SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Baxter Douglas C.) "

Sökning: WFRF:(Baxter Douglas C.)

  • Resultat 1-10 av 33
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kanai, M, et al. (författare)
  • 2023
  • swepub:Mat__t
  •  
2.
  • Niemi, MEK, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Tiegs, Scott D., et al. (författare)
  • Global patterns and drivers of ecosystem functioning in rivers and riparian zones
  • 2019
  • Ingår i: Science Advances. - Washington : American Association of Advancement in Science. - 2375-2548. ; 5:1
  • Tidskriftsartikel (refereegranskat)abstract
    • River ecosystems receive and process vast quantities of terrestrial organic carbon, the fate of which depends strongly on microbial activity. Variation in and controls of processing rates, however, are poorly characterized at the global scale. In response, we used a peer-sourced research network and a highly standardized carbon processing assay to conduct a global-scale field experiment in greater than 1000 river and riparian sites. We found that Earth's biomes have distinct carbon processing signatures. Slow processing is evident across latitudes, whereas rapid rates are restricted to lower latitudes. Both the mean rate and variability decline with latitude, suggesting temperature constraints toward the poles and greater roles for other environmental drivers (e.g., nutrient loading) toward the equator. These results and data set the stage for unprecedented "next-generation biomonitoring" by establishing baselines to help quantify environmental impacts to the functioning of ecosystems at a global scale.
  •  
8.
  • Costello, David M., et al. (författare)
  • Global patterns and controls of nutrient immobilization on decomposing cellulose in riverine ecosystems
  • 2022
  • Ingår i: Global Biogeochemical Cycles. - : John Wiley & Sons. - 0886-6236 .- 1944-9224. ; 36:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Microbes play a critical role in plant litter decomposition and influence the fate of carbon in rivers and riparian zones. When decomposing low-nutrient plant litter, microbes acquire nitrogen (N) and phosphorus (P) from the environment (i.e., nutrient immobilization), and this process is potentially sensitive to nutrient loading and changing climate. Nonetheless, environmental controls on immobilization are poorly understood because rates are also influenced by plant litter chemistry, which is coupled to the same environmental factors. Here we used a standardized, low-nutrient organic matter substrate (cotton strips) to quantify nutrient immobilization at 100 paired stream and riparian sites representing 11 biomes worldwide. Immobilization rates varied by three orders of magnitude, were greater in rivers than riparian zones, and were strongly correlated to decomposition rates. In rivers, P immobilization rates were controlled by surface water phosphate concentrations, but N immobilization rates were not related to inorganic N. The N:P of immobilized nutrients was tightly constrained to a molar ratio of 10:1 despite wide variation in surface water N:P. Immobilization rates were temperature-dependent in riparian zones but not related to temperature in rivers. However, in rivers nutrient supply ultimately controlled whether microbes could achieve the maximum expected decomposition rate at a given temperature. Collectively, we demonstrated that exogenous nutrient supply and immobilization are critical control points for decomposition of organic matter.
  •  
9.
  • Appelblad, Petra K., et al. (författare)
  • The use of Pt guard electrode in inductively coupled plasma sectorÆeld mass spectrometry: advantages and limitations
  • 2000
  • Ingår i: Journal of Analytical Atomic Spectrometry. - : Royal Society of Chemistry (RSC). - 0267-9477 .- 1364-5544. ; 15:4, s. 359-364
  • Tidskriftsartikel (refereegranskat)abstract
    • Performance characteristics of inductively coupled plasma sector field mass spectrometry (ICP-SFMS) were studied with a Pt guard electrode (GE) inserted between the torch and load coil. The importance of the optimisation procedure and the matrix effects caused by a seawater matrix were assessed for 20 elements. Oxide and doubly charged ion formation was also investigated. Use of the GE allows a significant increase in ion transmission, by a factor of three to 20, thus resulting in improved instrumental detection limits. The improvement in sensitivity is mass dependent, with the highest gain observed for lower mass elements. Since, for the majority of analytical applications, actual detection limits depend upon blank levels rather on instrumental sensitivity, the most important factor for the determination of elements at ultra-trace levels is the degree of contamination of reagents and containers used. At the same time, significantly greater oxide formation is observed when operating the GE grounded rather than in the floating mode. For example, the BaO+/Ba+ ratio is ten to twelve times higher in the grounded mode. This calls for compromised instrumental parameters and the potential for severe spectral interferences from oxide species, which are often unresolved, even in high-resolution mode. Furthermore, non-spectral interferences from the seawater matrix appear to be more pronounced with the grounded GE, yielding a recovery of Ni of 55% compared with 93% in the floating GE mode. Hence all possible advantages and limitations of the use of the GE should be carefully considered prior to the analysis of real samples.
  •  
10.
  • Axelsson, Mikael D., et al. (författare)
  • High spatial resolution analysis of ferromanganese concretions by LA-ICP-MS
  • 2002
  • Ingår i: Geochemical Transactions. - : Springer Science and Business Media LLC. - 1467-4866. ; 3:5, s. 40-47
  • Tidskriftsartikel (refereegranskat)abstract
    • A procedure was developed for the determination of element distributions in cross-sections of ferromanganese concretions using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The effects of carrier flow rates, rf forward power, ablation energy, ablation spot size, repetition rate and number of shots per point on analyte intensity were studied. It is shown that different carrier gas flow rates are required in order to obtain maximum sensitivities for different groups of elements, thus complicating the optimisation of ICP parameters. On the contrary, LA parameters have very similar effects on almost all elements studied, thus providing a common optimum parameter set for the entire mass range. However, for selected LA parameters, the use of compromise conditions was necessary in order to compensate for relatively slow data acquisition by ICP-MS and maintain high spatial resolution without sacrificing the multielemental capabilities of the technique. Possible variations in ablation efficiency were corrected for mathematically using the sum of Fe and Mn intensities. Quantification by external calibration against matrix-matched standards was successfully used for more than 50 elements. These standards, in the form of pressed pellets (no binder), were prepared in-house using
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 33

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy