SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Björklund Justina) "

Sökning: WFRF:(Björklund Justina)

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Björklund, Justina A., et al. (författare)
  • Comparisons of polybrominated diphenyl ether and hexabromocyclododecane concentrations in dust collected with two sampling methods and matched breast milk samples
  • 2012
  • Ingår i: Indoor Air. - : Hindawi Limited. - 0905-6947 .- 1600-0668. ; 22:4, s. 279-288
  • Tidskriftsartikel (refereegranskat)abstract
    • Household dust from 19 Swedish homes was collected using two different sampling methods: from the occupants own home vacuum cleaner after insertion of a new bag and using a researcher-collected method where settled house dust was collected from surfaces above floor level. The samples were analyzed for 16 polybrominated diphenyl ether (PBDE) congeners and total hexabromocyclododecane (HBCD). Significant correlations (r = 0.600.65, Spearman r = 0.470.54, P < 0.05) were found between matched dust samples collected with the two sampling methods for ?OctaBDE and ?DecaBDE but not for ?PentaBDE or HBCD. Statistically significantly higher concentrations of all PBDE congeners were found in the researcher-collected dust than in the home vacuum cleaner bag dust (VCBD). For HBCD, however, the concentrations were significantly higher in the home VCBD samples. Analysis of the bags themselves indicated no or very low levels of PBDEs and HBCD. This indicates that there may be specific HBCD sources to the floor and/or that it may be present in the vacuum cleaners themselves. The BDE-47 concentrations in matched pairs of VCBD and breast milk samples were significantly correlated (r = 0.514, P = 0.029), indicating that one possible exposure route for this congener may be via dust ingestion. Practical Implications The statistically significant correlations found for several individual polybrominated diphenyl ether (PBDE) congeners, ?OctaBDE and ?DecaBDE between the two dust sampling methods in this study indicate that the same indoor sources contaminate both types of dust or that common processes govern the distribution of these compounds in the indoor environment. Therefore, either method is adequate for screening ?OctaBDE and ?DecaBDE in dust. The high variability seen between dust samples confirms results seen in other studies. For hexabromocyclododecane (HBCD), divergent results in the two dust types indicate differences in contamination sources to the floor than to above-floor surfaces. Thus, it is still unclear which dust sampling method is most relevant for HBCD as well as for ?PentaBDE in dust and, further, which is most relevant for determining human exposure to PBDEs and HBCD.
  •  
4.
  • Björklund, Justina Awasum, et al. (författare)
  • Indoor Air Is a Significant Source of Tri-decabrominated Diphenyl Ethers to Outdoor Air via Ventilation Systems
  • 2012
  • Ingår i: Environmental Science and Technology. - : American Chemical Society (ACS). - 0013-936X .- 1520-5851. ; 46:11, s. 5876-5884
  • Tidskriftsartikel (refereegranskat)abstract
    • Ventilation of indoor air has been hypothesized to be a source of PBDEs to outdoors. To study this, tri-decabrominated diphenyl ethers were analyzed in outgoing air samples collected inside ventilation systems just before exiting 33 buildings and compared to indoor air samples from microenvironments in each building collected simultaneously. Median Sigma 10PBDE (BDE- 28, -47, -99, -153, -183, -197, -206, -207, -208, -209) concentrations in air from apartment, office and day care center buildings were 93, 3700, and 660 pg/m(3) for outgoing air, and 92, 4700, and 1200 pg/m(3) for indoor air, respectively. BDE-209 was the major congener found. No statistically significant differences were seen for individual PBDE concentrations in matched indoor and outgoing air samples, indicating that outgoing air PBDE concentrations are equivalent to indoor air concentrations. PBDE concentrations in indoor and outgoing air were higher than published outdoor air values suggesting ventilation as a conduit of PBDEs, including BDE-209, from indoors to outdoors. BDE-209 and sum of BDE-28, -47, -99, and -153 emissions from indoor air to outdoors were roughly estimated to represent close to 90% of total emissions to outdoor air for Sweden, indicating that contaminated indoor air is an important source of PBDE contamination to outdoor air.
  •  
5.
  • Björklund, Justina Awasum, et al. (författare)
  • Perfluoroalkyl compounds (PFCs) in indoor dust : concentrations, human exposure estimates, and sources
  • 2009
  • Ingår i: Environmental Science and Technology. - : American Chemical Society (ACS). - 0013-936X .- 1520-5851. ; 43:7, s. 2276-2281
  • Tidskriftsartikel (refereegranskat)abstract
    • Perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) are globally distributed, persistent, toxic, and are found in human blood and serum. Exposure pathways are not well characterized. To better understand indoor dust ingestion as a potential pathway for human exposure, we determined the concentrations of these compounds in dust collected from 10 houses, 38 apartments, 10 day care centers, 10 offices, and 5 cars. Samples were prepared using a rapid extraction and cleanup method and analyzed using LC-MS/MS. PFOS and PFOA were found in dust samples from all microenvironments and their concentrations were significantly positively correlated to each other. Highest median concentrations were seen in offices (PFOS: 110 ng/g dry weight) and apartments (PFOA: 93 ng/g dw). Adult and toddler dust ingestion exposures were estimated and compared to dietary exposure data from Canada and Spain. Results show that diet is the most important exposure route, but in a worst case scenario, dust ingestion may also be significant.
  •  
6.
  • Björklund, Justina Awasum, et al. (författare)
  • PFOS and PFOA in dust from Stockholm microenvironments.
  • 2008
  • Ingår i: The 28th International Symposium on Halogenated Persistent Organic Pollutants (Dioxin 2008), Birmingham, UK, 18-22 August 2008..
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
  •  
7.
  • Björklund, Justina, 1974- (författare)
  • Brominated flame retardants and perfluoroalkyl acids in Swedish indoor microenvironments : Implications for human exposure
  • 2011
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Humans are exposed to persistent organic pollutants (POPs) such as brominated flame retardants (BFRs, specifically polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD)) and perfluoroalkyl acids (PFAAs, specifically perfluoroalkane sulfonate (PFOS) and perfluorooctanoic acid (PFOA)). They are used in consumer products found in cars, offices, homes and day care centers. Diet was earlier thought to be a major human exposure route for legacy POPs, but does not account for body burdens found for many new POPs and indoor exposure from air and dust has been hypothesized as also important.In this thesis, BFRs in air and dust, and PFAAs in dust from different indoor microenvironments in Sweden were analysed, and the results used to estimate human exposure. BFRs and PFAAs were detected in dust from all microenvironments and PBDEs in all air samples. BFR and PFAA exposure occurs mostly in peoples’ homes with toddlers having higher intakes from dust ingestion than adults. Inhalation and dust ingestion play minor roles compared to diet for humans with median exposures, but in worst case scenarios, dust ingestion may be significant for a small part of the Swedish population. Sampling using home vacuum cleaner bag dust and researcher-collected above floor dust was compared. Correlations were seen for ∑OctaBDE and ∑DecaBDE but not for ∑PentaBDE and HBCD. Higher PBDE concentrations were found in above floor dust but higher HBCD concentrations were found in vacuum cleaner bag dust. BDE-47 concentrations were correlated between vacuum cleaner bag dust and breast milk, indicating exposure through dust ingestion.Similar concentrations of PBDEs were measured in indoor and outgoing air from day care centers, apartment and office buildings. Indoor air explained 54-92% of ∑PentaBDE and 24-86% of BDE-209 total emissions to outdoor air in Sweden, supporting the hypothesis that the indoor environment is polluting ambient air via ventilation systems.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy