SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Astrom J) "

Sökning: WFRF:(Astrom J)

  • Resultat 1-10 av 63
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Dahl, F, et al. (författare)
  • Imaging single DNA molecules for high precision NIPT
  • 2018
  • Ingår i: Scientific reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 8:1, s. 4549-
  • Tidskriftsartikel (refereegranskat)abstract
    • Cell-free DNA analysis is becoming adopted for first line aneuploidy screening, however for most healthcare programs, cost and workflow complexity is limiting adoption of the test. We report a novel cost effective method, the Vanadis NIPT assay, designed for high precision digitally-enabled measurement of chromosomal aneuploidies in maternal plasma. Reducing NIPT assay complexity is achieved by using novel molecular probe technology that specifically label target chromosomes combined with a new readout format using a nanofilter to enrich single molecules for imaging and counting without DNA amplification, microarrays or sequencing. The primary objective of this study was to assess the Vanadis NIPT assay with respect to analytical precision and clinical feasibility. Analysis of reference DNA samples indicate that samples which are challenging to analyze with low fetal-fraction can be readily detected with a limit of detection determined at <2% fetal-fraction. In total of 286 clinical samples were analysed and 30 out of 30 pregnancies affected by trisomy 21 were classified correctly. This method has the potential to make cost effective NIPT more widely available with more women benefiting from superior detection and false positive rates.
  •  
7.
  • Ahlström, Aisling, 1976, et al. (författare)
  • A double-blind randomized controlled trial investigating a time-lapse algorithm for selecting Day 5 blastocysts for transfer
  • 2022
  • Ingår i: Human Reproduction. - : Oxford University Press (OUP). - 0268-1161 .- 1460-2350. ; 37:4, s. 708-717
  • Tidskriftsartikel (refereegranskat)abstract
    • STUDY QUESTION Can use of a commercially available time-lapse algorithm for Day 5 blastocyst selection improve pregnancy rates compared with morphology alone? SUMMARY ANSWER The use of a time-lapse selection model to choose blastocysts for fresh single embryo transfer on Day 5 did not improve ongoing pregnancy rate compared to morphology alone. WHAT IS KNOWN ALREADY Evidence from time-lapse monitoring suggests correlations between timing of key developmental events and embryo viability. No good quality evidence exists to support improved pregnancy rates following time-lapse selection. STUDY DESIGN, SIZE, DURATION A prospective multicenter randomized controlled trial including 776 randomized patients was performed between 2018 and 2021. Patients with at least two good quality blastocysts on Day 5 were allocated by a computer randomization program in a proportion of 1:1 into either the control group, whereby single blastocysts were selected for transfer by morphology alone, or the intervention group whereby final selection was decided by a commercially available time-lapse model. The embryologists at the time of blastocyst morphological scoring were blinded to which study group the patients would be randomized, and the physician and patients were blind to which group they were allocated until after the primary outcome was known. The primary outcome was number of ongoing pregnancies in the two groups. PARTICIPANTS/MATERIALS, SETTING, METHODS From 10 Nordic IVF clinics, 776 patients with a minimum of two good quality blastocysts on Day 5 (D5) were randomized into one of the two study groups. A commercial time-lapse model decided the final selection of blastocysts for 387 patients in the intervention (time-lapse) group, and blastocysts with the highest morphological score were transferred for 389 patients in the control group. Only single embryo transfers in fresh cycles were performed. MAIN RESULTS AND THE ROLE OF CHANCE In the full analysis set, the ongoing pregnancy rate for the time-lapse group was 47.4% (175/369) and 48.1% (181/376) in the control group. No statistically significant difference was found between the two groups: mean difference -0.7% (95% CI -8.2, 6.7, P = 0.90). Pregnancy rate (60.2% versus 59.0%, mean difference 1.1%, 95% CI -6.2, 8.4, P = 0.81) and early pregnancy loss (21.2% versus 18.5%, mean difference 2.7%, 95% CI -5.2, 10.6, P = 0.55) were the same for the time-lapse and the control group. Subgroup analyses showed that patient and treatment characteristics did not significantly affect the commercial time-lapse model D5 performance. In the time-lapse group, the choice of best blastocyst changed on 42% of occasions (154/369, 95% CI 36.9, 47.2) after the algorithm was applied, and this rate was similar for most treatment clinics. LIMITATIONS, REASONS FOR CAUTION During 2020, the patient recruitment rate slowed down at participating clinics owing to coronavirus disease-19 restrictions, so the target sample size was not achieved as planned and it was decided to stop the trial prematurely. The study only investigated embryo selection at the blastocyst stage on D5 in fresh IVF transfer cycles. In addition, only blastocysts of good morphological quality were considered for transfer, limiting the number of embryos for selection in both groups: also, it could be argued that this manual preselection of blastocysts limits the theoretical selection power of time-lapse, as well as restricting the results mainly to a good prognosis patient group. Most patients were aimed for blastocyst stage transfer when a minimum of five zygotes were available for extended culture. Finally, the primary clinical outcome evaluated was pregnancy to only 6-8 weeks. WIDER IMPLICATIONS OF THE FINDINGS The study suggests that time-lapse selection with a commercially available time-lapse model does not increase chance of ongoing pregnancy after single blastocyst transfer on Day 5 compared to morphology alone. STUDY FUNDING/COMPETING INTEREST(S) The study was financed by a grant from the Swedish state under the ALF-agreement between the Swedish government and the county councils (ALFGBG-723141). Vitrolife supported the study with embryo culture dishes and culture media. During the study period, T.H. changed his employment from Livio AB to Vitrolife AB. All other authors have no conflicts of interests to disclose. DATE OF FIRST PATIENT'S ENROLMENT 11 June 2018.
  •  
8.
  •  
9.
  •  
10.
  • Garcia, J, et al. (författare)
  • ECG-based detection of body position changes in ischemia monitoring
  • 2003
  • Ingår i: IEEE Transactions on Biomedical Engineering. - 1558-2531. ; 50:6, s. 677-685
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this gaper is to analyze and detect changes in body position (BPC) during electrocardiogram (ECG) recording. These changes are often manifested as shifts in the, electrical axis and may be misclassified as ischemic changes during. ambulatory monitoring. We investigate two ECG signal processing methods for detecting BPCs. Different schemes for feature extraction are used (spatial and scalar), while preprocessing, trend postprocessing and detection are identical. The spatial approach is based on VCG loop rotation angles and the scalar approach is based on the Karhunen-Loeve transform (KLT) coefficients. The methods are evaluated on two different databases: a database with annotated BPCs and the STAFF III database with recordings from rest and during angioplasty-induced ischemia but not including BPCs. The angle-based detector results in performance values of detection probability P-D = 95%, false alarm probability P-F = 3% in the BPC database and false alarm rate in the STAFF III database in control ECCs during rest R-F(c) = 2 h(-1) (episodes per hour) and in ischemia recordings during angioplasty R-F(a) = 7 h(-1), whereas the KLT-based detector produces values of P-D = 89%, P-F = 3%, R-F(c) = 4 h(-1), and RF(a) = 11 h-1, respectively. Including information on noise level in the detection process to reduce the number of false alarms, performance values of P-D similar or equal to 90%, P-F similar or equal to 1%, R-F(c) similar or equal to 1 h(-1) and R-F(a) similar or equal to 2 h(-1) are obtained with both methods. It is concluded that reliable detection of BPCs may be achieved using the ECG signal and should work in parallel to ischemia detectors.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 63

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy