SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Athan Eugene) "

Sökning: WFRF:(Athan Eugene)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Athan, Eugene, et al. (författare)
  • Clinical characteristics and outcome of infective endocarditis involving implantable cardiac devices
  • 2012
  • Ingår i: JAMA - Journal of the American Medical Association. - : American Medical Association (AMA). - 0098-7484 .- 1538-3598. ; 307, s. 1727-1735
  • Tidskriftsartikel (refereegranskat)abstract
    • Context: Infection of implantable cardiac devices is an emerging disease with significant morbidity, mortality, and health care costs. Objectives: To describe the clinical characteristics and outcome of cardiac device infective endocarditis (CDIE) with attention to its health care association and to evaluate the association between device removal during index hospitalization and outcome. Design, Setting, and Patients: Prospective cohort study using data from the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), conducted June 2000 through August 2006 in 61 centers in 28 countries. Patients were hospitalized adults with definite endocarditis as defined by modified Duke endocarditis criteria. Main Outcome Measures: In-hospital and 1-year mortality. Results: CDIE was diagnosed in 177 (6.4% [95% CI, 5.5%-7.4%]) of a total cohort of 2760 patients with definite infective endocarditis. The clinical profile of CDIE included advanced patient age (median, 71.2 years [interquartile range, 59.8-77.6]); causation by staphylococci (62 [35.0% {95% CI, 28.0%-42.5%}] Staphylococcus aureus and 56 [31.6% {95% CI, 24.9%-39.0%}] coagulase-negative staphylococci); and a high prevalence of health care-associated infection (81 [45.8% {95% CI, 38.3%- 53.4%}]). There was coexisting valve involvement in 66 (37.3% [95% CI, 30.2%- 44.9%]) patients, predominantly tricuspid valve infection (43/177 [24.3%]), with associated higher mortality. In-hospital and 1-year mortality rates were 14.7% (26/177 [95% CI, 9.8%-20.8%]) and 23.2% (41/177 [95% CI, 17.2%-30.1%]), respectively. Proportional hazards regression analysis showed a survival benefit at 1 year for device removal during the initial hospitalization (28/141 patients [19.9%] who underwent device removal during the index hospitalization had died at 1 year, vs 13/34 [38.2%] who did not undergo device removal; hazard ratio, 0.42 [95% CI, 0.22- 0.82]). Conclusions: Among patients with CDIE, the rate of concomitant valve infection is high, as is mortality, particularly if there is valve involvement. Early device removal is associated with improved survival at 1 year. ©2012 American Medical Association. All rights reserved.
  •  
2.
  •  
3.
  •  
4.
  • Oostvogels, Lidia, et al. (författare)
  • Medical conditions at enrollment do not impact efficacy and safety of the adjuvanted recombinant zoster vaccine : a pooled post-hoc analysis of two parallel randomized trials
  • 2019
  • Ingår i: Human Vaccines & Immunotherapeutics. - : Informa UK Limited. - 2164-5515 .- 2164-554X. ; 15:12, s. 2865-2872
  • Tidskriftsartikel (refereegranskat)abstract
    • In two pivotal efficacy studies (ZOE-50; ZOE-70), the adjuvanted recombinant zoster vaccine (RZV) demonstrated >90% efficacy against herpes zoster (HZ). Adults aged >= 50 or >= 70 years (ZOE-50 [NCT01165177]; ZOE-70 [NCT01165229]) were randomized to receive 2 doses of RZV or placebo 2 months apart. Vaccine efficacy and safety were evaluated post-hoc in the pooled (ZOE-50/70) population according to the number and type of selected medical conditions present at enrollment. At enrollment, 82.3% of RZV and 82.7% of placebo recipients reported >= 1 of the 15 selected medical conditions. Efficacy against HZ ranged from 84.5% (95% Confidence Interval [CI]: 46.4-97.1) in participants with respiratory disorders to 97.0% (95%CI: 82.3-99.9) in those with coronary heart disease. Moreover, efficacy remained >90% irrespective of the number of selected medical conditions reported by a participant. As indicated by the similarity of the point estimates, this post-hoc analysis suggests that RZV efficacy remains high in all selected medical conditions, as well as with increasing number of medical conditions. No safety concern was identified by the type or number of medical conditions present at enrollment.
  •  
5.
  • Wang, Andrew, et al. (författare)
  • Contemporary clinical profile and outcome of prosthetic valve endocarditis.
  • 2007
  • Ingår i: JAMA : the journal of the American Medical Association. - : American Medical Association (AMA). - 1538-3598. ; 297:12, s. 1354-61
  • Tidskriftsartikel (refereegranskat)abstract
    • CONTEXT: Prosthetic valve endocarditis (PVE) is associated with significant mortality and morbidity. The contemporary clinical profile and outcome of PVE are not well defined. OBJECTIVES: To describe the prevalence, clinical characteristics, and outcome of PVE, with attention to health care-associated infection, and to determine prognostic factors associated with in-hospital mortality. DESIGN, SETTING, AND PARTICIPANTS: Prospective, observational cohort study conducted at 61 medical centers in 28 countries, including 556 patients with definite PVE as defined by Duke University diagnostic criteria who were enrolled in the International Collaboration on Endocarditis-Prospective Cohort Study from June 2000 to August 2005. MAIN OUTCOME MEASURE: In-hospital mortality. RESULTS: Definite PVE was present in 556 (20.1%) of 2670 patients with infective endocarditis. Staphylococcus aureus was the most common causative organism (128 patients [23.0%]), followed by coagulase-negative staphylococci (94 patients [16.9%]). Health care-associated PVE was present in 203 (36.5%) of the overall cohort. Seventy-one percent of health care-associated PVE occurred within the first year of valve implantation, and the majority of cases were diagnosed after the early (60-day) period. Surgery was performed in 272 (48.9%) patients during the index hospitalization. In-hospital death occurred in 127 (22.8%) patients and was predicted by older age, health care-associated infection (62/203 [30.5%]; adjusted odds ratio [OR], 1.62; 95% confidence interval [CI], 1.08-2.44; P = .02), S aureus infection (44/128 [34.4%]; adjusted OR, 1.73; 95% CI, 1.01-2.95; P = .05), and complications of PVE, including heart failure (60/183 [32.8%]; adjusted OR, 2.33; 95% CI, 1.62-3.34; P<.001), stroke (34/101 [33.7%]; adjusted OR, 2.25; 95% CI, 1.25-4.03; P = .007), intracardiac abscess (47/144 [32.6%]; adjusted OR, 1.86; 95% CI, 1.10-3.15; P = .02), and persistent bacteremia (27/49 [55.1%]; adjusted OR, 4.29; 95% CI, 1.99-9.22; P<.001). CONCLUSIONS: Prosthetic valve endocarditis accounts for a high percentage of all cases of infective endocarditis in many regions of the world. Staphylococcus aureus is now the leading cause of PVE. Health care-associated infection significantly influences the clinical characteristics and outcome of PVE. Complications of PVE strongly predict in-hospital mortality, which remains high despite prompt diagnosis and the frequent use of surgical intervention.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy