SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bienz T) "

Sökning: WFRF:(Bienz T)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Klinge, Björn, et al. (författare)
  • Dental implant register: Summary and consensus statements of group 2. The 5th EAO Consensus Conference 2018
  • 2018
  • Ingår i: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 29:Supplement: 18, s. 157-159
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: This publication reports the EAO Workshop group-2 and consensus plenary discussions and statements on a narrative review providing the background and possible facilities and importance of a dental implant register, to allow for a systematic follow-up of the clinical outcome of dental implant treatment in various clinical settings. It should be observed that the format of the review and the subsequent consensus report consciously departs from conventional consensus publications and reports. Material and methods: The publication was a narrative review on the presence and significance of quality registers regarding select medical conditions and procedures. The group discussed and evaluated the publication and made corrections and recommendations to the authors and agreed on the statements and recommendations described in this consensus report. Results: Possible registrations to be included in an implant register were discussed and agreed as a preliminary basis for further development, meaning that additional parameters be included or some be deleted. Conclusions: It was agreed to bring the idea of an implant quality register, including the presented results of discussions and proposals by the group- and plenary sessions, to the EAO Board for further discussion and decision.
  •  
3.
  • Sanz, M., et al. (författare)
  • Biological aspects: Summary and consensus statements of group 2. The 5th EAO Consensus Conference 2018
  • 2018
  • Ingår i: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 29:Supplement: 18, s. 152-156
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: This publication reports the EAO Workshop group-2 discussions and consensus statements which provided the scientific evidence on the influence of biological parameters on implant-related clinical outcomes. Material and methods: The first publication was a systematic review on the biological effects of abutment material on the stability of peri-implant marginal bone levels and the second, a critical narrative review on how peri-implant diagnostic parameters correspond with long-term implant survival and success. The group evaluated the content of both publications, made corrections and recommendations to the authors and agreed on the consensus statements, clinical recommendations and recommendations for future research, which are described in this consensus report. Results: Tested abutment materials can be considered appropriate for clinical use according to the observation period studied (mean 3.5 years). Mean peri-implant bone loss and mean probing pocket depths are not adequate outcomes to study the prevalence of peri-implantitis, while the reporting of frequency distributions is considered more appropriate. Conclusions: Titanium is currently considered the standard of care as abutment material, although other materials may be more suitable for aesthetic locations. Peri-implantitis should be diagnosed through composite evaluations of peri-implant tissue inflammation and assessment of marginal bone loss with different thresholds.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy