SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bachoo P.) "

Sökning: WFRF:(Bachoo P.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Verhoeven, E. L. G., et al. (författare)
  • Real-world Performance of the New C3 Gore Excluder Stent-Graft : 1-year Results from the European C3 Module of the Global Registry for Endovascular Aortic Treatment (GREAT)
  • 2014
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 48:2, s. 131-137
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) provides "real-world" outcomes for the new C3 Gore Excluder stent-graft, and evaluates the new deployment mechanism. This report presents the 1-year results from 400 patients enrolled in this registry. Methods: Between August 2010 and December 2012, 400 patients (86.8% male, mean age 73.9 +/- 7.8 years) from 13 European sites were enrolled in this registry. Patient demographics, treatment indication, case planning, operative details including repositioning and technical results, and clinical outcome were analyzed. Results: Technical success was achieved in 396/400 (99%) patients. Two patients needed intraoperative open conversion, one for iliac rupture, the second because the stent-graft was pulled down during a cross-over catheterization in an angulated anatomy. Two patients required an unplanned chimney renal stent to treat partial coverage of the left renal artery because of upward displacement of the stent-graft. Graft repositioning occurred in 192/399 (48.1%) patients, most frequently for level readjustment with regard to the renal arteries, and less commonly for contralateral gate reorientation. Final intended position of the stent-graft below the renal arteries was achieved in 96.2% of patients. Thirty-day mortality was two (0.5%) patients. Early reintervention (<= 30 days) was required in two (0.5%) patients. Mean follow-up duration was 15.9 +/- 8.8 months (range 0-37 months). Late reintervention (>30 days) was required in 26 (6.5%) patients. Estimated freedom from reintervention at 1 year was 95.2% (95% CI 92.3-97%), and at 2 years 91.5% (95% CI 86.8-94.5%). Estimated patient survival at 1 year was 96% (95% CI 93.3-97.6%) and at 2 years 90.6% (95% CI 85.6-93.9%). Conclusions: Early real-world experience shows that the new C3 delivery system offers advantages in terms of device repositioning resulting in high deployment accuracy. Longer follow-up is required to confirm that this high deployment accuracy results in improved long-term durability.
  •  
2.
  • Bachoo, P., et al. (författare)
  • Early outcome of endovascular aneurysm repair in challenging aortic neck morphology based on experience from the GREAT C3 registry
  • 2013
  • Ingår i: Journal of Cardiovascular Surgery. - 0021-9509 .- 1827-191X. ; 54:5, s. 573-580
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim. The aim of this paper was to evaluate early outcome of the GORE (R) EXCLUDER (R) AAA Endoprosthesis featuring C3 Delivery System in subjects with aortic neck anatomy outside IFU. Methods. Individual patient data prospectively collected over a 2 year period from the Global Registry for Endovascular Aortic Treatment (GREAT). For each subject a minimum data set was collected containing demographic, pre/intra- and postoperative variables. Main outcome measures were successful exclusion of the AAA and occurrence of any major endoleak at 1 month. In this study, outside IFU was defined as aortic neck length less than 15 mm and/or aortic neck angle greater than 60 degrees. Results. A total of 400 subjects, (86.6% male, mean age 73.9 years). Primary pathology was AAA in 94.2% with 98.2% undergoing EVAR as a primary procedure. Sixty-eight subjects underwent EVAR outside IFU (neck length <15 nun N.=32, neck angle >60 degrees N.=47 and neck length <15 nun and angle >60 degrees N.=11). The graft was successfully deployed within 5 nun of its intended location in 63 (94%) cases utilising a total of 33 repositioning episodes. Eight aortic cuffs were used, 5 to treat a type 1 endoleak. At 30 days we recorded 2 type 2 endoleaks both successfully treated and 1 type 1b also successfully treated. There were 2 deaths, one in each group. Conclusion. GORE (R) EXCLUDER (R) AAA Endoprosthesis featuring C3 Delivery System allows re-positioning to be performed safely in cases outside IFU. Repositioning is an effective operative manoeuvre and facilitates EVAR in challenging anatomy. Longer follow-up is required to evaluate the durability of these results at 30 days.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Bachoo, P. (2)
Verhoeven, E. L. G. (2)
Larzon, Thomas (2)
Verhagen, H (1)
Boeckler, D. (1)
Fisher, R (1)
visa fler...
Brunkwall, J (1)
Kasprzak, P. (1)
Riambau, V. (1)
Ettles, D (1)
Katsargyris, A (1)
Stella, A (1)
Boyle, J. R. (1)
Florek, H-J (1)
visa färre...
Lärosäte
Örebro universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy