SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bäck Anna Karin 1971 ) "

Sökning: WFRF:(Bäck Anna Karin 1971 )

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bäck, Anna-Karin, 1971-, et al. (författare)
  • Renography with a semiautomated algorithm for diuretic decision 7 min postradiopharmaceutical administration : a feasibility study
  • 2020
  • Ingår i: Nuclear medicine communications. - : Lippincott Williams & Wilkins. - 0143-3636 .- 1473-5628. ; 41:10, s. 1018-1025
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The F+10 method for diuretic renography (diuretics given 10 min after the radiopharmaceutical) could be a time-conserving method. This method involves a 30-min dynamic acquisition where diuretics are administered only when necessary by the Nuclear Medicine technologist performing the examination. The purpose of this study was to assess the method's performance and to discover the optimal threshold of residual activity for a diuretic administration 7 min into the F+10 renography by reprocessing raw data from prior performed examinations with 20-min acquisitions without diuretics.METHODS: Retrospectively, raw data from 320 original examinations of adult patients performed from 2013 to 2015 were reprocessed into 7-min series and categorized as requiring diuretic or not. The diuretic decisions made by an expert panel were used as a reference. A receiver-operating characteristic curve was drawn to assess the optimal cutoff value for the residual renal activity. Sensitivity, specificity, positive and negative predictive values, as well as the Youden J index were calculated.RESULT: The experts classified 50% (160 examinations) as in need of diuretics. The receiver-operating characteristic curve demonstrated the theoretical optimal cutoff value at 7 min to be 94% of maximum activity (sensitivity 0.93, specificity 0.81, Youden J index 0.73). A clinically acceptable threshold is suggested to be 85% (sensitivity 0.99, specificity 0.59, Youden J index 0.58).CONCLUSION: Tc-mercaptoacetyltriglycine renography with the F+10 method and the threshold 85% for diuretic decision 7 min into the renography is a feasible and acceptable method in clinical practice.
  •  
2.
  • Bäck, Anna-Karin, 1971-, et al. (författare)
  • Timing of diuretics in diuresis renography
  • 2022
  • Ingår i: Clinical and translational imaging. - : Springer. - 2281-5872 .- 2281-7565. ; 10, s. 37-43
  • Forskningsöversikt (refereegranskat)abstract
    • Purpose: The aim of this systematic literature review was to obtain an overview of when to administer the diuretics in relation to the radiopharmaceutical during a diuresis renography.Methods: A systematic literature search was performed in three different databases (Embase, PubMed/Medline and Cochrane Library) together with an information specialist. The review question was: when should diuretics be administered in relation to the radiopharmaceutical in a diuresis renography? Studies of adults were included together with guidelines published in collaboration with an organization.Results: Seventeen articles and four guidelines were retrieved in the literature search. The F - 15 method (diuretics administered 15 min before the radiopharmaceutical) was the one that was studied and described most and was compared with other time points for diuretic administration. The retrieved articles and guidelines report of advantages with different time points for diuretics. Both F - 15 and F + 0 are reported to clarify washout in equivocal cases compared to F + 20.Conclusion: No consensus could be found for a preferred time point of diuretics administration during a diuresis renography.
  •  
3.
  • Bäck, Anna-Karin, 1971-, et al. (författare)
  • Troubled but in good hands : A qualitative study on patient experiences in diuresis renography examinations
  • 2024
  • Ingår i: Radiography. - : Elsevier. - 1078-8174 .- 1532-2831.
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Diuresis renography is a nuclear medicine examination that can distinguish between obstructive and non-obstructive uropathy. Renography has been investigated before, but not from a patient perspective. The aim of this study was to gain knowledge and understanding of patient experiences with the diuresis renography process.METHODS: The study had a qualitative descriptive design; data was collected through semi-structured interviews with 17 adult patients that had recently undergone diuresis renography. The transcripts were analysed using inductive qualitative content analysis to identify their manifest and latent content.RESULTS: One main theme was identified: 'Not smooth all the way through, but still in good hands'. The participants understood the necessity of the performed renography and endured the examination despite its worrying elements. They were bothered by diuretic effects, worried about radioactivity and felt isolated during the imaging. The technologists' caring and informative approach eased their experience. The main theme was identified from three subthemes: 'I experienced inconvenience', 'I was worried' and 'I felt safe'.CONCLUSION: The participants experienced worry throughout the renography process but were still satisfied with the examination, mostly because of the technologists being involved. Communication and interaction between patient and technologist are important for creating a good experience. Improved knowledge of patient experiences during renographies could be used to develop patient information and increase technologists' awareness of factors patients may experience as troubling.IMPLICATIONS FOR PRACTICE: This study describes issues that contribute to both negative and positive experiences. Improved professional awareness and knowledge about these issues can contribute to the development of patient information and professional encounters, and may improve patients' compliance and overall experience.
  •  
4.
  • Pettersson, Erik, 1987, et al. (författare)
  • Structure delineation in the presence of metal - A comparative phantom study using single and dual-energy computed tomography with and without metal artefact reduction
  • 2019
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier BV. - 2405-6316. ; 9, s. 43-49
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Metal artefacts in computed tomography (CT) images impairs structure delineation. These artefacts can potentially be reduced with dual-energy CT (DECT) with or without using metal artefact reduction (MAR). The purpose was to investigate how structure delineation in DECT with or without MAR and single-energy CT (SECT) images were affected by metals. Materials and methods: A phantom with known irregular structures was developed. References tructures were determined from a low-noise scan without metal. Bilateral hip prostheses were simulated with steel or titanium inserts. The phantom was scanned with SECT and fast-kV switching DECT with optional MAR. Four radiation oncologists delineated the structures in two phantom set-ups. Delineated structures were evaluated with Dice similarity coefficient (DSC) and Hausdorff distance relative to the reference structures. Results: With titanium inserts, more structures were detected for non-MAR DECT compared to SECT while the same or less were detected with steel inserts. MAR improved delineation in DECT images. For steel inserts, Three structures in the region of artefacts, were delineated by at least two oncologists with MAR-DECT compared to none with non-MAR DECT or SECT. The highest values of DSC for MAR-DECT were 0.69, 0.81 and 0.77 for those structures. Conclusions: Delineation was improved with non-MAR DECT compared to SECT, especially for titanium inserts. A larger improvement was seen with the use of MAR for both steel and titanium inserts. The improvement was dependent on the location of the structure relative to the inserts, and the structure contrast relative to the background.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy