SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Boeglin W. U.) "

Sökning: WFRF:(Boeglin W. U.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Kelly, J. J., et al. (författare)
  • Recoil polarization measurements for neutral pion electroproduction at Q(2)=1(GeV/c)(2) near the Delta resonance
  • 2007
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 75:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We measured angular distributions of differential cross section, beam analyzing power, and recoil polarization for neutral pion electroproduction at Q(2)=1.0 (GeV/c)(2) in 10 bins of 1.17 <= W <= 1.35 GeV across the Delta resonance. A total of 16 independent response functions were extracted, of which 12 were observed for the first time. Comparisons with recent model calculations show that response functions governed by real parts of interference products are determined relatively well near the physical mass, W=M-Delta approximate to 1.232 GeV, but the variation among models is large for response functions governed by imaginary parts, and for both types of response functions, the variation increases rapidly with W > M-Delta. We performed a multipole analysis that adjusts suitable subsets of center dot(pi)<= 2 amplitudes with higher partial waves constrained by baseline models. This analysis provides both real and imaginary parts. The fitted multipole amplitudes are nearly model independent-there is very little sensitivity to the choice of baseline model or truncation scheme. By contrast, truncation errors in the traditional Legendre analysis of N ->Delta quadrupole ratios are not negligible. Parabolic fits to the W dependence around M-Delta for the multiple analysis gives values for Re(S1+/M1+)=(-6.61 +/- 0.18)% and Re(E1+/M1+)=(-2.87 +/- 0.19)% for the p pi(0) channel at W=1.232 GeV and Q(2)=1.0 (GeV/c)(2) that are distinctly larger than those from the Legendre analysis of the same data. Similarly, the multipole analysis gives Re(S0+/M1+)=(+7.1 +/- 0.8)% at W=1.232 GeV, consistent with recent models, while the traditional Legendre analysis gives the opposite sign because its truncation errors are quite severe.
  •  
3.
  • Cecconello, Marco, et al. (författare)
  • Energetic ion behaviour in MAST
  • 2015
  • Ingår i: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 57:1, s. 014006-
  • Tidskriftsartikel (refereegranskat)abstract
    • Recent studies of fast ion transport resulting from a range of instabilities, including n = 1 internal kink modes (fishbones and long-lived modes), toroidal Alfven eigenmodes and sawteeth have been carried out at MAST. Strong correlations were found between relative changes in magnetic edge coils signals, edge D alpha signal a fast ion D alpha system, a prototype collimated neutron flux monitor and a recently installed prototype charged fusion product detector array, indicating both redistribution and loss of fast ions. Preliminary interpretation of these observations with a suite of stability, modelling and interpretative codes is discussed.
  •  
4.
  • Jones, O. M., et al. (författare)
  • Measurements and modelling of fast-ion redistribution due to resonant MHD instabilities in MAST
  • 2015
  • Ingår i: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 57:12
  • Tidskriftsartikel (refereegranskat)abstract
    • The results of a comprehensive investigation into the effects of toroidicity-induced Alfven eigenmodes (TAE) and energetic particle modes on the NBI-generated fast-ion population in MAST plasmas are reported. Fast-ion redistribution due to frequency-chirping TAE in the range 50 kHz-100 kHz and frequency-chirping energetic particle modes known as fishbones in the range 20 kHz-50 kHz, is observed. TAE and fishbones are also observed to cause losses of fast ions from the plasma. The spatial and temporal evolution of the fast-ion distribution is determined using a fission chamber, a radially-scanning collimated neutron flux monitor, a fast-ion deuterium alpha spectrometer and a charged fusion product detector. Modelling using the global transport analysis code TRANSP, with ad hoc anomalous diffusion and fishbone loss models introduced, reproduces the coarsest features of the affected fast-ion distribution in the presence of energetic particle-driven modes. The spectrally and spatially resolved measurements show, however, that these models do not fully capture the effects of chirping modes on the fast-ion distribution.
  •  
5.
  • McClements, K. G., et al. (författare)
  • The effects of resonant magnetic perturbations on fast ion confinement in the Mega Amp Spherical Tokamak
  • 2015
  • Ingår i: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 57:7
  • Tidskriftsartikel (refereegranskat)abstract
    • The effects of resonant magnetic perturbations (RMPs) on the confinement of energetic (neutral beam) ions in the Mega Amp Spherical Tokamak (MAST) are assessed experimentally using measurements of neutrons, fusion protons and fast ion D alpha (FIDA) light emission. In single null-diverted (SND) MAST pulses with relatively low plasma current (400 kA), the total neutron emission dropped by approximately a factor of two when RMPs with toroidal mode number n = 3 were applied. The measured neutron rate during RMPs was much lower than that calculated using the TRANSP plasma simulation code, even when non-classical (but axisymmetric) ad hoc fast ion transport was taken into account in the latter. Sharp drops in spatially-resolved neutron rates, fusion proton rates and FIDA emission were also observed. First principles-based simulations of RMP-induced fast ion transport in MAST, using the F3D-OFMC code, show similar losses for two alternative representations of the MAST first wall, with and without full orbit effects taken into account; for n = 6 RMPs in a 600 kA plasma, the additional loss of beam power due to the RMPs was found in the simulations to be approximately 11%.
  •  
6.
  • Perez, R. V., et al. (författare)
  • Investigating fusion plasma instabilities in the Mega Amp Spherical Tokamak using mega electron volt proton emissions
  • 2014
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 85:11, s. 11D701-
  • Tidskriftsartikel (refereegranskat)abstract
    • The proton detector (PD) measures 3 MeV proton yield distributions from deuterium-deuterium fusion reactions within the Mega Amp Spherical Tokamak (MAST). The PD's compact four-channel system of collimated and individually oriented silicon detectors probes different regions of the plasma, detecting protons (with gyro radii large enough to be unconfined) leaving the plasma on curved trajectories during neutral beam injection. From first PD data obtained during plasma operation in 2013, proton production rates (up to several hundred kHz and 1 ms time resolution) during sawtooth events were compared to the corresponding MAST neutron camera data. Fitted proton emission profiles in the poloidal plane demonstrate the capabilities of this new system.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy