SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(BRUNORI G) "

Sökning: WFRF:(BRUNORI G)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Guiomar, N., et al. (författare)
  • Typology and distribution of small farms in Europe : Towards a better picture
  • 2018
  • Ingår i: Land use policy. - : Elsevier BV. - 0264-8377 .- 1873-5754. ; 75, s. 784-798
  • Tidskriftsartikel (refereegranskat)abstract
    • The contribution of small farms to local food supply, food security and food sovereignty is widely acknowledged at a global level. In the particular case of Europe, they often are seen as an alternative to large and specialised farms. Assessing the real role of small farms has been limited by a lack of information, as small farms are frequently omitted from agricultural censuses and national statistics. It is also well acknowledged that small farms differ widely, and are distributed according to different spatial patterns across Europe, fulfilling different roles according to the agriculture and territorial characteristics of each region. This paper presents the result of a novel classification of small farms at NUTS-3 level in Europe, according to the relevance of small farms in the agricultural and territorial context of each region, and based on a typology of small farms considering different dimensions of farm size. The maps presented result from an extensive data collection and variables selected according to European wide expert judgement, analysed with advanced cluster procedures. The results provide a fine grained picture of the role of small farms at the regional level in Europe today, and are expected to support further data analysis and targeted policy intervention.
  •  
3.
  •  
4.
  • Quétel, C. R., et al. (författare)
  • Methylmercury in tuna: demonstrating measurement capabilities and evaluating comparability of results worldwide from the CCQM P-39 comparison
  • 2005
  • Ingår i: Journal of Analytical Atomic Spectrometry. - : Royal Society of Chemistry (RSC). - 0267-9477 .- 1364-5544. ; 20, s. 1058-66
  • Tidskriftsartikel (refereegranskat)abstract
    • Six metrology institutes (NMIs) representing at the Comité International des Poids et Mesures (CIPM) 4 Member States of the Metre Convention and 2 international organisations, and 8 expert laboratories selected outside CIPM have compared their capabilities to quantitatively measure methylmercury (MeHg) in a prepared tuna material containing approximately 4.3 mg kg–1 Hg. This comparison was the object of the CIPM–Comité Consultatif pour la Quantité de Matière (CCQM) Pilot Study 39, organised by the Institute for Reference Materials and Measurements (IRMM), from the European Commission—Joint Research Centre. Beside the test material itself, a bottle of the BCR-464 tuna Certified Reference Material (CRM) and an ampoule of IRMM-670, a 202Hg isotope enriched MeHg candidate isotopic CRM, were distributed to all participants, who were free to apply the measurement strategy of their choice. Four, including 1 NMI, relied on external calibration or the method of standard additions, whereas the other 10 implemented an isotope dilution mass spectrometry (IDMS) approach and chose to use the IRMM-670 for their measurements. Alkaline digestion at room temperature (with manual shaking) or high temperature (under sonication, oven or hot plate conditions) was employed by most participants, with hydrochloric acid leaching the second most popular choice. Alkylation (4 phenylations, 4 ethylations and 3 propylations) in the aqueous phase was preferred by a large majority over butylation by the Grignard reaction. All participants were requested to estimate the uncertainty associated with their results and 9 out of 14 stated relative combined uncertainties below 6%(k= 2). Despite this apparent consensus, the perception of which factor caused the largest contribution to this estimation differed among participants because of the differences in the analytical methodologies deployed but also because of wide differences of the concepts of uncertainty estimation. The mixture mode(MM) median, calculated also from the measurement uncertainties stated by the participants, was 1.967 ± 0.204 × 10–5 mol kg–1(95% confidence). Twelve of the results were re-grouped within a range of less than 0.3 × 10–5 mol kg–1(MM median = 1.967 ± 0.162 × 10–5 mol kg–1, 95% confidence): they nearly all (1 exception) overlapped with each other within k= 2 stated uncertainties. For the other 2 results the uncertainty seemed to have been particularly underestimated as they lay, respectively, at more than 20% above and less than –40% below the overall average. The relative standard deviation of the results of 9 laboratories out of the 10 that applied IDMS was about 2.6%. It can be assumed from the degree of equivalence shown by 12 out of 14 study participants that, at present, laboratories worldwide are potentially able to supply accurate results for MeHg in fish-type matrices (containing about 2 × 10–5 mol kg–1) within ±10% uncertainty. This encouraging outcome permitted scheduling of a follow-up CCQM-K43 key comparison for a lower MeHg content level in salmon tissues.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy