SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bertuccio G.) "

Sökning: WFRF:(Bertuccio G.)

  • Resultat 1-10 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Feroci, M., et al. (författare)
  • The large observatory for x-ray timing
  • 2014
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 9780819496126
  • Konferensbidrag (refereegranskat)abstract
    • The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final downselection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supranuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m2 effective area, 2-30 keV, 240 eV spectral resolution, 1° collimated field of view) and a Wide Field Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g. GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the status of the mission at the end of its Phase A study.
  •  
2.
  • Amati, L., et al. (författare)
  • The THESEUS space mission concept : science case, design and expected performances
  • 2018
  • Ingår i: Advances in Space Research. - : ELSEVIER SCI LTD. - 0273-1177 .- 1879-1948. ; 62:1, s. 191-244
  • Tidskriftsartikel (refereegranskat)abstract
    • THESEUS is a space mission concept aimed at exploiting Gamma-Ray Bursts for investigating the early Universe and at providing a substantial advancement of multi-messenger and time-domain astrophysics. These goals will be achieved through a unique combination of instruments allowing GRB and X-ray transient detection over a broad field of view (more than 1 sr) with 0.5-1 arcmin localization, an energy band extending from several MeV down to 0.3 keV and high sensitivity to transient sources in the soft X-ray domain, as well as on-board prompt (few minutes) follow-up with a 0.7 m class IR telescope with both imaging and spectroscopic capabilities. THESEUS will be perfectly suited for addressing the main open issues in cosmology such as, e.g., star formation rate and metallicity evolution of the inter-stellar and intra-galactic medium up to redshift similar to 10, signatures of Pop III stars, sources and physics of re-ionization, and the faint end of the galaxy luminosity function. In addition, it will provide unprecedented capability to monitor the X-ray variable sky, thus detecting, localizing, and identifying the electromagnetic counterparts to sources of gravitational radiation, which may be routinely detected in the late '20s/early '30s by next generation facilities like aLIGO/ aVirgo, eLISA, KAGRA, and Einstein Telescope. THESEUS will also provide powerful synergies with the next generation of multi-wavelength observatories (e.g., LSST, ELT, SKA, CTA, ATHENA).
  •  
3.
  • Feroci, M., et al. (författare)
  • LOFT - The large observatory for x-ray timing
  • 2012
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE - International Society for Optical Engineering. - 9780819491442 ; , s. 84432D-
  • Konferensbidrag (refereegranskat)abstract
    • The LOFT mission concept is one of four candidates selected by ESA for the M3 launch opportunity as Medium Size missions of the Cosmic Vision programme. The launch window is currently planned for between 2022 and 2024. LOFT is designed to exploit the diagnostics of rapid X-ray flux and spectral variability that directly probe the motion of matter down to distances very close to black holes and neutron stars, as well as the physical state of ultradense matter. These primary science goals will be addressed by a payload composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a collimated (<1 degree field of view) experiment operating in the energy range 2-50 keV, with a 10 m2 peak effective area and an energy resolution of 260 eV at 6 keV. The WFM will operate in the same energy range as the LAD, enabling simultaneous monitoring of a few-steradian wide field of view, with an angular resolution of <5 arcmin. The LAD and WFM experiments will allow us to investigate variability from submillisecond QPO's to yearlong transient outbursts. In this paper we report the current status of the project.
  •  
4.
  • Feroci, M., et al. (författare)
  • The Large Observatory for X-ray Timing (LOFT)
  • 2012
  • Ingår i: Experimental Astronomy. - : Springer Science and Business Media LLC. - 0922-6435 .- 1572-9508. ; 34:2, s. 415-444
  • Tidskriftsartikel (refereegranskat)abstract
    • High-time-resolution X-ray observations of compact objects provide direct access to strong-field gravity, to the equation of state of ultradense matter and to black hole masses and spins. A 10 m(2)-class instrument in combination with good spectral resolution is required to exploit the relevant diagnostics and answer two of the fundamental questions of the European Space Agency (ESA) Cosmic Vision Theme "Matter under extreme conditions", namely: does matter orbiting close to the event horizon follow the predictions of general relativity? What is the equation of state of matter in neutron stars? The Large Observatory For X-ray Timing (LOFT), selected by ESA as one of the four Cosmic Vision M3 candidate missions to undergo an assessment phase, will revolutionise the study of collapsed objects in our galaxy and of the brightest supermassive black holes in active galactic nuclei. Thanks to an innovative design and the development of large-area monolithic silicon drift detectors, the Large Area Detector (LAD) on board LOFT will achieve an effective area of similar to 12 m(2) (more than an order of magnitude larger than any spaceborne predecessor) in the 2-30 keV range (up to 50 keV in expanded mode), yet still fits a conventional platform and small/medium-class launcher. With this large area and a spectral resolution of < 260 eV, LOFT will yield unprecedented information on strongly curved spacetimes and matter under extreme conditions of pressure and magnetic field strength.
  •  
5.
  • Ferreira, Mjv, et al. (författare)
  • Poster Session 3 : Tuesday 5 May 2015, 08
  • 2015
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 16 Suppl 1
  • Tidskriftsartikel (refereegranskat)
  •  
6.
  • Collatuzzo, G, et al. (författare)
  • Peptic ulcer as mediator of the association between risk of gastric cancer and socioeconomic status, tobacco smoking, alcohol drinking and salt intake
  • 2022
  • Ingår i: Journal of epidemiology and community health. - : BMJ. - 1470-2738 .- 0143-005X. ; 76:10, s. 861-866
  • Tidskriftsartikel (refereegranskat)abstract
    • Peptic ulcer disease (PUD) and gastric cancer (GC) are more prevalent in individuals with low socioeconomic status (SES) and share several risk factors. The aim of this study was to investigate the mediating role of PUD in the association between established risk factors and GC.MethodsWe conducted a pooled analysis of 12 studies from the Stomach Cancer Pooling Project Consortium, including a total of 4877 GC cases and 11 808 controls. We explored the mediating role of PUD in the association between SES, tobacco smoking, heavy alcohol drinking and salt intake, and GC. Also, we assessed the ORs and 95% CIs of the risk factors and both PUD and GC.ResultsPUD mediated 36% of the smoking effect mainly among men. Other risk factors were only slightly mediated by PUD (SES, 5.3%; heavy alcohol drinking, 3.3%; and salt intake, 2.5%). No significant difference was found when excluding PUD diagnosed within 2 years from GC.ConclusionsOur study provides innovative information on the mechanism of stomach mucosal damage leading to PUD and GC, with respect to the effect of tobacco smoking in particular.
  •  
7.
  • Bertuccio, Giuseppe, et al. (författare)
  • Ultra Low Noise Epitaxial 4H-SiC X-Ray Detectors
  • 2009
  • Ingår i: Materials Science Forum. - : Trans Tech Publications Inc.. - 0255-5476 .- 1662-9752. ; 615-617, s. 845-848
  • Tidskriftsartikel (refereegranskat)abstract
    • The design and the experimental results of some prototypes of SiC X-ray detectors are presented. The devices have been manufactured on top of 2 inch 4H-SiC wafer with 115 μm thick undoped high purity epitaxial layer, which constitutes the detection’s active volume. Pad and pixel detectors based on Ni-Schottky junctions have been tested. The residual doping of the epi-layer was found tobe extremely low, 3.7 x 1013 cm-3, allowing to achieve the highest detection efficiency and the lower specific capacitance of the detectors. At 22 °C and in operating bias condition, the reverse current densities of the detector’s Schottky junctions have been measured to be between J = 0.3 pA/cm2 and J = 4 pA/cm2; these values are more than two orders of magnitude lower than those of state of the art silicon detectors. With such low leakage currents, the equivalent electronic noise of SiC pixel detectors is as low as 0.5 electrons r.m.s at room temperature, which represents a new state of the art in the scenario of semiconductor radiation detectors.
  •  
8.
  • Experimental test of TOF diagnostics for PW class lasers
  • 2013
  • Proceedings (redaktörskap) (refereegranskat)abstract
    • New particle acceleration regimes driven by PW class lasers imply the development of new in-situ diagnostics. Before constructing new types of detectors one must test currently available diagnostics in these new regimes ofhigh intensity laser-matter interaction. Experimental tests on two types of time of flight detectors are presented, demonstrating the possibility of their measuring capabilities in harsh conditions, namely the strong laser induced electromagnetic pulse. A recently developed silicon carbide detector was successfully tested and particle beams were characterized. Further tests were performed on a detector based on secondary emission of electrons during the transition of laser accelerated particle beams. The presented results show a clear consistency and sufficient capabilities for high intensity laser driven particle beam detection.
  •  
9.
  • Picetti, Edoardo, et al. (författare)
  • Early management of isolated severe traumatic brain injury patients in a hospital without neurosurgical capabilities : a consensus and clinical recommendations of the World Society of Emergency Surgery (WSES)
  • 2023
  • Ingår i: World Journal of Emergency Surgery. - : BioMed Central (BMC). - 1749-7922. ; 18:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Severe traumatic brain-injured (TBI) patients should be primarily admitted to a hub trauma center (hospital with neurosurgical capabilities) to allow immediate delivery of appropriate care in a specialized environment. Sometimes, severe TBI patients are admitted to a spoke hospital (hospital without neurosurgical capabilities), and scarce data are available regarding the optimal management of severe isolated TBI patients who do not have immediate access to neurosurgical care.METHODS: A multidisciplinary consensus panel composed of 41 physicians selected for their established clinical and scientific expertise in the acute management of TBI patients with different specializations (anesthesia/intensive care, neurocritical care, acute care surgery, neurosurgery and neuroradiology) was established. The consensus was endorsed by the World Society of Emergency Surgery, and a modified Delphi approach was adopted.RESULTS: A total of 28 statements were proposed and discussed. Consensus was reached on 22 strong recommendations and 3 weak recommendations. In three cases, where consensus was not reached, no recommendation was provided.CONCLUSIONS: This consensus provides practical recommendations to support clinician's decision making in the management of isolated severe TBI patients in centers without neurosurgical capabilities and during transfer to a hub center.
  •  
10.
  • Rota, M, et al. (författare)
  • Erratum
  • 2018
  • Ingår i: International journal of cancer. - : Wiley. - 1097-0215 .- 0020-7136. ; 143:8, s. E10-E10
  • Tidskriftsartikel (refereegranskat)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy