SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Björk Wilhelms Daniel 1984 ) "

Sökning: WFRF:(Björk Wilhelms Daniel 1984 )

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Glasin, Joakim, et al. (författare)
  • Wireless vitals : Proof of concept for wireless patient monitoring in an emergency department setting
  • 2019
  • Ingår i: Journal of Biophotonics. - : Wiley-VCH Verlagsgesellschaft. - 1864-063X .- 1864-0648. ; 12:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Vital sign assessment is a common task in emergency medicine, but resources for continuous monitoring are restricted, data is often recorded manually, and entangled wires cause frustration. Therefore, we designed a small, wireless photoplethysmographic device capable of continuously assessing pulse, respiratory frequency and oxygen saturation on the sternum and tested the performance and feasibility in an emergency department setting. Fifty (56.3 20.2 years), consenting emergency patients (29 male) were recruited. Heart rate, respiratory rate and oxygen saturation were recorded simultaneously using the device and standard monitoring equipment. Data was compared using Bland-Altman plotting (heart rate, respiratory rate) and mean difference (oxygen saturation). The bias for heart- and respiratory rate was 0.4 (limits of agreements -11.3, 12.2 and -6.1, 7.0). Mean difference for oxygen saturation was -0.21 +/- 2.35%. This may be the first wireless device to use photoplethysmography on the sternum for vital sign assessment. We noted good agreement with standard monitors, but lack of standardization in data processing between monitoring systems may limit the generalizability of these findings. Although further improvements are needed, the feasibility of this approach provides proof of concept for a new paradigm of large scale, wireless patient monitoring.
  •  
2.
  • Henricson, Joakim, 1977-, et al. (författare)
  • In vivo dose-response analysis to acetylcholine : pharmacodynamic assessment by polarized reflectance spectroscopy
  • 2022
  • Ingår i: Scientific Reports. - London, United Kingdom : Nature Publishing Group. - 2045-2322. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Transdermal iontophoresis offers an in vivo alternative to the strain-gauge model for measurement of vascular function but is limited due to lack of technical solutions for outcome assessment. The aims of this study were to, after measurement by polarized reflectance spectroscopy (PRS), use pharmacodynamic dose-response analysis on responses to different concentrations of acetylcholine (ACh); and to examine the effect of three consecutively administered iontophoretic current pulses. The vascular responses in 15 healthy volunteers to iontophorised ACh (5 concentrations, range 0.0001% to 1%, three consecutive pulses of 0.02 mA for 10 min each) were recorded using PRS. Data were fitted to a four-parameter logistic dose response model and compared. Vascular responses were quantifiable by PRS. Similar pharmacodynamic dose response curves could be generated irrespectively of the ACh concentration. Linearly increasing maximum vasodilatory responses were registered with increasing concentration of ACh. A limited linear dose effect of the concentration of ACh was seen between pulses. Polarized reflectance spectroscopy is well suited for measuring vascular responses to iontophoretically administrated ACh. The results of this study support further development of iontophoresis as a method to study vascular function and pharmacological responses in vivo.
  •  
3.
  • Henricson, Joakim, 1977-, et al. (författare)
  • Respiratory rate monitoring in healthy volunteers by central photoplethysmography compared to capnography
  • 2022
  • Ingår i: Journal of Biophotonics. - : Wiley-V C H Verlag GMBH. - 1864-063X .- 1864-0648. ; 15:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Monitoring of respiration is a central task in clinical medicine, crucial to patient safety. Despite the uncontroversial role of altered respiratory frequency as an important sign of impending or manifest deterioration, reliable measurement methods are mostly lacking outside of intensive care units and operating theaters. Photoplethysmography targeting the central blood circulation in the sternum could offer accurate and inexpensive monitoring of respiration. Changes in blood flow related to the different parts of the respiratory cycle are used to identify the respiratory pattern. The aim of this observational study was to compare photoplethysmography at the sternum to standard capnography in healthy volunteers. Bland Altman analysis showed good agreement (bias -0.21, SD 1.6, 95% limits of agreement -3.4 to 2.9) in respiratory rate values. Photoplethysmography provided high-quality measurements of respiratory rate comparable to capnographic measurements. This suggests that photoplethysmography may become a precise, cost-effective alternative for respiratory monitoring.
  •  
4.
  • Hörlin, Erika, 1974-, et al. (författare)
  • Inter-rater reliability of the Clinical Frailty Scale by staff members in a Swedish emergency department setting
  • 2022
  • Ingår i: Academic Emergency Medicine. - : Wiley. - 1069-6563 .- 1553-2712. ; 29:12, s. 1431-1437
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction As frailty among the elderly is receiving increasing attention in emergency departments (EDs) around the world, the use of frailty assessment tools is growing. An often used such tool is the Clinical Frailty Scale (CFS), whose inter-rater reliability has been sparingly investigated in ED settings. No inter-rater reliability study regarding CFS has previously been performed within the Scandinavian ED context. The primary aim of this study was to evaluate the inter-rater reliability of the CFS in a Swedish ED setting. Methods This was a prospective observational study conducted at three Swedish EDs. Patients >= 65 years were independently assessed with CFS by their responsible physician, registered nurse, and assistant nurse. Demographic information for each assessor was collected, along with frailty status (frail/not frail) on the basis of clinical judgment. Inter-rater reliability was calculated using intraclass correlation coefficient (ICC), whereas agreement of frailty assessed by CFS (dichotomized between frail/not frail, cutoff at >= 5 points) versus solely by clinical judgment was calculated by using cross-tabulation. Results One-hundred patients were included. We found inter-rater reliability to be moderate to good (ICC 0.78, 95% confidence interval [CI] 0.72-0.84), regardless of whether the care team included an emergency physician (ICC 0.74, 95% CI 0.62-0.83) or an intern/resident from another specialty (ICC 0.83, 95% CI 0.74-0.89). The agreement of clinically judged frailty compared to frailty according to CFS was 84%. In the opposing cases, staff tended to assess patients as frail to a higher extent using clinical judgment than by applying CFS on the same patient. Conclusions The CFS appears to have a moderate to good inter-rater reliability when used in a clinical ED setting. When guiding clinical decisions, we advise that the CFS score should be discussed within the team. Further research needs to be performed on the accuracy of clinical judgment to identify frailty in ED patients.
  •  
5.
  • Toll John, Rani, 1975-, et al. (författare)
  • A cool response : the influence of ambient temperature on capillary refill time
  • 2018
  • Ingår i: Journal of Biophotonics. - : Wiley-VCH Verlagsgesellschaft. - 1864-063X .- 1864-0648. ; 11:6
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveTo describe the effect of low ambient temperature on skin temperature and capillary refill (CR) time in forehead, sternum and finger pulp.MethodsAn observational, nonrandomized experimental study on 15 healthy subjects (6 females) in a cold room (8°C). Outcome measures were skin temperature and quantified CR test after application of a standardized blanching pressure (9 N/cm2) using digital photographic polarization spectroscopy to generate CR times.ResultsThe finger pulp showed marked temperature fall and prolonged CR times (>10 seconds). The CR registrations of the forehead and sternum were more comparable to curves observed in a control material at room temperature, and skin temperature falls were less marked. CR times were not prolonged in forehead measurements. At the sternum, some individuals showed CR times beyond guideline recommendations despite only a marginal reduction in skin temperature.ConclusionsLow ambient temperature is a strong independent factor for CR time at peripheral sites. Reservation about sternum as a site of measurement is warranted since cold provocation produced prolonged CR times in some individuals. We found that the forehead is the most thermostable of the 3 sites and thus the preferred site to avoid ambient temperature artifact in measuring CR time.
  •  
6.
  • Wretborn, Jens, et al. (författare)
  • Risk of venous thromboembolism in patients with COVID-19 during 2020; a retrospective cross-sectional study in a Swedish health care system
  • 2023
  • Ingår i: Scientific Reports. - : NATURE PORTFOLIO. - 2045-2322. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • To establish the impact of COVID-19 on the pre-test probability for VTE in patients with suspected VTE. This was a retrospective, observational, cross-sectional study of patients 18 years and older undergoing diagnostic tests for VTE in an integrated healthcare system covering a population of 465,000 during the calendar year of 2020. We adjusted for risk factors such as age, sex, previous VTE, ongoing anticoagulant treatment, malignancy, Charlson score, ward care, ICU care and wave of COVID-19. In total, 303 of 5041 patients had a positive diagnosis of COVID-19 around the time of investigation. The prevalence of VTE in COVID-positive patients was 10.2% (36/354), 14.7% (473/3219) in COVID-19 negative patients, and 15.6% (399/2589) in patients without a COVID-19 test. A COVID-positive status was not associated with an increased risk for VTE (crude odds ratio 0.64, 95% CI 0.45-0.91, adjusted odds ratio 0.46, 95%CI 0.19-1.16). We found no increased VTE risk in COVID-positive patients. This indicates that COVID-19 status should not influence VTE workup.The study was pre-registered on May 26, 2020 at ClinicalTrials.gov with identifier NCT04400877.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy