SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bendazzoli Simone) "

Sökning: WFRF:(Bendazzoli Simone)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bendazzoli, Simone, et al. (författare)
  • Automatic rat brain segmentation from MRI using statistical shape models and random forest
  • 2019
  • Ingår i: MEDICAL IMAGING 2019. - : SPIE-INT SOC OPTICAL ENGINEERING. - 9781510625464 - 9781510625457
  • Konferensbidrag (refereegranskat)abstract
    • In MRI neuroimaging, the shimming procedure is used before image acquisition to correct for inhomogeneity of the static magnetic field within the brain. To correctly adjust the field, the brain's location and edges must first be identified from quickly-acquired low resolution data. This process is currently carried out manually by an operator, which can be time-consuming and not always accurate. In this work, we implement a quick and automatic technique for brain segmentation to be potentially used during the shimming. Our method is based on two main steps. First, a random forest classifier is used to get a preliminary segmentation from an input MRI image. Subsequently, a statistical shape model of the brain, which was previously generated from ground-truth segmentations, is fitted to the output of the classifier to obtain a model-based segmentation mask. In this way, a-priori knowledge on the brain's shape is included in the segmentation pipeline. The proposed methodology was tested on low resolution images of rat brains and further validated on rabbit brain images of higher resolution. Our results suggest that the present method is promising for the desired purpose in terms of time efficiency, segmentation accuracy and repeatability. Moreover, the use of shape modeling was shown to be particularly useful when handling low-resolution data, which could lead to erroneous classifications when using only machine learning-based methods.
  •  
2.
  •  
3.
  • Brusini, Irene, et al. (författare)
  • Fully automatic estimation of the waist of the nerve fiber layer at the optic nerve head angularly resolved
  • 2021
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE-Intl Soc Optical Eng. ; , s. 1D1-1D8
  • Konferensbidrag (refereegranskat)abstract
    • The present project aims at developing a fully automatic software for estimation of the waist of the nerve fiber layer in the Optic Nerve Head (ONH) angularly resolved in the frontal plane as a tool for morphometric monitoring of glaucoma. The waist of the nerve fiber layer is here defined as Pigment epithelium central limit –Inner limit of the retina – Minimal Distance, (PIMD). 3D representations of the ONH were collected with high resolution OCT in young not glaucomatous eyes and glaucomatous eyes. An improved tool for manual annotation was developed in Python. This tool was found user friendly and to provide sufficiently precise manual annotation. PIMD was automatically estimated with a software consisting of one AI model for detection of the inner limit of the retina and another AI model for localization of the Optic nerve head Pigment epithelium Central limit (OPCL). In the current project, the AI model for OPCL localization was retrained with new data manually annotated with the improved tool for manual annotation both in not glaucomatous eyes and in glaucomatous eyes. Finally, automatic annotations were compared to 3 annotations made by 3 independent annotators in an independent subset of both the not glaucomatous and the glaucomatous eyes. It was found that the fully automatic estimation of PIMD-angle overlapped the 3 manual annotators with small variation among the manual annotators. Considering interobserver variation, the improved tool for manual annotation provided less variation than our original annotation tool in not glaucomatous eyes suggesting that variation in glaucomatous eyes is due to variable pathological anatomy, difficult to annotate without error. The small relative variation in relation to the substantial overall loss of PIMD in the glaucomatous eyes compared to the not glaucomatous eyes suggests that our software for fully automatic estimation of PIMD-angle can now be implemented clinically for monitoring of glaucoma progression.
  •  
4.
  • Kisonaite, Konstancija, et al. (författare)
  • Automatic estimation of the cross-sectional area of the waist of the nerve fiber layer at the optic nerve head
  • 2023
  • Ingår i: Acta Ophthalmologica. - : John Wiley & Sons. - 1755-375X .- 1755-3768.
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeGlaucoma leads to pathological loss of axons in the retinal nerve fibre layer at the optic nerve head (ONH). This study aimed to develop a strategy for the estimation of the cross-sectional area of the axons in the ONH. Furthermore, improving the estimation of the thickness of the nerve fibre layer, as compared to a method previously published by us.MethodsIn the 3D-OCT image of the ONH, the central limit of the pigment epithelium and the inner limit of the retina, respectively, were identified with deep learning algorithms. The minimal distance was estimated at equidistant angles around the circumference of the ONH. The cross-sectional area was estimated by the computational algorithm. The computational algorithm was applied on 16 non-glaucomatous subjects.ResultsThe mean cross-sectional area of the waist of the nerve fibre layer in the ONH was 1.97 ± 0.19 mm2. The mean difference in minimal thickness of the waist of the nerve fibre layer between our previous and the current strategies was estimated as CIμ (0.95) 0 ± 1 μm (d.f. = 15).ConclusionsThe developed algorithm demonstrated an undulating cross-sectional area of the nerve fibre layer at the ONH. Compared to studies using radial scans, our algorithm resulted in slightly higher values for cross-sectional area, taking the undulations of the nerve fibre layer at the ONH into account. The new algorithm for estimation of the thickness of the waist of the nerve fibre layer in the ONH yielded estimates of the same order as our previous algorithm.
  •  
5.
  • Kisonaite, Konstancija, et al. (författare)
  • Estimation of the cross-sectional surface area of the waist of the nerve fiber layer at the optic nerve head
  • 2022
  • Ingår i: Progress in Biomedical Optics and Imaging. - : SPIE-Intl Soc Optical Eng.
  • Konferensbidrag (refereegranskat)abstract
    • Glaucoma is a global disease that leads to blindness due to pathological loss of retinal ganglion cell axons in the optic nerve head (ONH). The presented project aims at improving a computational algorithm for estimating the thickness and surface area of the waist of the nerve fiber layer in the ONH. Our currently developed deep learning AI algorithm meets the need for a morphometric parameter that detects glaucomatous change earlier than current clinical follow-up methods. In 3D OCT image volumes, two different AI algorithms identify the Optic nerve head Pigment epithelium Central Limit (OPCL) and the Inner limit of the Retina Closest Point (IRCP) in a 3D grid. Our computational algorithm includes the undulating surface area of the waist of the ONH, as well as waist thickness. In 16 eyes of 16 non-glaucomatous subjects aged [20;30] years, the mean difference in minimal thickness of the waist of the nerve fiber layer between our previous and the current post-processing strategies was estimated as CIμ(0.95) 0 ±1 μm (D.f. 15). The mean surface area of the waist of the nerve fiber layer in the optic nerve head was 1.97 ± 0.19 mm2. Our computational algorithm results in slightly higher values for surface areas compared to published work, but as expected, this may be due to surface undulations of the waist being considered. Estimates of the thickness of the waist of the ONH yields estimates of the same order as our previous computational algorithm.
  •  
6.
  • Lidén, Mats, 1976-, et al. (författare)
  • Machine learning slice-wise whole-lung CT emphysema score correlates with airway obstruction
  • 2024
  • Ingår i: European Radiology. - : Springer. - 0938-7994 .- 1432-1084. ; 34:1, s. 39-49
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: Quantitative CT imaging is an important emphysema biomarker, especially in smoking cohorts, but does not always correlate to radiologists' visual CT assessments. The objectives were to develop and validate a neural network-based slice-wise whole-lung emphysema score (SWES) for chest CT, to validate SWES on unseen CT data, and to compare SWES with a conventional quantitative CT method.MATERIALS AND METHODS: Separate cohorts were used for algorithm development and validation. For validation, thin-slice CT stacks from 474 participants in the prospective cross-sectional Swedish CArdioPulmonary bioImage Study (SCAPIS) were included, 395 randomly selected and 79 from an emphysema cohort. Spirometry (FEV1/FVC) and radiologists' visual emphysema scores (sum-visual) obtained at inclusion in SCAPIS were used as reference tests. SWES was compared with a commercially available quantitative emphysema scoring method (LAV950) using Pearson's correlation coefficients and receiver operating characteristics (ROC) analysis.RESULTS: SWES correlated more strongly with the visual scores than LAV950 (r = 0.78 vs. r = 0.41, p < 0.001). The area under the ROC curve for the prediction of airway obstruction was larger for SWES than for LAV950 (0.76 vs. 0.61, p = 0.007). SWES correlated more strongly with FEV1/FVC than either LAV950 or sum-visual in the full cohort (r =  - 0.69 vs. r =  - 0.49/r =  - 0.64, p < 0.001/p = 0.007), in the emphysema cohort (r =  - 0.77 vs. r =  - 0.69/r =  - 0.65, p = 0.03/p = 0.002), and in the random sample (r =  - 0.39 vs. r =  - 0.26/r =  - 0.25, p = 0.001/p = 0.007).CONCLUSION: The slice-wise whole-lung emphysema score (SWES) correlates better than LAV950 with radiologists' visual emphysema scores and correlates better with airway obstruction than do LAV950 and radiologists' visual scores.CLINICAL RELEVANCE STATEMENT: The slice-wise whole-lung emphysema score provides quantitative emphysema information for CT imaging that avoids the disadvantages of threshold-based scores and is correlated more strongly with reference tests than LAV950 and reader visual scores.KEY POINTS: • A slice-wise whole-lung emphysema score (SWES) was developed to quantify emphysema in chest CT images. • SWES identified visual emphysema and spirometric airflow limitation significantly better than threshold-based score (LAV950). • SWES improved emphysema quantification in CT images, which is especially useful in large-scale research.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy