SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Arfelli F.) "

Sökning: WFRF:(Arfelli F.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Peiffer, C., et al. (författare)
  • On the equivalence of the X-ray scattering retrieval with beam tracking and analyser-based imaging using a synchrotron source
  • 2023
  • Ingår i: Journal of Physics D. - : IOP Publishing. - 0022-3727 .- 1361-6463. ; 56:45
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray phase contrast imaging (XPCI) methods give access to contrast mechanisms that are based on the refractive properties of matter on top of the absorption coefficient in conventional x-ray imaging. Ultra small angle x-ray scattering (USAXS) is a phase contrast mechanism that arises due to multiple refraction events caused by physical features of a scale below the physical resolution of the used imaging system. USAXS contrast can therefore give insight into subresolution structural information, which is an ongoing research topic in the vast field of different XPCI techniques. In this study, we quantitatively compare the USAXS signal retrieved by the beam tracking XPCI technique with the gold standard of the analyzer based imaging XPCI technique using a synchrotron x-ray source. We find that, provided certain conditions are met, the two methods measure the same quantity.
  •  
2.
  • Perion, P., et al. (författare)
  • A high sensitivity wide bandwidth spectral system for multiple K-edge imaging
  • 2024
  • Ingår i: Journal of Physics D. - : IOP Publishing. - 0022-3727 .- 1361-6463. ; 57:35
  • Tidskriftsartikel (refereegranskat)abstract
    • Spectral K-edge subtraction (SKES) is an imaging technique that takes advantage of the sharp rise in the mass attenuation coefficient of specific elements within an object at their K-edge to produce separate and quantifiable distributions of each element. In this paper, a high-sensitivity and wide bandwidth SKES imaging system for computed tomography applications on biological samples is presented. X-ray images are acquired using a wide and continuous energy spectrum that encompasses the absorption edges of the target materials. System characterization shows that high energy resolution (approximately 3 × 10 − 3 ) and unprecedented large energy bandwidth (around 15%) are achieved over a field-of-view of several centimeters. Imaging results obtained on contrast elements relevant for biomedical applications, namely silver, iodine, xenon, and barium, demonstrate the system sensitivity to concentrations down to 0.5 mg ml−1. The achievement of a large energy bandwidth allowed the simultaneous imaging of the K-edges of iodine, xenon, and barium and provided an accurate concentration estimation and distinction of co-localized contrast elements, leading the way for future simultaneous cardiovascular (iodine), pulmonary (xenon), and gastrointestinal/inflammatory (barium) imaging applications. 
  •  
3.
  • Perion, P., et al. (författare)
  • Spectral micro-CT for simultaneous gold and iodine detection, and multi-material identification
  • 2024
  • Ingår i: Journal of Instrumentation. - : IOP Publishing. - 1748-0221. ; 19:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Multiple energy bin spectral micro-CT (SμCT) is an advanced imaging technique that allows multi-material decomposition according to their specific absorption patterns at a sub-100 μm scale. Typically, iodine is the preferred CT contrast agent for cardiovascular imaging, while gold nanoparticles have gained attention in recent years owing to their high absorption properties, biocompatibility and ability to target tumors. In this work, we demonstrate the potential for multi-material decomposition through SμCT imaging of a test sample at the PEPI lab of INFN Trieste. The sample, consisting of gold, iodine, calcium, and water, was imaged using a Pixirad1/PixieIII chromatic detector with multiple energy thresholds and a wide spectrum (100 kV) produced by a micro-focus X-ray tube. The results demonstrate the simultaneous detection and separation of the four materials at a spatial scale of 35 μm, suggesting the potential of this technique in improving material detectability and quantification in a range of pre-clinical applications, including cardiovascular and oncologic imaging. 
  •  
4.
  • Rodrigo Perez Vargas, J., et al. (författare)
  • Autofinding egg parasitoids in moth eggs by using machine learning methods in synchrotron-coherent X-ray imaging
  • 2024
  • Ingår i: Measurement. - : Elsevier BV. - 0263-2241 .- 1873-412X. ; 236
  • Tidskriftsartikel (refereegranskat)abstract
    • The use of a non-destructive technique, such as the propagation-based X-ray phase contrast radiography (PBR) can be an innovative method for automatic parasitism analysis, especially if it presents standard structures. Herein, an artificial intelligence (AI) model is applied in order to establish a computer vision of egg parasitoids in PBRs of parasitized moth eggs acquired at the Synchrotron Radiation for Medical Physics (SYRMEP) beamline at ELETTRA. PBRs of eggs parasitized in four different stages of parasitism (0 days, 3 days, 5 days and 7 days) have been tested. The AI model performance was evaluated by using different metrics. Average Precision (AP), which measures the accuracy of object detection, was found to be 0.866 and 0.741 for the moth eggs and for the parasites, respectively. Additionally, we found that as stage of parasitism becomes longer, the accuracy of parasitism detection also increases (76 % at 7 days).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy