1.
  • Jemt, Torsten, 1950, et al. (författare)
  • Implant-supported welded titanium frameworks in the edentulous maxilla: a 5-year prospective multicenter study.
  • 2002
  • Ingår i: The International journal of prosthodontics. - 0893-2174. ; 15:6, s. 544-8
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: This study evaluated the 5-year clinical and radiographic performance of fixed implant-supported maxillary prostheses with either welded titanium or conventional cast-gold alloy frameworks. MATERIALS AND METHODS: Fifty-eight consecutive patients were provided with 349 osseointegrated Brånemark system implants in the edentulous maxilla at six different implant centers. Twenty-eight of the patients received, at random, prostheses with laser-welded titanium frameworks, and the remaining 30 patients had prostheses with conventional cast-gold alloy frameworks. Clinical and radiographic data were collected for 5 years after prosthesis placement. RESULTS: The titanium and cast-gold framework groups exhibited similar cumulative survival and success rates (CSR). The 5-year implant CSR from time of placement was 91.4% and 94.0%, respectively, and from prosthesis delivery the rate was 94.9% and 95.6%, respectively. The corresponding 5-year prosthesis CSRs were 96.4% and 93.3%. One patient from each group lost all the implants and turned to complete dentures within the first year of function. Another patient with a cast-gold framework had the prosthesis replaced after 4 years, basically because of problems with the veneering material. No fractures of implant components were observed during the follow-up period. Bone loss was on average 0.59 mm (SD 0.97 mm) during 5 years, with no statistical difference between the two groups. CONCLUSION: Welded titanium frameworks presented a similar favorable clinical performance as conventional cast-gold alloy frameworks in fixed implant-supported prostheses in the edentulous maxilla after 5 years in function. Implant failures were concentrated in only a few patients in each study group.
  •  
2.
  • Jemt, Torsten, 1950, et al. (författare)
  • Laser-welded titanium frameworks supported by implants in the edentulous maxilla: a 2-year prospective multicenter study.
  • 1998
  • Ingår i: The International journal of prosthodontics. - 0893-2174. ; 11:6, s. 551-7
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The aim of this study was to evaluate the clinical and radiographic performance of patients who received implants and fixed prostheses with laser-welded titanium frameworks. MATERIALS AND METHODS: Fifty-eight consecutive patients were treated with 349 osseointegrated implants ad modum Brånemark in the edentulous maxilla at 6 implant centers. The patients were randomly arranged into 2 groups at the time of final impression. Twenty-eight patients received laser-welded titanium frameworks and 30 patients received conventional cast frameworks. Clinical and radiographic data were collected for 2 years in function. RESULTS: The 2 groups of patients showed similar results. The 2-year overall cumulative implant survival rate from the time of implant placement and prosthesis insertion was 93.7% and 96.2%, respectively. The corresponding cumulative survival rate for prostheses was 96.6%. Two patients, 1 from each group, failed completely and resumed using conventional complete dentures. The only obvious factor that could possibly be related to the 2 complete failures was a smoking habit. However, it was not possible to significantly correlate implant failures to smoking habits in this study. No fractures were observed in the frameworks or implant components, and both groups experienced the same frequency of resin veneering material fractures. The overall average marginal bone loss was 0.4 mm (SD 0.8 mm). CONCLUSION: Patients treated with implant-supported prostheses fabricated with laser-welded titanium frameworks in the edentulous maxilla presented comparable results to patients with conventional cast frameworks after 2 years in function.
  •  