SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bornefalk Hans) "

Sökning: WFRF:(Bornefalk Hans)

  • Resultat 1-10 av 68
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ahmadi, Zainab, et al. (författare)
  • Agreement of the modified Medical Research Council and New York Heart Association scales for assessing the impact of self-rated breathlessness in cardiopulmonary disease
  • 2022
  • Ingår i: ERJ Open Research. - : European Respiratory Society. - 2312-0541. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The functional impact of breathlessness is assessed using the modified Medical Research Council (mMRC) scale for chronic respiratory disease and with the New York Heart Association Functional Classification (NYHA) scale for heart failure. We evaluated agreement between the scales and their concurrent validity with other clinically relevant patient-reported outcomes in cardiorespiratory disease.Methods: Outpatients with stable chronic respiratory disease or heart failure were recruited. Agreement between the mMRC and NYHA scales was analysed using Cramér's V and Kendall's tau B tests. Concurrent validity was evaluated using correlations with clinically relevant measures of breathlessness, anxiety, depression, and health-related quality of life. Analyses were conducted for all participants and separately in chronic obstructive pulmonary disease (COPD) and heart failure.Results: In a total of 182 participants with cardiorespiratory disease, the agreement between the mMRC and NYHA scales was moderate (Cramér's V: 0.46; Kendall's tau B: 0.57) with similar results for COPD (Cramér's V: 0.46; Kendall's tau B: 0.66) and heart failure (Cramér's V: 0.46; Kendall's tau B: 0.67). In the total population, the scales correlated in similar ways to other patient-reported outcomes.Conclusion: In outpatients with cardiorespiratory disease, the mMRC and NYHA scales show moderate to strong correlations and similar associations with other patient-reported outcomes. This supports that the scales are comparable when assessing the impact of breathlessness on function and patient-reported outcomes.
  •  
2.
  • Bornefalk, Hans, et al. (författare)
  • On the comparison of FROC curves in mammography CAD systems
  • 2005
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 32:2, s. 412-417
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a novel method for assessing the performance of computer-aided detection systems on unseen cases at a given sensitivity level.
  •  
3.
  •  
4.
  • Ekström, Magnus, et al. (författare)
  • Minimal clinically important differences for Dyspnea-12 and MDP scores are similar at 2 weeks and 6 months : follow-up of a longitudinal clinical study
  • 2021
  • Ingår i: The European respiratory journal. - : European Respiratory Society (ERS). - 1399-3003 .- 0903-1936. ; 57:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Chronic breathlessness is a dominating symptom that restricts daily life for many people with cardiorespiratory disease [1]. Different dimensions of the symptom, such as the intensity, sensory qualities and emotional responses, can be assessed using the instruments Dyspnea-12 (D-12) [2] and the Multidimensional Dyspnea Profile (MDP) [3], which share similarities in the underlying constructs of what is measured [4] and have emerged as widely used instruments for multi-dimensional measurement of breathlessness
  •  
5.
  • Ekström, Magnus P., et al. (författare)
  • Minimal Clinically Important Differences and Feasibility of Dyspnea-12 and the Multidimensional Dyspnea Profile in Cardiorespiratory Disease
  • 2020
  • Ingår i: Journal of Pain and Symptom Management. - : Elsevier. - 0885-3924 .- 1873-6513. ; 60:5, s. 968-975
  • Tidskriftsartikel (refereegranskat)abstract
    • Context: Breathlessness is a cardinal symptom in cardiorespiratory disease and consists of multiple dimensions that can be measured using the instruments Dyspnea-12 (D12) and the Multidimensional Dyspnea Profile (MDP). Objectives: The objective of the study is to determine the minimal clinically important differences (MCIDs) of all D12 and MDP summary and subdomain scores as well as the instruments' feasibility in patients with cardiorespiratory disease. Methods: Prospective multicenter cohort study of outpatients with diagnosed cardiorespiratory disease and breathlessness in daily life. D12 and MDP were assessed at baseline, after 30-90 minutes and two weeks. MCIDs were calculated using anchor-based and distributional methods for summary and subdomain scores. Feasibility was assessed as rate of missing data, help required, self-reported difficulty, and completion time. Results: A total 182 outpatients (53.3% women) were included; main diagnoses were chronic obstructive pulmonary disease (COPD; 25%), asthma (21%), heart failure (19%), and idiopathic pulmonary fibrosis (19%). Anchor-based MCIDs were for D12 total score 2.83 (95% CI 1.99-3.66); D12 physical 1.81 (1.29-2.34); D12 affective 1.07 (0.64-1.49); MDP A1 unpleasantness 0.82 (0.56-1.08); MDP perception 4.63 (3.21-6.05), and MDP emotional score 2.37 (1.10-3.64). The estimates were consistent with small-to-moderate effect sizes using distributional analysis, and MCIDs were similar between COPD and non-COPD patients. The instruments were generally feasible and quick to use. Conclusion: D12 and MDP are responsive to change and feasible for use for assessing multidimensional breathlessness in outpatients with cardiorespiratory disease. MCIDs were determined for use as endpoints in clinical trials.
  •  
6.
  • Ekström, Magnus, et al. (författare)
  • Validation of the Swedish Multidimensional Dyspnea Profile (MDP) in outpatients with cardiorespiratory disease
  • 2019
  • Ingår i: BMJ Open Respiratory Research. - : BMJ. - 2052-4439. ; 6:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction Breathlessness is a cardinal symptom in cardiorespiratory disease. An instrument for measuring different aspects of breathlessness was recently developed, the Multidimensional Dyspnea Profile (MDP). This study aimed to validate the MDP in terms of the underlying factor structure, internal consistency, test-retest reliability and concurrent validity in Swedish outpatients with cardiorespiratory disease. Methods Outpatients with stable cardiorespiratory disease and breathlessness in daily life were recruited. Factor structure of MDP was analysed using confirmatory factor analysis; internal consistency was analysed using Cronbach's alpha; and test-retest reliability was analysed using intraclass correlation coefficients (ICCs) for patients with unchanged breathlessness between assessments (baseline, after 30-90 min and 2 weeks). Concurrent validity was evaluated using correlations with validated scales of breathlessness, anxiety, depression and health-related quality of life. Results In total, 182 outpatients with cardiorespiratory disease and breathlessness in daily life were included; 53.3% were women; main diagnoses were chronic obstructive pulmonary disease (24.7%), asthma (21.4%), heart failure (19.2%) and idiopathic pulmonary fibrosis (18.7%). The MDP total, immediate perception and emotional response scores, and individual item scores showed expected factor structure and acceptable measurement properties: internal consistency (Cronbach's alpha, range 0.80-0.93); test-retest reliability at 30-90 min and 2 weeks (ICC, range 0.67-0.91); and concurrent validity. There was no evidence of a learning effect. Findings were similar between diagnoses. Discussion MDP is a valid instrument for multidimensional measurement of breathlessness in Swedish outpatients across cardiorespiratory diseases.
  •  
7.
  • Sundh, Josefin, 1972-, et al. (författare)
  • Clinical validation of the Swedish version of Dyspnoea-12 instrument in outpatients with cardiorespiratory disease
  • 2019
  • Ingår i: BMJ Open Respiratory Research. - : BMJ. - 2052-4439. ; 6:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction Breathlessness is the cardinal symptom in both cardiac and respiratory diseases, and includes multiple dimensions. The multidimensional instrument Dyspnoea-12 has been developed to assess both physical and affective components of breathlessness. This study aimed to perform a clinical validation of the Swedish version of Dyspnoea-12 in outpatients with cardiorespiratory disease. Methods Stable outpatients with cardiorespiratory disease and self-reported breathlessness in daily life were recruited from five Swedish centres. Assessments of Dyspnoea-12 were performed at baseline, after 30-90 min and after 2 weeks. Factor structure was tested using confirmatory factor analysis and internal consistency using Cronbach's alpha. Test-retest reliability was analysed using intraclass correlation coefficients (ICCs). Concurrent validity at baseline was evaluated by examining correlations with lung function and several instruments for the assessment of symptoms and health status. Results In total, 182 patients were included: with the mean age of 69 years and 53% women. The main causes of breathlessness were chronic obstructive pulmonary disease (COPD; 25%), asthma (21%), heart failure (19%) and idiopathic pulmonary fibrosis (19%). Factor analysis confirmed the expected underlying two-component structure with two subdomains. The Dyspnoea-12 total score, physical subdomain score and affective subdomain scores showed high internal consistency (Cronbach's alpha 0.94, 0.84 and 0.80, respectively) and acceptable reliability after 2 weeks (ICC total scores 0.81, 0.79 and 0.73). Dyspnoea-12 showed concurrent validity with the instruments modified Medical Research Council scale, COPD Assessment Test, European Quality of Life-Five Dimensions-Five levels, the Functional Assessment of Chronic Illness Therapy-Fatigue, the Hospital Anxiety and Depression Scale, and with forced expiratory volume in 1 s in percentage of predicted value. The results were consistent across different cardiorespiratory conditions. Conclusion The Dyspnoea-12 is a valid instrument for multidimensional assessment of breathlessness in Swedish patients with cardiorespiratory diseases.
  •  
8.
  • Bornefalk, Hans, 1974-, et al. (författare)
  • Allowable forward model misspecification for accurate basis decomposition in a silicon detector based spectral CT
  • 2015
  • Ingår i: IEEE Transactions on Medical Imaging. - : IEEE Press. - 0278-0062 .- 1558-254X. ; 34:3, s. 788-795
  • Tidskriftsartikel (refereegranskat)abstract
    • Material basis decomposition in the sinogram domain requires accurate knowledge of the forward model in spectral computed tomography (CT). Misspecifications over a certain limit will result in biased estimates and make quantum limited (where statistical noise dominates) quantitative CT difficult. We present a method whereby users can determine the degree of allowed misspecification error in a spectral CT forward model and still have quantification errors that are limited by the inherent statistical uncertainty. For a particular silicon detector based spectral CT system, we conclude that threshold determination is the most critical factor and that the bin edges need to be known to within 0.15 keV in order to be able to perform quantum limited material basis decomposition. The method as such is general to all multibin systems.
  •  
9.
  • Bornefalk, Hans, et al. (författare)
  • Calibration of an x-ray imaging system
  • 2022
  • Patent (populärvet., debatt m.m.)abstract
    • Disclosed is a calibration phantom for an x-ray imaging system having an x-ray source and an x-ray detector. The calibration phantom includes a combination of geometric objects of at least three different types and/or compositions including: a first object located in the middle, including a first material; a plurality of second objects arranged around the periphery of the first object, at least a subset of the second objects including a second material different than the first material, wherein the first object is relatively larger than the second objects; a plurality of third objects arranged around the periphery of the first object and/or around the periphery of at least a subset of the second objects, at least a subset of the third objects including a third material different than the first material and the second material, wherein the third objects are relatively smaller than the second objects.
  •  
10.
  • Bornefalk, Hans (författare)
  • Computer-aided detection and novel mammography imaging techniques
  • 2006
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • This thesis presents techniques constructed to aid the radiologists in detecting breast cancer, the second largest cause of cancer deaths for western women. In the first part of the thesis, a computer-aided detection (CAD) system constructed for the detection of stellate lesions is presented. Different segmentation methods and an attempt to incorporate contra-lateral information are evaluated. In the second part, a new method for evaluating such CAD systems is presented based on constructing credible regions for the number of false positive marks per image at a certain desired target sensitivity. This method shows that the resulting regions are rather wide and this explains some of the difficulties encountered by other researchers when trying to compare CAD algorithms on different data sets. In this part an attempt to model the clinical use of CAD as a second look is also made and it shows that applying CAD in sequence to the radiologist in a routine manner, without duly altering the decision criterion of the radiologist, might very well result in suboptimal operating points. Finally, in the third part two dual-energy imaging methods optimized for contrast-enhanced imaging of breast tumors are presented. The first is based on applying an electronic threshold to a photon-counting digital detector to discriminate between high- and low-energy photons. This allows simultaneous acquisition of the high- and low-energy images. The second method is based on the geometry of a scanned multi-slit system and also allows single-shot contrast-enhanced dual-energy mammography by filtering the x-ray beam that reaches different detector lines differently.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 68
Typ av publikation
tidskriftsartikel (39)
konferensbidrag (18)
patent (5)
doktorsavhandling (4)
annan publikation (2)
konstnärligt arbete (1)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (55)
övrigt vetenskapligt/konstnärligt (8)
populärvet., debatt m.m. (5)
Författare/redaktör
Bornefalk, Hans (63)
Danielsson, Mats (30)
Xu, Cheng (19)
Persson, Mats (18)
Karlsson, Staffan (15)
Danielsson, Mats, Pr ... (9)
visa fler...
Chen, Han (9)
Liu, Xuejin (9)
Svensson, Christer (8)
Persson, Mats, 1987- (8)
Grönberg, Fredrik (6)
Sandberg, Jacob (5)
Blomberg, Anders, 19 ... (5)
Bornefalk Hermansson ... (5)
Ekström, Magnus (4)
Sundh, Josefin, 1972 ... (4)
Igelström, Helena, 1 ... (4)
Janson, Christer (3)
Lundqvist, Mats (3)
Andersson, Henrik (2)
Andersson, Jonas (2)
Sköld, Magnus (2)
Bujila, Robert (2)
Jansson, Christer (2)
Bornefalk, Hans, 197 ... (2)
Hemmendorff, Magnus (2)
Kull, Love (2)
Sköld, C Magnus (2)
Yao, Y. (1)
Ahmadi, Zainab (1)
Bornefalk Hermansson ... (1)
Currow, David C (1)
Holmin, Staffan (1)
Svensson, Christer, ... (1)
Sundh, Josefin (1)
Nishikawa, Robert, P ... (1)
Hjärn, Torbjörn (1)
Hjarn, Torbjorn (1)
Lewin, John H. (1)
Hermansson, Anna Bor ... (1)
Lewin, John M. (1)
Yao, Yuan (1)
Chen, Han, 1986- (1)
Johnson, Miriam J. (1)
Crafoord, Joakim (1)
Huber, Benjamin (1)
Sköld, Carl Magnus (1)
Ekström, Magnus P. (1)
Meyer, Bettina (1)
Hsieh, Scott S. (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (62)
Linköpings universitet (8)
Uppsala universitet (7)
Umeå universitet (6)
Karolinska Institutet (6)
Lunds universitet (5)
visa fler...
Örebro universitet (4)
visa färre...
Språk
Engelska (67)
Odefinierat språk (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (28)
Naturvetenskap (24)
Teknik (13)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy