SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Aydin Schmidt Berit) "

Sökning: WFRF:(Aydin Schmidt Berit)

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aydin-Schmidt, Berit, et al. (författare)
  • Carolus Linnaeus, the ash, worm-wood and other anti-malarial plants
  • 2010
  • Ingår i: Scandinavian Journal of Infectious Diseases. - : Informa UK Limited. - 0036-5548 .- 1651-1980. ; 42:11-12, s. 941-942
  • Tidskriftsartikel (refereegranskat)abstract
    • In 1735 Carolus Linnaeus wrote that quinine was the preferred treatment for malaria but that the bark of the ash (Fraxinus excelsior) and worm-wood (Artemisia absinthium) also had effects on the disease. We here report that lipo- and hydrophilic extracts of the bark of the ash inhibit the in vitro growth of the asexual stages of P. falciparum. The data suggests that the knowledge of the treatment of malaria was already available in Europe some 300 years ago.
  •  
2.
  • Aydin-Schmidt, Berit, et al. (författare)
  • Field Evaluation of a High Throughput Loop Mediated Isothermal Amplification Test for the Detection of Asymptomatic Plasmodium Infections in Zanzibar
  • 2017
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background New field applicable diagnostic tools are needed for highly sensitive detection of residual malaria infections in pre-elimination settings. Field performance of a high throughput DNA extraction system for loop mediated isothermal amplification (HTP-LAMP) was therefore evaluated for detecting malaria parasites among asymptomatic individuals in Zanzibar. Methods HTP-LAMP performance was evaluated against real-time PCR on 3008 paired blood samples collected on filter papers in a community-based survey in 2015. Results The PCR and HTP-LAMP determined malaria prevalences were 1.6% (95% CI 1.3-2.4) and 0.7% (95% CI 0.4-1.1), respectively. The sensitivity of HTP-LAMP compared to PCR was 40.8% (CI95% 27.0-55.8) and the specificity was 99.9% (CI95% 99.8-100). For the PCR positive samples, there was no statistically significant difference between the geometric mean parasite densities among the HTP-LAMP positive (2.5 p/mu L, range 0.2-770) and HTP-LAMP negative (1.4 p/mu L, range 0.1-7) samples (p = 0.088). Two lab technicians analysed up to 282 samples per day and the HTP-LAMP method was experienced as user friendly. Conclusions Although field applicable, this high throughput format of LAMP as used here was not sensitive enough to be recommended for detection of asymptomatic low-density infections in areas like Zanzibar, approaching malaria elimination.
  •  
3.
  • Aydin-Schmidt, Berit, et al. (författare)
  • Loop mediated isothermal amplification (LAMP) accurately detects malaria DNA from filter paper blood samples of low density parasitaemias
  • 2014
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 9:8, s. e103905-
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Loop mediated isothermal amplification (LAMP) provides an opportunity for improved, field-friendly detection of malaria infections in endemic areas. However data on the diagnostic accuracy of LAMP for active case detection, particularly low-density parasitaemias, are lacking. We therefore evaluated the performance of a new LAMP kit compared with PCR using DNA from filter paper blood spots.METHODS AND FINDINGS:Samples from 865 fever patients and 465 asymptomatic individuals collected in Zanzibar were analysed for Pan (all species) and Pf (P. falciparum) DNA with the Loopamp MALARIA Pan/Pf kit. Samples were amplified at 65°C for 40 minutes in a real-time turbidimeter and results were compared with nested PCR. Samples with discordant results between LAMP and nested PCR were analysed with real-time PCR. The real-time PCR corrected nested PCR result was defined as gold standard. Among the 117 (13.5%) PCR detected P. falciparum infections from fever patients (mean parasite density 7491/µL, range 6-782,400) 115, 115 and 111 were positive by Pan-LAMP, Pf-LAMP and nested PCR, respectively. The sensitivities were 98.3% (95%CI 94-99.8) for both Pan and Pf-LAMP. Among the 54 (11.6%) PCR positive samples from asymptomatic individuals (mean parasite density 10/µL, range 0-4972) Pf-LAMP had a sensitivity of 92.7% (95%CI 80.1-98.5) for detection of the 41 P. falciparum infections. Pan-LAMP had sensitivities of 97% (95%CI 84.2-99.9) and 76.9% (95%CI 46.2-95) for detection of P. falciparum and P. malariae, respectively. The specificities for both Pan and Pf-LAMP were 100% (95%CI 99.1-100) in both study groups.CONCLUSION:Both components of the Loopamp MALARIA Pan/Pf detection kit revealed high diagnostic accuracy for parasite detection among fever patients and importantly also among asymptomatic individuals of low parasite densities from minute blood volumes preserved on filter paper. These data support LAMPs potential role for improved detection of low-density malaria infections in pre-elimination settings.
  •  
4.
  • Aydin Schmidt, Berit (författare)
  • New diagnostic tools for malaria-challenges and opportunities
  • 2014
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Nearly half of the world’s population is at risk for malaria and over 600,000 die from the disease every year. Access to prompt and correct parasite based diagnosis in order to target treatment to those with a confirmed malaria infection and improved malaria surveillance are cornerstones in malaria control. The availability of modern diagnostic tools such as rapid diagnostic test (RDT), polymerase chain reaction (PCR) and loop mediated isothermal amplification (LAMP) represent new opportunities besides microscopy for improved sensitive and accurate parasite-based diagnosis. However, there are different demands on diagnostic tools for different health care settings and endemic contexts. The performance of RDT was compared to blood smear microscopy and PCR among febrile patients in a low endemic/pre elimination area (Zanzibar). Although the sensitivity of RDT was found to be relatively low (76.5%) the health care workers were highly adherent to test results in prescribing antimalarial drugs. Parasite clearance and detection of recurrent infections was assessed by different diagnostic methods after malaria treatment in febrile children in a relatively high endemic area of mainland Tanzania. Median clearance time was two days for PCR and microscopy whereas the clearance times were seven and 28 days for the pLDH and HRP2 based RDTs, respectively. pLDH based RDT was a better tool than HRP2 based for treatment follow up and detection of recurrent infection. The usefulness of RDT as a source of parasite DNA was evaluated through different parasite DNA extraction methods. DNA extraction efficacy varied with test device and extraction method. There was no difference in PCR detection rates between RDT and filter paper samples collected from the field. This confirms the usefulness of RDTs stored under field conditions as a modern tool for molecular malaria surveillance and RDT quality control. A LAMP kit was compared to conventional PCR methods for detection of parasite DNA from dried blood spots collected among both fever patients and asymptomatic individuals in Zanzibar. The LAMP kit had a sensitivity of 98% for detection of Plasmodium(P) falciparum among fever patients and a sensitivity of > 92% and 77% for detection of P. falciparum and P. malariae among asymptomatic individuals. The high diagnostic accuracy of the LAMP kit for detection of low density parasitaemias from minute blood volumes preserved on filter papers supports its role for improved case detection in areas of low density malaria infections. The results in this thesis provide important data on the usefulness of new diagnostic tools for improved case detection and surveillance of malaria in different endemic contexts.
  •  
5.
  • Aydin-Schmidt, Berit, et al. (författare)
  • Usefulness of Plasmodium falciparum-specific rapid diagnostic tests for assessment of parasite clearance and detection of recurrent infections after artemisinin-based combination therapy.
  • 2013
  • Ingår i: Malaria journal. - : Springer Science and Business Media LLC. - 1475-2875. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Rapid diagnostic test (RDT) is an important tool for parasite-based malaria diagnosis. High specificity of RDTs to distinguish an active Plasmodium falciparum infection from residual antigens from a previous infection is crucial in endemic areas where residents are repeatedly exposed to malaria. The efficiency of two RDTs based on histidine-rich protein 2 (HRP2) and lactate dehydrogenase (LDH) antigens were studied and compared with two microscopy techniques (Giemsa and acridine orange-stained blood smears) and real-time polymerase chain reaction (PCR) for assessment of initial clearance and detection of recurrent P. falciparum infections after artemisinin-based combination therapy (ACT) in a moderately high endemic area of rural Tanzania.
  •  
6.
  • Cook, Jackie, et al. (författare)
  • Loop-mediated isothermal amplification (LAMP) for point-of-care detection of asymptomatic low-density malaria parasite carriers in Zanzibar
  • 2015
  • Ingår i: Malaria Journal. - : Springer Science and Business Media LLC. - 1475-2875 .- 1475-2875. ; 14, s. 43-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Asymptomatic, low parasite density malaria infections are difficult to detect with currently available point-of-care diagnostics. This study piloted a loop-mediated isothermal amplification (LAMP) kit for field-friendly, high-throughput detection of asymptomatic malaria infections during mass screening and treatment (MSAT) in Zanzibar, a malaria pre-elimination setting. Methods: Screening took place in three known hotspot areas prior to the short rains in November. Finger-prick blood was taken for screening by rapid diagnostic test (RDT) and LAMP and collected on filter paper for subsequent polymerase chain reaction (PCR) analyses. LAMP results were compared to RDT and to PCR using McNemar's test. Results: Approximately 1,000 people were screened. RDT detected ten infections (1.0% (95% CI 0.3-1.6)) whilst both LAMP and PCR detected 18 (1.8% (95% CI 0.9-2.6)) infections. However, PCR identified three infections that LAMP did not detect and vice versa. LAMP testing was easy to scale-up in field conditions requiring minimal training and equipment, with results ready one to three hours after screening. Conclusions: Despite lower than expected prevalence, LAMP detected a higher number of infections than the currently used diagnostic, RDT. LAMP is a field-friendly, sensitive diagnostic test that could be useful for MSAT malaria campaigns which require quick results to enable prompt treatment.
  •  
7.
  • Holmström, Oscar, et al. (författare)
  • A novel deep learning-based point-of-care diagnostic method for detecting Plasmodium falciparum with fluorescence digital microscopy.
  • 2020
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 15:11
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Malaria remains a major global health problem with a need for improved field-usable diagnostic tests. We have developed a portable, low-cost digital microscope scanner, capable of both brightfield and fluorescence imaging. Here, we used the instrument to digitize blood smears, and applied deep learning (DL) algorithms to detect Plasmodium falciparum parasites.METHODS: Thin blood smears (n = 125) were collected from patients with microscopy-confirmed P. falciparum infections in rural Tanzania, prior to and after initiation of artemisinin-based combination therapy. The samples were stained using the 4',6-diamidino-2-phenylindole fluorogen and digitized using the prototype microscope scanner. Two DL algorithms were trained to detect malaria parasites in the samples, and results compared to the visual assessment of both the digitized samples, and the Giemsa-stained thick smears.RESULTS: Detection of P. falciparum parasites in the digitized thin blood smears was possible both by visual assessment and by DL-based analysis with a strong correlation in results (r = 0.99, p < 0.01). A moderately strong correlation was observed between the DL-based thin smear analysis and the visual thick smear-analysis (r = 0.74, p < 0.01). Low levels of parasites were detected by DL-based analysis on day three following treatment initiation, but a small number of fluorescent signals were detected also in microscopy-negative samples.CONCLUSION: Quantification of P. falciparum parasites in DAPI-stained thin smears is feasible using DL-supported, point-of-care digital microscopy, with a high correlation to visual assessment of samples. Fluorescent signals from artefacts in samples with low infection levels represented the main challenge for the digital analysis, thus highlighting the importance of minimizing sample contaminations. The proposed method could support malaria diagnostics and monitoring of treatment response through automated quantification of parasitaemia and is likely to be applicable also for diagnostics of other Plasmodium species and other infectious diseases.
  •  
8.
  • Mhamilawa, Lwidiko E, et al. (författare)
  • Detection of Plasmodium falciparum by Light Microscopy, Loop-Mediated Isothermal Amplification, and Polymerase Chain Reaction on Day 3 after Initiation of Artemether-Lumefantrine Treatment for Uncomplicated Malaria in Bagamoyo District, Tanzania : A Comparative Trial
  • 2019
  • Ingår i: American Journal of Tropical Medicine and Hygiene. - : American Society of Tropical Medicine and Hygiene. - 0002-9637 .- 1476-1645. ; 101:5, s. 1144-1147
  • Tidskriftsartikel (refereegranskat)abstract
    • Microscopy-determined Plasmodium falciparum positivity rates exceeding 10% on day 3 after initiation of artemisinin-based combination therapy (ACT) is an important indicator of artemisinin resistance. However, microscopy does not detect low-density parasitemia, contrary to molecular tools such as loop-mediated isothermal amplification (LAMP) and polymerase chain reaction (PCR). We compared microscopy, LAMP, and PCR for detection of P. falciparum on day 3 after ACT in 256 patients with uncomplicated malaria in Bagamoyo District, Tanzania. Day 3 positivity rates were 0%, 84.8%, and 84.4% for each method, respectively. The sensitivity and specificity of LAMP against PCR was 100% (95% CI, 96.1-100) and 77.4% (95% CI, 58.9-90.4) when quantitative PCR-determined parasite densities were ≥ two parasites/µL. Loop-mediated isothermal amplification had comparable diagnostic accuracy to PCR and could potentially represent a field-friendly tool for determining day 3 positivity rates. However, what day 3 P. falciparum positivity determined using molecular methods represents needs to be further elucidated.
  •  
9.
  • Morris, Ulrika, et al. (författare)
  • A cluster randomised controlled trial of two rounds of mass drug administration in Zanzibar, a malaria pre-elimination setting-high coverage and safety, but no significant impact on transmission.
  • 2018
  • Ingår i: BMC Medicine. - : Springer Science and Business Media LLC. - 1741-7015. ; 16:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Mass drug administration (MDA) has the potential to interrupt malaria transmission and has been suggested as a tool for malaria elimination in low-endemic settings. This study aimed to determine the effectiveness and safety of two rounds of MDA in Zanzibar, a pre-elimination setting.METHODS: A cluster randomised controlled trial was conducted in 16 areas considered as malaria hotspots, with an annual parasite index of > 0.8%. The areas were randomised to eight intervention and eight control clusters. The intervention included two rounds of MDA with dihydroartemisinin-piperaquine and single low-dose primaquine 4 weeks apart in May-June 2016. Primary and secondary outcomes were cumulative confirmed malaria case incidences 6 months post-MDA and parasite prevalences determined by PCR 3 months post-MDA. Additional outcomes included intervention coverage, treatment adherence, occurrence of adverse events, and cumulative incidences 3, 12, and 16 months post-MDA.RESULTS: Intervention coverage was 91.0% (9959/10944) and 87.7% (9355/10666) in the first and second rounds, respectively; self-reported adherence was 82.0% (881/1136) and 93.7% (985/1196). Adverse events were reported in 11.6% (147/1268) and 3.2% (37/1143) of post-MDA survey respondents after both rounds respectively. No serious adverse event was reported. No difference in cumulative malaria case incidence was observed between the control and intervention arms 6 months post-MDA (4.2 and 3.9 per 1000 population; p = 0.94). Neither was there a difference in PCR-determined parasite prevalences 3 months post-MDA (1.4% and 1.7%; OR = 1.0, p = 0.94), although having received at least the first MDA was associated with reduced odds of malaria infection (aOR = 0.35; p = 0.02). Among confirmed malaria cases at health facilities, 26.0% and 26.3% reported recent travel outside Zanzibar in the intervention and control shehias (aOR ≥ 85; p ≤ 0.001).CONCLUSIONS: MDA was implemented with high coverage, adherence, and tolerability. Despite this, no significant impact on transmission was observed. The findings suggest that two rounds of MDA in a single year may not be sufficient for a sustained impact on transmission in a pre-elimination setting, especially when the MDA impact is restricted by imported malaria. Importantly, this study adds to the limited evidence for the use of MDA in low transmission settings in sub-Saharan Africa.TRIAL REGISTRATION: ClinicalTrials.gov, NCT02721186 (registration date: March 29, 2016).
  •  
10.
  • Morris, Ulrika, et al. (författare)
  • Field deployment of loop-mediated isothermal amplification for centralized mass-screening of asymptomatic malaria in Zanzibar : a pre-elimination setting
  • 2015
  • Ingår i: Malaria Journal. - : Springer Science and Business Media LLC. - 1475-2875 .- 1475-2875. ; 14
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Molecular tools for detection of low-density asymptomatic Plasmodium infections are needed in malaria elimination efforts. This study reports results from the hitherto largest implementation of loop-mediated isothermal amplification (LAMP) for centralized mass screening of asymptomatic malaria in Zanzibar.METHODS: Healthy individuals present and willing to participate in randomly selected households in 60 villages throughout Zanzibar were screened for malaria by rapid diagnostic tests (RDT). In 50 % of the study households, participants were asked to provide 60 μL of finger-prick blood for additional LAMP screening. LAMP was conducted in two centralized laboratories in Zanzibar, by trained technicians with limited or no previous experience of molecular methods. The LAMP assay was performed with Loopamp(TM) MALARIA Pan/Pf Detection Kit (Eiken Chemical Company, Japan). Samples positive for Plasmodium genus (Pan)-LAMP were re-tested using Plasmodium falciparum-specific LAMP kits.RESULTS: Paired RDT and LAMP samples were available from 3983 individuals. The prevalence of asymptomatic malaria was 0.5 % (CI 95 % 0.1-0.8) and 1.6 % (CI 95 % 1.1-2.2) by RDT and Pan-LAMP, respectively. LAMP detected 3.4 (CI 95 % 2.2-5.2) times more Plasmodium positive samples than RDT. DNA contamination was experienced, but solved by repetitive decontamination of all equipment and reagents.CONCLUSIONS: LAMP is a simple and sensitive molecular tool, and has potential in active surveillance and mass-screening programmes for detection of low-density asymptomatic malaria in pre-elimination settings. However, in order to deploy LAMP more effectively in field settings, protocols may need to be adapted for processing larger numbers of samples. A higher throughput, affordable closed system would be ideal to avoid contamination.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy