attractive features of nanoscience and nanotechnology for the synthesis of nanostructured materials. Herein, we report the decoration of nanoparticle of MoSx on the surface of Co3O4 nanowires by hydrothermal method. The MoSx nanoparticles shared the large surface on the Co3O4 nanowires, thus it supported in the development enzyme free ascorbic acid sensor. Non-enzymatic sensor based on MoSx-Co3O4 composite was found very selective for the determination of ascorbic acid (AA) in phosphate buffer solution of pH 7.4. The MoSx-Co3O4 nanocomposite was used to modify the glassy carbon electrode to measure AA from variety of practical samples. The MoSx-Co3O4 nanocomposite was used to modify the glassy carbon electrode and it has shown the attractive analytical features such as a low working potential +0.3 V, linear range of concentration from 100-7000 mu M, low limit of detection 14 mu M, and low limit of quantification (LOQ) of 42 mu M. The developed sensor is highly selective and stable. Importantly, it was applied successfully for the practical applications such as detection of AA from grapefruit, tomato and lemon juice. The excellent electrochemical properties of fabricated MoSx-Co3O4 nanocomposite can be attributed to the increasing electro active surface area of MoSx. The presented nanocomposite is earth abundant, environment friendly and inexpensive and it holds promising features for the selective and sensitive determination of AA from practical applications. The nanocomposite can be capitalized into the wide range of biomedical applications.
  •  
7.
  • Kumar, Raj, et al. (författare)
  • Synthesis of Sheet Like Morphology of NiO for Sensitive and Selective Determination of Urea
  • 2017
  • Ingår i: Sensor Letters. - : American Scientific Publishers. - 1546-198X .- 1546-1971. ; 15:10, s. 803-810
  • Tidskriftsartikel (refereegranskat)abstract
    • An efficient and simple method has been demonstrated for the synthesis of nickel oxide nanostructures using urea as a capping agent. The nanosheet-like morphology was confirmed by scanning electron microscopy, crystalline nature was studied by using the X-ray diffraction (XRD) and surface area of nanomaterial was investigated by automated sorption analyzer. Then synthesized NiO nanostructures were used to fabricate the surface of glassy carbon electrode (GCE). The electrocatalytic parameters of modified NiO/GCE electrode were investigated by using various techniques such as electrochemical impedance spectroscopy (EIS), square wave voltammetry (SWV), differential pulse voltammetry (DPV), normal pulse voltammetry (NPV) and cyclic voltammetry (CV) and chronoamperometry. Various working experimental conditions were optimized in order to attain the highest sensitivity for the determination of urea and the highest peak current 1032 μA of response were obtained at 100 μM concentration of urea. A linear calibration plot was obtained for peak current versus concentration of urea in the range of 10 μM urea to 80 μM urea with a good detection limit of 2 μM. The proposed working strategy was successfully employed for the estimation of urea in human urine samples and the obtained results are found satisfactory. The newly functional urea sensor can be exploited at large scale as an alternative analytical device beside to the other reported urea sensors
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy