SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bayford Richard H.) "

Sökning: WFRF:(Bayford Richard H.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Becher, Tobias H., et al. (författare)
  • Prolonged Continuous Monitoring of Regional Lung Function in Infants with Respiratory Failure
  • 2022
  • Ingår i: Annals of the American Thoracic Society. - : American Thoracic Society. - 2329-6933 .- 2325-6621. ; 19:6, s. 991-999
  • Tidskriftsartikel (refereegranskat)abstract
    • Rationale: Electrical impedance tomography (EIT) allows instantaneous and continuous visualization of regional ventilation and changes in end-expiratory lung volume at the bedside. There is particular interest in using EIT for monitoring in critically ill neonates and young children with respiratory failure. Previous studies have focused only on short-term monitoring in small populations. The feasibility and safety of prolonged monitoring with EIT in neonates and young children have not been demonstrated yet.Objectives: To evaluate the feasibility and safety of long-term EIT monitoring in a routine clinical setting and to describe changes in ventilation distribution and homogeneity over time and with positioning in a multicenter cohort of neonates and young children with respiratory failure.Methods: At four European University hospitals, we conducted an observational study (NCT02962505) on 200 patients with postmenstrual ages (PMA) between 25 weeks and 36 months, at risk for or suffering from respiratory failure. Continuous EIT data were obtained using a novel textile 32-electrode interface and recorded at 48 images/s for up to 72 hours. Clinicians were blinded to EIT images during the recording. EIT parameters and the effects of body position on ventilation distribution were analyzed offline. Results: The average duration of FAT measurements was 53 +/- 20 hours. Skin contact impedance was sufficient to allow image reconstruction for valid ventilation analysis during a median of 92% (interquartile range, 77-98%) of examination time. EIT examinations were well tolerated, with minor skin irritations (temporary redness or imprint) occurring in 10% of patients and no moderate or severe adverse events. Higher ventilation amplitude was found in the dorsal and right lung areas when compared with the ventral and left regions, respectively. Prone positioning resulted in an increase in the ventilation-related EIT signal in the dorsal hemithorax, indicating increased ventilation of the dorsal lung areas. Lateral positioning led to a redistribution of ventilation toward the dependent lung in preterm infants and to the nondependent lung in patients with PMA > 37 weeks.Conclusions: EIT allows continuous long-term monitoring of regional lung function in neonates and young children for up to 72 hours with minimal adverse effects. Our study confirmed the presence of posture-dependent changes in ventilation distribution and their dependency on PMA in a large patient cohort.
  •  
2.
  • Seifnaraghi, Nima, et al. (författare)
  • Model Selection Based Algorithm in Neonatal Chest EIT
  • 2021
  • Ingår i: IEEE Transactions on Biomedical Engineering. - : IEEE. - 0018-9294 .- 1558-2531. ; 68:9, s. 2752-2763
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a new method for selecting a patient specific forward model to compensate for anatomical variations in electrical impedance tomography (EIT) monitoring of neonates. The method uses a combination of shape sensors and absolute reconstruction. It takes advantage of a probabilistic approach which automatically selects the best estimated forward model fit from pre-stored library models. Absolute/static image reconstruction is performed as the core of the posterior probability calculations. The validity and reliability of the algorithm in detecting a suitable model in the presence of measurement noise is studied with simulated and measured data from 11 patients. The paper also demonstrates the potential improvements on the clinical parameters extracted from EIT images by considering a unique case study with a neonate patient undergoing computed tomography imaging as clinical indication prior to EIT monitoring. Two well-known image reconstruction techniques, namely GREIT and tSVD, are implemented to create the final tidal images. The impacts of appropriate model selection on the clinical extracted parameters such as center of ventilation and silent spaces are investigated. The results show significant improvements to the final reconstructed images and more importantly to the clinical EIT parameters extracted from the images that are crucial for decision-making and further interventions.
  •  
3.
  • Bayford, Richard H., et al. (författare)
  • Locating Functionalized Gold Nanoparticles Using Electrical Impedance Tomography
  • 2022
  • Ingår i: IEEE Transactions on Biomedical Engineering. - : IEEE. - 0018-9294 .- 1558-2531. ; 69:1, s. 494-502
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: An imaging device to locate functionalised nanoparticles, whereby therapeutic agents are transported from the site of administration specifically to diseased tissues, remains a challenge for pharmaceutical research. Here, we show a new method based on electrical impedance tomography (EIT) to provide images of the location of gold nanoparticles (GNPs) and the excitation of GNPs with radio frequencies (RF) to change impedance permitting an estimation of their location in cell models Methods: We have created an imaging system using quantum cluster GNPs as contrast agent, activated with RF fields to heat the functionalized GNPs, which causes a change in impedance in the surrounding region. This change is then identified with EIT. Results: Images of impedance changes of around 80 ± 4% are obtained for a sample of citrate stabilized GNPs in a solution of phosphate-buffered saline. A second quantification was carried out using colorectal cancer cells incubated with culture media, and the internalization of GNPs into the colorectal cancer cells was undertaken to compare them with the EIT images. When the cells were incubated with functionalised GNPs, the change was more apparent, approximately 40 ± 2%. This change was reflected in the EIT image as the cell area was more clearly identifiable from the rest of the area. Significance: EIT can be used as a new method to locate functionalized GNPs in human cells and help in the development of GNP-based drugs in humans to improve their efficacy in the future.
  •  
4.
  • Bayford, Richard H., et al. (författare)
  • Locating Functionalized Gold Nanoparticles Using Electrical Impedance Tomography
  • 2022
  • Ingår i: IEEE Transactions on Biomedical Engineering. - : IEEE. - 0018-9294 .- 1558-2531. ; 69:1, s. 494-502
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: An imaging device to locate functionalised nanoparticles, whereby therapeutic agents are transported from the site of administration specifically to diseased tissues, remains a challenge for pharmaceutical research. Here, we show a new method based on electrical impedance tomography (EIT) to provide images of the location of gold nanoparticles (GNPs) and the excitation of GNPs with radio frequencies (RF) to change impedance permitting an estimation of their location in cell models Methods: We have created an imaging system using quantum cluster GNPs as contrast agent, activated with RF fields to heat the functionalized GNPs, which causes a change in impedance in the surrounding region. This change is then identified with EIT. Results: Images of impedance changes of around 80 +/- 4% are obtained for a sample of citrate stabilized GNPs in a solution of phosphate-buffered saline. A second quantification was carried out using colorectal cancer cells incubated with culture media, and the internalization of GNPs into the colorectal cancer cells was undertaken to compare them with the EIT images. When the cells were incubated with functionalised GNPs, the change was more apparent, approximately 40 +/- 2%. This change was reflected in the EIT image as the cell area was more clearly identifiable from the rest of the area. Significance: EIT can be used as a new method to locate functionalized GNPs in human cells and help in the development of GNP-based drugs in humans to improve their efficacy in the future.
  •  
5.
  • Hashemzadeh, Parham, 1976, et al. (författare)
  • Tracking Conductivity Variations in The Absence of Accurate State Evolution Models in Electrical Impedance Tomography
  • 2010
  • Ingår i: Proceedings of the 4th International Conference on Bioinformatics and Biomedical Engineering.
  • Konferensbidrag (refereegranskat)abstract
    • We present results on both linear and non-linear approaches in tracking conductivity variations in electrical impedance tomography. Throughout this study, we use both synthetic and measured data. The true system dynamics is considered as unknown and modelled as a random walk. In the linear reconstructions, the time evolution model is augmented with a Gaussian smoothness prior and results are shown using two different models for the covariance matrix of the process noise. Furthermore, we compare the reconstructions of the one step Gauss-Newton method to the Kalman filter on measured data from an adult human subject. In the non-linear study, we compare the performance of the extended Kalman filter against the particle filter on a simple test case. It is observed that the particle filter shows superior performance in tracking nonlinear/non-Gaussian conductivity variations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy