SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Baglioni C) "

Sökning: WFRF:(Baglioni C)

  • Resultat 1-10 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Mangialasche, Francesca, et al. (författare)
  • Classification and prediction of clinical diagnosis of Alzheimer's disease based on MRI and plasma measures of α-/γ-tocotrienols and γ-tocopherol.
  • 2013
  • Ingår i: Journal of Internal Medicine. - : Wiley. - 0954-6820 .- 1365-2796. ; 273:6, s. 602-621
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The aim of this study was to evaluate the accuracy of combined structural magnetic resonance imaging (MRI) measures and plasma levels of vitamin E forms, including all eight natural vitamin E congeners (four tocopherols and four tocotrienols) and markers of vitamin E oxidative/nitrosative damage, in differentiating individuals with Alzheimer's disease (AD) and mild cognitive impairment (MCI) from cognitively intact control (CTL) subjects.Methods: Overall, 81 patients with AD, 86 with MCI and 86 CTL individuals were enrolled from the longitudinal multicentre AddNeuroMed study. MRI and plasma vitamin E data were acquired at baseline. MRI scans were analysed using Freesurfer, an automated segmentation scheme which generates regional volume and cortical thickness measures. Orthogonal partial least squares to latent structures (OPLS), a multivariate data analysis technique, was used to analyse MRI and vitamin E measures in relation to AD and MCI diagnosis.Results: The joint evaluation of MRI and plasma vitamin E measures enhanced the accuracy of differentiating individuals with AD and MCI from CTL subjects: 98.2% (sensitivity 98.8%, specificity 97.7%) for AD versus CTL, and 90.7% (sensitivity 91.8%, specificity 89.5%) for MCI versus CTL. This combination of measures also identified 85% of individuals with MCI who converted to clinical AD at follow-up after 1 year.Conclusions: Plasma levels of tocopherols and tocotrienols together with automated MRI measures can help to differentiate AD and MCI patients from CTL subjects, and to prospectively predict MCI conversion into AD. Our results suggest the potential role of nutritional biomarkers detected in plasma–tocopherols and tocotrienols–as indirect indicators of AD pathology, and the utility of a multimodality approach.
  •  
10.
  • Nappini, S., et al. (författare)
  • Controlled drug release under a low frequency magnetic field: effect of the citrate coating on magnetoliposomes stability
  • 2011
  • Ingår i: Soft Matter. - : Royal Society of Chemistry (RSC). - 1744-6848 .- 1744-683X. ; 7:3, s. 1025-1037
  • Tidskriftsartikel (refereegranskat)abstract
    • The paper describes the effect of a low-frequency alternating magnetic field (LF-AMF) on the permeability and release properties of large (LUVs) and giant (GUVs) unilamellar vesicles loaded with citrate coated cobalt ferrite nanoparticles (NPs). The citrate shell allows a high loading of NPs in lipid vesicles without modifying their magnetic properties. The increase of magnetic LUVs permeability upon exposure to LF-AMF has been evaluated as the fluorescence self-quenching of carboxyfluorescein (CF) entrapped inside the liposome aqueous pool. Liposome leakage has been monitored as a function of field frequency, time exposure and concentration of the citrate coated NPs. Confocal Laser Scanning Microscopy (CLSM) experiments performed on magnetic GUVs labeled with the fluorescent probe DiIC18 and loaded with Alexa 488-C5-maleimide fluorescent dye provided insights on the release mechanism induced by LF-AMF. The results show that LF-AMF strongly affects vesicles permeability, suggesting the formation of pores in the lipid bilayer due to both hyperthermic effects and nanoparticle oscillations in the vesicles pool at the applied frequency. The behaviour of these magnetic vesicles in the presence of LF-AMF makes this system a good candidate for controlled drug delivery.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy