SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Böhnel M) "

Sökning: WFRF:(Böhnel M)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Wong, Winnie S., et al. (författare)
  • A pixel detector asic for dosimetry using time-over-threshold energy measurements
  • 2011
  • Ingår i: Radiation Measurements. - : Elsevier BV. - 1350-4487 .- 1879-0925. ; 46:12, s. 1619-1623
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work we present the design of a chip which provides the readout of a highly segmented diode array, in which signals induced by individual X-ray photons are processed discretely. There are several benefits to this approach, including the ability to achieve a high signal to noise ratio due to the inherently low sensor capacitance, and the suppression of background noise (e.g. dark current) using an analogue threshold. The segmentation also ensures a linear behaviour even at very high dose rates. A time over threshold (ToT1) energy measurement technique provides an immediate digital value corresponding to the energy deposited onto the diode by each individual photon. Deadtime-free operation is achieved by reading out a subset of the detector segments at a time while the rest of the detector continues to process signals. This paper describes the application-specific integrated circuit (ASIC) chip which was designed to provide pre-processing of photo-induced signals in the detector and readout of the processed digital data.
  •  
2.
  • Wong, Winnie S, et al. (författare)
  • Electrical measurements of a multi-mode hybrid pixel detector ASIC for radiation detection
  • 2012
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 7:1, s. Art. no. C01056-
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the first electrical measurements of an application-specific integrated circuit (ASIC) to be used in a hybrid pixel detector intended for dosimetry and radiation detection. The dosimeter has three programmable modes of operation: photon counting mode, energy integration mode, and dosimetry mode. The ASIC comprises a matrix of 16 by 16 (256 total) square pixels of 220 ÎŒm pitch, providing 12.4 mm 2 of segmented active area. Each pixel can be configured to operate in one of the three radiation measurement modes, with programmable-depth counters and shift registers to tailor the data word size and optimise the readout frame-rate in a given mode. The individual energies of impinging photons are determined through programmable analogue energy threshold discrimination, time over threshold measurement, or a combination thereof. Furthermore, the dosimetry mode contains 16 digital energy thresholds and automatically sorts data into 16 corresponding energy bin registers. The chip's output is therefore pre-processed charge spectra of the radiation field. This paper discusses results from measurements taken using programmable test-pulses to inject controlled stimuli into the pixel circuits.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Campbell, M. (2)
Anton, G. (2)
Michel, T (2)
Ballabriga, R. (2)
Tlustos, L. (2)
Heijne, E. (2)
visa fler...
Valerio, P. (2)
Sievers, P. (2)
Wong, Winnie S. (2)
Böhnel, M. (2)
Blaj, G. (1)
Llopart, X. (1)
Plackett, R. (1)
Poikela, T. (1)
Münster, I. (1)
Takoukam, P. (1)
Gabor, T (1)
Llopart, S (1)
Ritter, I (1)
visa färre...
Lärosäte
Mittuniversitetet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Teknik (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy