SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bergman Anders) "

Sökning: WFRF:(Bergman Anders)

  • Resultat 1-10 av 526
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Mohaupt, P., et al. (författare)
  • Extension and optimization of the load range of DRT test systems for testing extra long HV and UHV cables
  • 2012
  • Ingår i: 44th International Conference on Large High Voltage Electric Systems 2012.
  • Konferensbidrag (refereegranskat)abstract
    • In the last few years, the demand for testing extra-long cables, such as submarine cables has grown rapidly. The existing testing methods have been complemented by a new testing technology called DRT (Differential Resonance Technology). This testing method enables testing of extra-long cables by comparably small and light-weight equipment using a low frequency for the test voltage, e.g. 0.1Hz up to 5Hz. This leads to a significant decrease of the required power of the test source [1]. In a resonant circuit only the losses of the generator's individual components, specifically the high voltage reactor, have to be covered by the mains. The testing power itself remains fully compensated. Typical ratios between the testing power and the input power of resonant test systems start at 50 and go up to 100, depending on the load. Unfortunately, voltage generation based on inductive generation principles such as resonant circuits cannot economically be used for frequencies below 10Hz due to the massive iron cores needed for such a low frequency. The DRT method for the generation of low frequency high voltage is based on a high frequency voltage whose amplitude is modulated by the desired low frequency. Using a resonator, which is tuned to the high frequency, and a demodulator, the desired low frequency high voltage can be generated [1,2]. The input power required - and in direct relation to this the size and weight of the equipment - is significantly smaller than for other existing methods. In order to optimize the operation performance of the DRT system, this paper describes mathematical methods and algorithms, which have already been implemented and tested in a DRT test set. The basis for these algorithms is a mathematical description of the system based on an envelope model. Using this mathematical description of the nonlinear system behavior, a systematic analysis of the performance and the limits of the system can be given. The theoretical approach was experimentally proven by measuring the output voltage and the input power of a prototype unit ultimately designed to produce 200 kV rms. A first test was performed at SP Technical Research Institute of Sweden, using their reference measurement system for very low frequency (VLF) [3, 4] to measure the high VLF voltage. The reference measurement system provides a traceable uncertainty of down to 0.04 % over a voltage range up to 200 kV rms. The frequency range of the reference system is from 0.1 Hz up to 50 Hz. This system permits acquisition of complete waveforms that can be analysed for harmonic content and/or THD (Total Harmonic Distortion). Further tests are planned, where the connected load will be increased to the specified maximum 1 μF at 200 kV, and the characteristics will be explored both as regards to output voltage quality, input power requirements and distortion on the input current.
  •  
3.
  • Mohaupt, P., et al. (författare)
  • Extension and optimization of the load range of DRT test systems for testing extra-long HV and UHV cables
  • 2013
  • Ingår i: Elektrotechnik und Informationstechnik. - : Springer Science and Business Media LLC. - 0932-383X.
  • Tidskriftsartikel (refereegranskat)abstract
    • In the last few years, the demand for testing extra-long cables, such as submarine cables has grown rapidly. The existing testing methods have been complemented by a new testing technology called DRT (Differential Resonance Technology). This testing method enables testing of extra-long cables by comparably small and light-weight equipment using a low frequency for the test voltage, e.g. 0.1 Hz up to 5 Hz. This leads to a significant decrease of the required power of the test source (P. Mohaupt and A. Bergman in CIGRE 2010). In a resonant circuit only the losses of the generator's individual components, specifically the high voltage reactor, have to be covered by the mains. The testing power itself remains fully compensated. Typical ratios between the testing power and the input power of resonant test systems start at 50 and go up to 100, depending on the load. Unfortunately, voltage generation based on inductive generation principles such as resonant circuits cannot economically be used for frequencies below 10 Hz due to the massive iron cores needed for such a low frequency. The DRT method for the generation of low frequency high voltage is based on a high frequency voltage whose amplitude is modulated by the desired low frequency. Using a resonator, which is tuned to the high frequency, and a demodulator, the desired low frequency high voltage can be generated (P. Mohaupt and A. Bergman in CIGRE 2010; P. Mohaupt and T. Mehl in Jicable 2011). The input power required-and in direct relation to this the size and weight of the equipment-is significantly smaller than for other existing methods. In order to optimize the operation performance of the DRT system, this paper describes mathematical methods and algorithms, which have already been implemented and tested in a DRT test set. The basis for these algorithms is a mathematical description of the system based on an envelope model. Using this mathematical description of the nonlinear system behavior, a systematic analysis of the performance and the limits of the system can be given. The theoretical approach was experimentally proven by measuring the output voltage and the input power of a prototype unit ultimately designed to produce 200 kV rms. A first test was performed at SP Technical Research Institute of Sweden, using their reference measurement system for very low frequency (VLF) S. Bergman and A. Bergman (Proc. CPEM Conf. Dig., pp. 682-683, 2010; IEEE Trans. Instrum. Meas. 60:2422-2426, 2011) to measure the high VLF voltage. The reference measurement system provides a traceable uncertainty of down to 0.04 % over a voltage range up to 200 kV rms. The frequency range of the reference system is from 0.1 Hz up to 50 Hz. This system permits acquisition of complete wave-forms that can be analysed for harmonic content and/or THD (Total Harmonic Distortion). Further tests are planned, where the connected load will be increased to the specified maximum 1 μF at 200 kV, and the characteristics will be explored both as regards to output voltage quality, input power requirements and distortion on the input current. © 2013 CIGRE -- Reprint from www.cigre.org with kind permission.
  •  
4.
  • Ambrosi, Aurelie, et al. (författare)
  • Development of heart block in children of SSA/SSB-autoantibody-positive women is associated with maternal age and displays a season-of-birth pattern
  • 2012
  • Ingår i: Annals of the Rheumatic Diseases. - London : BMJ Publishing Group. - 0003-4967 .- 1468-2060. ; 71:3, s. 334-340
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective Congenital heart block may develop in the fetuses of Ro/SSA-positive and La/SSB-positive mothers. Recurrence rates of only 10-20% despite persisting maternal antibodies indicate that additional factors are critical for the establishment of heart block. The authors investigated the influence of other maternal and fetal factors on heart block development in a Swedish population-based cohort. less thanbrgreater than less thanbrgreater thanMethods The influence of fetal gender, maternal age, parity and time of birth on heart block development was analysed in 145 families, including Ro/La-positive (n=190) and Ro/La-negative (n=165) pregnancies. less thanbrgreater than less thanbrgreater thanResults There was a recurrence rate of 12.1% in Ro/La-positive women, and no recurrence in Ro/La-negative women. Fetal gender and parity did not influence the development of heart block in either group. Maternal age in Ro/La-positive pregnancies with a child affected by heart block was, however, significantly higher than in pregnancies resulting in babies without heart block (pandlt;0.05). Seasonal timing of pregnancy influenced the outcome. Gestational susceptibility weeks 18-24 occurring during January-March correlated with a higher proportion of children with heart block and lower vitamin D levels during the same period in a representative sample of Swedish women and a corresponding higher proportion of children with heart block born in the summer (pandlt;0.02). Maternal age or seasonal timing of pregnancy did not affect the outcome in Ro/La-negative pregnancies. less thanbrgreater than less thanbrgreater thanConclusion This study identifies maternal age and seasonal timing of pregnancy as novel risk factors for heart block development in children of Ro/La-positive women. These observations may be useful for counselling when pregnancy is considered.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Angelstam, Per, et al. (författare)
  • Evidence-Based Knowledge Versus Negotiated Indicators for Assessment of Ecological Sustainability : The Swedish Forest Stewardship Council Standard as a Case Study
  • 2013
  • Ingår i: Ambio. - : Springer Science and Business Media LLC. - 0044-7447 .- 1654-7209. ; 42:2, s. 229-240
  • Tidskriftsartikel (refereegranskat)abstract
    • Assessing ecological sustainability involves monitoring of indicators and comparison of their states with performance targets that are deemed sustainable. First, a normative model was developed centered on evidence-based knowledge about (a) forest composition, structure, and function at multiple scales, and (b) performance targets derived by quantifying the habitat amount in naturally dynamic forests, and as required for presence of populations of specialized focal species. Second, we compared the Forest Stewardship Council (FSC) certification standards' ecological indicators from 1998 and 2010 in Sweden to the normative model using a Specific, Measurable, Accurate, Realistic, and Timebound (SMART) indicator approach. Indicator variables and targets for riparian and aquatic ecosystems were clearly under-represented compared to terrestrial ones. FSC's ecological indicators expanded over time from composition and structure towards function, and from finer to coarser spatial scales. However, SMART indicators were few. Moreover, they poorly reflected quantitative evidence-based knowledge, a consequence of the fact that forest certification mirrors the outcome of a complex social negotiation process.
  •  
10.
  • Backudd, Ingrid, et al. (författare)
  • Genomförande av MCP-direktivet : Förslag till svenskt genomförande av direktiv 2015/2193/EU om begränsning av utsläpp till luften av vissa föroreningar från medelstora förbränningsanläggningar
  • 2017
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Naturvårdsverket förslag består av en ny förordning om medelstora förbränningsanläggningar (FMF) meddelad med stöd av 9 kap. 5 § miljöbalken i fråga om försiktighetsmått, 26 kap. 19 § miljöbalken i fråga om dokumentation och i övrigt med stöd av 8 kap. 7 § regeringsformen. Förslagets syfte är att se till att Sverige genomför alla bestämmelser som krävs enligt MCPD. Enligt direktivet ska medlemsstaterna se till att lagar och andra författningar som följer av MCPD träder i kraft senast den 19 december 2017.Direktivet medger ett flertal lättnader i form av dispenser, undantag samt möjligheter till senareläggande av tillämpningen av begränsningsvärden för specifika situationer. I förslaget har vi valt att genomföra vissa av de möjligheter till lättnader som finns i direktivet men inte samtliga. Förslaget innebär därför en skarpare implementering jämfört med en minimi-implementering, som utgör nollalternativet. Vi föreslår även skärpning av vissa begränsningsvärden. Som stödtill den formationsförsörjning som följer av direktivet föreslår vi en nationell digital lösning. I den konsekvensbeskrivning som har gjorts av förslaget framgår att de verksamheter som främst berörs av föreslagna skärpningar är fjärrvärmeanläggningar och anläggningar inom skogsindustrin. Förslaget som helhet är samhällsekonomiskt motiverat då skadekostnaden överstiger marginalkostnaden för år 2025. Skadekostnaden har beräknats enligt ASEKs metod och eftersom då utsläpp från fjärrvärmeanläggningar sker i tätortsmiljöer bedöms denna metod vara tillräckligt representativ för en jämförelse. Anläggningar inom skogsindustrin ligger dock inte i tätortsmiljö men enligt vår bedömning har de inte möjlighet att nyttja lättnaden för förbränning av fast biomassa eftersom de inte kan uppfylla direktivets begränsningsvärde för detta utan att installera avancerad reningsteknik. Motivet till de vägval som gjorts när förslaget tagits fram är att genomförandet av MCPD ska bli så ändamålsenligt som möjligt utifrån direktivet syfte och för svenska förhållanden. Vi har här bl.a. tagit hänsyn till miljönyttan med minskade utsläpp av stoft som bidrar till en bättre luftkvalitet och därmed minskade effekter på hälsa från dessa utsläpp. Ambitionen är att tillämpningen av författningen ska vara utformad på ett sådant sätt att administrativa kostnader för verksamhetsutövare och berörda myndigheter inte blir orimligt stora.Förslaget följer, där det är lämpligt, samma upplägg som förordningen (2013:252)om stora förbränningsanläggningar eftersom det finns stora likheter mellan bakomliggande direktiv.Lösning för informationshanteringen:I förslaget avseende informationshanteringen ingår en nationell lösning som stöd för verksamhetsutövarens underrättelse om sin anläggning, tillsynsmyndighetens registerhållning och spridning av registeruppgifter samt Naturvårdsverkets sammanställning av uppgifter för rapportering till EU.I förslaget ingår att Naturvårdsverket utvecklar och tillhandahåller en nationell etjänst. Verket utvecklar och tillhandahåller också en nationell databas i vilken de inhämtade uppgifterna lagras för tillsynsmyndigheternas räkning. Denna databas utgör den gemensamma tekniska lösningen för de register över medelstora förbränningsanläggningar som tillsynsmyndigheterna är skyldiga att föra.Naturvårdsverket utvecklar och tillhandahåller den tekniska lösningen för att skapa och publicera INSPIRE-tjänster för medelstora förbränningsanläggningar baserat på uppgifterna i databasen. För att underlätta offentliggörandet av registeruppgifterna ingår även att Naturvårdsverket utvecklar och tillhandahåller relevanta maskin/maskin-gränssnitt för respektive myndighets åtkomst till information i den nationella databasen.Tillämpning av begränsningsvärdenDirektivet medger vissa lättnade i form av undantag och möjligheter till senareläggande av tillämpningen av begränsningsvärden för specifika situationer. Vi har valt att föreslå en skarpare implementering jämfört med nollalternativet för vissa situationer dels vad gäller tidpunkten för tillämpningen av kraven samt skärpning av vissa begränsningsvärden.Skärpningar av större betydelse är följande:? Vi genomför inte möjligheten till en senareläggning av när tillämpningen träder i kraft för befintliga fjärrvärmeanläggningar med en installerad tillförd effekt av 5-50 megawatt (MW) (artikel 6.5 första stycket MCPD).? Vi genomför inte möjligheten till en senareläggning av när tillämpningen träder i kraft för nya anläggningar som använder fast biomassa som huvudsakligt bränsle (artikel 6.5 andra stycket MCPD).? Vi genomför inte möjligheten till en senareläggning av när tillämpningen träder i kraft för befintliga anläggningar med en installerad tillförd effekt av 5-50 MW som använder fast biomassa som huvudsakligt bränsle (artikel 6.5 andra stycket MCPD).? Vi genomför inte möjligheten till utökad tidsgräns för befintliga anläggningar med begränsad drifttid per år från 500 till 1 000, som rullande femårigt medelvärde vid extraordinära situationer (artikel 6.3 MCPD).? Begränsningsvärdet för utsläpp av NOx från befintlig medelstor förbränningsanläggning vid förbränning av fast biomassa och övriga fasta bränslen bör skärpas från 650 mg/Nm3 till 300 mg/Nm3. För anläggningar som förbränner flytande biobränsle sätts begränsningsvärdet till 450 mg/Nm3. Samtliga begränsningsvärden gäller vid 6 % O2.Kontroll av efterlevnadVi föreslår inga skärpningar här jämfört med nollalternativet. MCPD ställer dock krav på utsläppsövervakning samt att efterlevnaden av direktivet kontrolleras. Detta innebär konsekvenser för verksamhetsutövare i form av krav på att utsläpp mäts och beräknas samt dokumenteras. För tillsynsmyndigheterna innebär det ytterligare ett regelverk att kontrollera efterlevnaden av samt en skyldighet att hålla register och att tillgängliggöra information publikt.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 526
Typ av publikation
tidskriftsartikel (325)
konferensbidrag (84)
annan publikation (35)
rapport (25)
doktorsavhandling (24)
bokkapitel (14)
visa fler...
samlingsverk (redaktörskap) (5)
bok (4)
licentiatavhandling (4)
forskningsöversikt (3)
proceedings (redaktörskap) (2)
patent (1)
visa färre...
Typ av innehåll
refereegranskat (407)
övrigt vetenskapligt/konstnärligt (106)
populärvet., debatt m.m. (13)
Författare/redaktör
Bergman, Anders (172)
Eriksson, Olle (59)
Bergman, Anders, 197 ... (53)
Eriksson, Olle, 1960 ... (40)
Pereiro, Manuel (34)
Bignert, Anders (32)
visa fler...
Nordström, Lars (31)
Bergman, Åke (30)
Delin, Anna, 1966- (26)
Eriksson, Per (23)
Thonig, Danny, 1986- (22)
Chico, Jonathan (21)
Stenerlöw, Bo (20)
Sjöqvist, Erik (19)
Bergqvist, Lars (19)
Sundell-Bergman, Syn ... (18)
Fredriksson, Anders (17)
Salomaa, Veikko (15)
Wareham, Nicholas J. (15)
McCarthy, Mark I (15)
Boehnke, Michael (15)
Tuomilehto, Jaakko (15)
Buratovic, Sonja (15)
Delin, Anna (15)
Elg, Alf Peter (15)
Jackson, Anne U. (15)
Mohlke, Karen L (14)
Gieger, Christian (14)
Barroso, Ines (14)
Loos, Ruth J F (14)
Prokopenko, Inga (14)
Collins, Francis S. (14)
Lindgren, Cecilia M. (14)
Morris, Andrew P. (14)
Stringham, Heather M (14)
Groop, Leif (13)
Deloukas, Panos (13)
Kuusisto, Johanna (13)
Laakso, Markku (13)
Hamsten, Anders (13)
Luan, Jian'an (13)
Illig, Thomas (13)
Grallert, Harald (13)
Lind, Lars (12)
Qi, Lu (12)
Stefansson, Kari (12)
Metspalu, Andres (12)
Hellsvik, Johan (12)
Frayling, Timothy M (12)
Esko, Tõnu (12)
visa färre...
Lärosäte
Uppsala universitet (244)
Karolinska Institutet (78)
Kungliga Tekniska Högskolan (74)
RISE (66)
Umeå universitet (61)
Lunds universitet (55)
visa fler...
Stockholms universitet (42)
Örebro universitet (42)
Linköpings universitet (37)
Göteborgs universitet (34)
Chalmers tekniska högskola (29)
Luleå tekniska universitet (24)
Sveriges Lantbruksuniversitet (19)
Karlstads universitet (15)
Naturhistoriska riksmuseet (9)
Södertörns högskola (8)
Linnéuniversitetet (7)
Naturvårdsverket (6)
Mälardalens universitet (5)
Högskolan i Halmstad (4)
Jönköping University (3)
Malmö universitet (2)
Gymnastik- och idrottshögskolan (2)
Högskolan Dalarna (2)
Högskolan i Gävle (1)
Försvarshögskolan (1)
VTI - Statens väg- och transportforskningsinstitut (1)
Sophiahemmet Högskola (1)
visa färre...
Språk
Engelska (481)
Svenska (34)
Latin (5)
Odefinierat språk (3)
Danska (1)
Spanska (1)
visa fler...
Kinesiska (1)
visa färre...
Forskningsämne (UKÄ/SCB)
Naturvetenskap (239)
Medicin och hälsovetenskap (101)
Teknik (78)
Samhällsvetenskap (37)
Humaniora (16)
Lantbruksvetenskap (9)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy