SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Baharudin Zikri A) "

Sökning: WFRF:(Baharudin Zikri A)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ahmad, Noor Azlinda, et al. (författare)
  • Characteristics of narrow bipolar pulses observed in Malaysia
  • 2010
  • Ingår i: Journal of Atmospheric and Solar-Terrestrial Physics. - : Elsevier BV. - 1364-6826 .- 1879-1824. ; 72:5-6, s. 534-540
  • Tidskriftsartikel (refereegranskat)abstract
    • Narrow bipolar pulses (NBPs) are considered as isolated intracloud events with higher peak amplitude and strong high frequency emission compared to the first return strokes and other intracloud discharges. From 182 NBPs recorded in Malaysia in the tropic, 75 were narrow negative bipolar pulses (NNBPs) while 107 were narrow positive bipolar pulses (NPBPs). The mean duration of NNBPs was 24.6 +/- 17.1 mu s, while 30.2 +/- 12.3 mu s was observed for NPBPs. The mean full-width at half-maximum (FVVHM) was 2.2 +/- 0.7 and 2.4 +/- 1.4 mu s for NNBPs and NPBPs, respectively. The mean peak amplitude of NPBPs normalized to 100 km was 22.7 V/m, a factor of 1.3 higher than that of NNBPs which is 17.6 V/m. In contrast to the previous studies, it was observed that the electric field change was characterized by a bipolar pulse with a significant amount of fine structures separated by a few tens of nanoseconds intervals, embedded on it. (C) 2010 Elsevier Ltd. All rights reserved.
  •  
2.
  • Ahmad, Noor Azlinda, et al. (författare)
  • Radiation field spectra of long-duration cloud flashes
  • 2015
  • Ingår i: Atmospheric Science Letters. - : Wiley. - 1530-261X. ; 16:2, s. 91-95
  • Tidskriftsartikel (refereegranskat)abstract
    • The preliminary results of radiation electric fields produced by long-duration cloud flashes have been Fourier analyzed to determine the frequency spectrum in the range of 10kHz-10MHz. The flashes were recorded within a distance of less than 20km. The spectrum was normalized to 50km distance and it shows a f(-1) dependence within the entire frequency range.
  •  
3.
  • Baharudin, Zikri A., et al. (författare)
  • Comparative study on preliminary breakdown pulse trains observed in Johor, Malaysia and Florida, USA
  • 2012
  • Ingår i: Atmospheric research. - : Elsevier BV. - 0169-8095 .- 1873-2895. ; 117, s. 111-121
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, the preliminary breakdown (PB) pulse train preceding the negative first return stroke (RS) is recorded using a broad band antenna system. These analyses were carried out in Johor Bahru, Malaysia and Florida, United States. This is a novel initiative at examining and identifying the characteristics of the PB pulse trains in the negative cloud-to-ground flashes observed in Malaysia. The arithmetic mean of the total pulse train duration is 12.3 ms and the weighted arithmetic mean of the pulse durations and interpulse intervals are 11 mu s and 152 mu s, respectively. The arithmetic mean ratio between the maximum peak amplitude of the PB pulse and the peak RS electric field was 27.8%, and the corresponding value in Florida was 29.4%. The arithmetic mean of the time duration between the most active part of the pulse train, and the RS was 57.6 ms in Malaysia and 22 ms in Florida. A qualitative comparison of our results with those obtained earlier in Sri Lanka. Sweden and Finland supports the hypothesis that the PBP/RS ratio is higher in the northern regions compared to the tropical regions. (C) 2012 Elsevier B.V. All rights reserved.
  •  
4.
  • Baharudin, Zikri A., et al. (författare)
  • Electric field changes generated by the preliminary breakdown for the negative cloud-to-ground lightning flashes in Malaysia and Sweden
  • 2012
  • Ingår i: Journal of Atmospheric and Solar-Terrestrial Physics. - : Elsevier BV. - 1364-6826 .- 1879-1824. ; 84-85, s. 15-24
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the study of the electric field changes generated by the preliminary breakdown for negative cloud-to-ground lightning flashes in Malaysia and Sweden concerning the association of slow field changes associated in preliminary breakdown process. We examined the total of 1685 negative cloud-to-ground lightning flashes from the total of 39 thunderstorms by recording the slow electric field, fast electric field and narrowband radiation field at 3 and 30 MHz signals simultaneously. Our results show that there is a pre-starting time, i.e. the duration between the first preliminary breakdown pulse and slow field changes starting point, which is found to be after the first preliminary breakdown pulse. The pre-starting time has the arithmetic and geometric mean range from 1.4-6.47 and 1-3.36 ms, respectively. The mean values of pre-starting time in Malaysia are greater than the values observed in Sweden by more than a factor of 3. From the two data sets it shows that the slow field changes never start before the preliminary breakdown. Furthermore, the use of single-station electric fields measurement with high resolutions of 12 bits transient recorder with several nanosecond accuracy allow one to distinguish the slow field changes generated by preliminary breakdown, which preceded the negative first return stroke, between tens to hundreds of milliseconds of pre-return stroke duration.
  •  
5.
  • Baharudin, Zikri A., et al. (författare)
  • Negative cloud-to-ground lightning flashes in Malaysia
  • 2014
  • Ingår i: Journal of Atmospheric and Solar-Terrestrial Physics. - : Elsevier BV. - 1364-6826 .- 1879-1824. ; 108, s. 61-67
  • Tidskriftsartikel (refereegranskat)abstract
    • The characteristics of the negative cloud-to-ground lightning flashes in Malaysia are studied by analyzing the electric fields generated by the whole flash in nanosecond resolution. A total of 405 strokes obtained from 100 successive negative cloud-to-ground lightning flashes were analyzed, which were recorded from seven convective thunderstorms during the southwest monsoon period, i.e. from April to June 2009. It was found that the total number of interstroke intervals has an arithmetic mean value of 86 ms, a geometric mean value of 67 ms and does not depend on the return stroke order. Of the 100 negative ground flashes, 38 flashes (38%) have at least one subsequent return-stroke (SRS) whose electric field peak was greater than that of the first return-stroke (RS). Furthermore, 58 (19%) out of 305 SRS have electric field peak larger than those of the first RS. The arithmetic and geometric mean ratio between the peak electric field of the SRS and the peak electric field of the first RS are 0.7 and 0.6, respectively. The percentage of single-stroke flashes was 16% while the mean number of strokes per flash and maximum number of stroke per flash were 4 and 14, respectively.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy