SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Body T.) "

Sökning: WFRF:(Body T.)

  • Resultat 1-10 av 15
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Stroth, U., et al. (författare)
  • Progress from ASDEX Upgrade experiments in preparing the physics basis of ITER operation and DEMO scenario development
  • 2022
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 1741-4326 .- 0029-5515. ; 62:4
  • Tidskriftsartikel (refereegranskat)abstract
    • An overview of recent results obtained at the tokamak ASDEX Upgrade (AUG) is given. A work flow for predictive profile modelling of AUG discharges was established which is able to reproduce experimental H-mode plasma profiles based on engineering parameters only. In the plasma center, theoretical predictions on plasma current redistribution by a dynamo effect were confirmed experimentally. For core transport, the stabilizing effect of fast ion distributions on turbulent transport is shown to be important to explain the core isotope effect and improves the description of hollow low-Z impurity profiles. The L-H power threshold of hydrogen plasmas is not affected by small helium admixtures and it increases continuously from the deuterium to the hydrogen level when the hydrogen concentration is raised from 0 to 100%. One focus of recent campaigns was the search for a fusion relevant integrated plasma scenario without large edge localised modes (ELMs). Results from six different ELM-free confinement regimes are compared with respect to reactor relevance: ELM suppression by magnetic perturbation coils could be attributed to toroidally asymmetric turbulent fluctuations in the vicinity of the separatrix. Stable improved confinement mode plasma phases with a detached inner divertor were obtained using a feedback control of the plasma β. The enhanced D α H-mode regime was extended to higher heating power by feedback controlled radiative cooling with argon. The quasi-coherent exhaust regime was developed into an integrated scenario at high heating power and energy confinement, with a detached divertor and without large ELMs. Small ELMs close to the separatrix lead to peeling-ballooning stability and quasi continuous power exhaust. Helium beam density fluctuation measurements confirm that transport close to the separatrix is important to achieve the different ELM-free regimes. Based on separatrix plasma parameters and interchange-drift-Alfvén turbulence, an analytic model was derived that reproduces the experimentally found important operational boundaries of the density limit and between L- and H-mode confinement. Feedback control for the X-point radiator (XPR) position was established as an important element for divertor detachment control. Stable and detached ELM-free phases with H-mode confinement quality were obtained when the XPR was moved 10 cm above the X-point. Investigations of the plasma in the future flexible snow-flake divertor of AUG by means of first SOLPS-ITER simulations with drifts activated predict beneficial detachment properties and the activation of an additional strike point by the drifts.
  •  
2.
  • Neumann, J. T., et al. (författare)
  • Application of High-Sensitivity Troponin in Suspected Myocardial Infarction
  • 2019
  • Ingår i: New England Journal of Medicine. - : MASSACHUSETTS MEDICAL SOC. - 0028-4793 .- 1533-4406. ; 380:26, s. 2529-2540
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundData regarding high-sensitivity troponin concentrations in patients presenting to the emergency department with symptoms suggestive of myocardial infarction may be useful in determining the probability of myocardial infarction and subsequent 30-day outcomes. MethodsIn 15 international cohorts of patients presenting to the emergency department with symptoms suggestive of myocardial infarction, we determined the concentrations of high-sensitivity troponin I or high-sensitivity troponin T at presentation and after early or late serial sampling. The diagnostic and prognostic performance of multiple high-sensitivity troponin cutoff combinations was assessed with the use of a derivation-validation design. A risk-assessment tool that was based on these data was developed to estimate the risk of index myocardial infarction and of subsequent myocardial infarction or death at 30 days. ResultsAmong 22,651 patients (9604 in the derivation data set and 13,047 in the validation data set), the prevalence of myocardial infarction was 15.3%. Lower high-sensitivity troponin concentrations at presentation and smaller absolute changes during serial sampling were associated with a lower likelihood of myocardial infarction and a lower short-term risk of cardiovascular events. For example, high-sensitivity troponin I concentrations of less than 6 ng per liter and an absolute change of less than 4 ng per liter after 45 to 120 minutes (early serial sampling) resulted in a negative predictive value of 99.5% for myocardial infarction, with an associated 30-day risk of subsequent myocardial infarction or death of 0.2%; a total of 56.5% of the patients would be classified as being at low risk. These findings were confirmed in an external validation data set. ConclusionsA risk-assessment tool, which we developed to integrate the high-sensitivity troponin I or troponin T concentration at emergency department presentation, its dynamic change during serial sampling, and the time between the obtaining of samples, was used to estimate the probability of myocardial infarction on emergency department presentation and 30-day outcomes.
  •  
3.
  • Blain, H., et al. (författare)
  • A comprehensive fracture prevention strategy in older adults : the European union geriatric medicine society (EUGMS) statement
  • 2016
  • Ingår i: European Geriatric Medicine. - : Elsevier. - 1878-7649 .- 1878-7657. ; 7:6, s. 519-525
  • Tidskriftsartikel (refereegranskat)abstract
    • Prevention of fragility fractures in older people has become a public health priority, although the most appropriate and cost-effective strategy remains unclear. In the present statement, the Interest group on falls and fracture prevention of the European union geriatric medicine society (EUGMS), in collaboration with the International association of gerontology and geriatrics for the European region (IAGG-ER), the European union of medical specialists (EUMS), the Fragility fracture network (FFN), the International osteoporosis foundation (IOF) - European society for clinical and economic aspects of osteoporosis and osteoarthritis (ECCEO), outlines its views on the main points in the current debate in relation to the primary and secondary prevention of falls, the diagnosis and treatment of bone fragility, and the place of combined falls and fracture liaison services for fracture prevention in older people.
  •  
4.
  •  
5.
  • Aakre, K. M., et al. (författare)
  • Analytical Considerations in Deriving 99th Percentile Upper Reference Limits for High-Sensitivity Cardiac Troponin Assays: Educational Recommendations from the IFCC Committee on Clinical Application of Cardiac Bio-Markers
  • 2022
  • Ingår i: Clinical chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 68:8, s. 1022-1030
  • Tidskriftsartikel (refereegranskat)abstract
    • The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers provides evidence-based educational documents to facilitate uniform interpretation and utilization of cardiac biomarkers in clinical laboratories and practice. The committee's goals are to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay in clinical practice. Measurement of high-sensitivity cardiac troponin (hs-cTn) assays is a cornerstone in the clinical evaluation of patients with symptoms and/or signs of acute cardiac ischemia. To define myocardial infarction, the Universal Definition of Myocardial Infarction requires patients who manifest with features suggestive of acute myocardial ischemia to have at least one cTn concentration above the sex-specific 99th percentile upper reference limit (URL) for hs-cTn assays and a dynamic pattern of cTn concentrations to fulfill the diagnostic criteria for MI. This special report provides an overview of how hs-cTn 99th percentile URLs should be established, including recommendations about prescreening and the number of individuals required in the reference cohort, how statistical analysis should be conducted, optimal preanalytical and analytical protocols, and analytical/biological interferences or confounds that can affect accurate determination of the 99th percentile URLs. This document also provides guidance and solutions to many of the issues posed.
  •  
6.
  •  
7.
  •  
8.
  • Collinson, P., et al. (författare)
  • Cardiac troponin measurement at the point of care: educational recommendations on analytical and clinical aspects by the IFCC Committee on Clinical Applications of Cardiac Bio-Markers (IFCC C-CB)
  • 2023
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 61:6, s. 989-998
  • Tidskriftsartikel (refereegranskat)abstract
    • The International Federation of Clinical Chemistry and Laboarator Medicine (IFCC) Committee on Clinical Applications of Cardiac Bio-Markers (C-CB) has provided evidence-based educational resources to aid and improve the understanding of important analytical and clinical aspects of cardiac biomarkers. The present IFCC C-CB educational report focuses on recommendations for appropriate use, analytical performance, and gaps in clinical studies related to the use of cardiac troponin (cTn) by point of care (POC) measurement, often referred to as a point of care testing (POCT). The use of high-sensitivity (hs)-cTn POC devices in accelerated diagnostic protocols used in emergency departments or outpatient clinics investigating acute coronary syndrome has the potential for improved efficacy, reduction of length of stay and reduced costs in the health care system. POCT workflow integration includes location of the instrument, assignment of collection and testing responsibility to (non-lab) staff, instrument maintenance, in-service and recurrent training, quality control, proficiency assessments, discrepant result trapping, and troubleshooting and inventory management.
  •  
9.
  • Devogelaer, J. P., et al. (författare)
  • Zoledronic acid efficacy and safety over five years in postmenopausal osteoporosis
  • 2007
  • Ingår i: Osteoporosis International. - : Springer Science and Business Media LLC. - 1433-2965 .- 0937-941X. ; 18:9, s. 1211-1218
  • Tidskriftsartikel (refereegranskat)abstract
    • In a 5-year study involving 119 postmenopausal women, zoledronic acid 4 mg given once-yearly for 2, 3 or 5 years was well tolerated with no evidence of excessive bone turnover reduction or any safety signals. BMD increased significantly. Bone turnover markers decreased from baseline and were maintained within premenopausal reference ranges. Introduction After completion of the core study, two consecutive, 2-year, open-label extensions investigated the efficacy and safety of zoledronic acid 4 mg over 5 years in postmenopausal osteoporosis. Methods In the core study, patients received 1 to 4 mg zoledronic acid or placebo. In the first extension, most patients received 4 mg per year and then patients entered the second extension and received 4 mg per year or calcium only. Patients were divided into three subgroups according to years of active treatment received ( 2, 3 or 5 years). Changes in BMD and bone turnover markers ( bone ALP and CTX-I) were assessed. Results All subgroups showed substantial increases in BMD and decreases in bone markers. By the end of the core study, 37.5% of patients revealed a suboptimal reduction (< 30%) of bone ALP levels. After subsequent study drug administration during the extensions, there was no evidence of progressive reduction of bone turnover markers. Furthermore, increased marker levels after treatment discontinuation demonstrates preservation of bone remodelling capacity. Conclusions This study showed that zoledronic acid 4 mg once-yearly was well tolerated and effective in reducing biomarkers over 5 years. Detailed analysis of bone marker changes, however, suggests that this drug regimen causes insufficient reduction of remodelling activity in one third of patients.
  •  
10.
  • Hammarsten, Ola, et al. (författare)
  • Antibody-mediated interferences affecting cardiac troponin assays: recommendations from the IFCC Committee on Clinical Applications of Cardiac Biomarkers
  • 2023
  • Ingår i: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 61:8
  • Tidskriftsartikel (refereegranskat)abstract
    • The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy