SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bouchelouche Kirsten) "

Sökning: WFRF:(Bouchelouche Kirsten)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Harms, Hendrik Johannes, et al. (författare)
  • Automatic extraction of forward stroke volume using dynamic PET/CT : a dual-tracer and dual-scanner validation in patients with heart valve disease.
  • 2015
  • Ingår i: EJNMMI Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 2:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners.METHODS: 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR).RESULTS: FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p < 0.001 for all). FSV based on (11)C-acetate and (15)O-water correlated highly (r = 0.99, slope = 1.03) with no significant difference between FSV estimates (p = 0.14).CONCLUSIONS: FSV can be obtained automatically using dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation.
  •  
2.
  • Harms, Hendrik Johannes, et al. (författare)
  • Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET
  • 2016
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 57:9, s. 1382-1387
  • Tidskriftsartikel (refereegranskat)abstract
    • Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. Methods: Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min C-11-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K-1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K-1 images to derive functional assessments of LV mass (m(LV)) and wall thickness. End systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. Results: High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland Altman analyses showed significant differences for m(LV) and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. Conclusion: LV mass and volume are accurately and automatically generated from dynamic C-11-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers.
  •  
3.
  • Hoff, Camilla M, et al. (författare)
  • Activity regimes for 82Rb cardiac PET : Effects on absolute MBF and MPI.
  • 2022
  • Ingår i: Journal of Nuclear Cardiology. - : Springer Nature. - 1071-3581 .- 1532-6551. ; 29:2, s. 449-460
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Selection of optimal tracer activity for 82Rb PET is based on a trade-off between necessary count-statistics in the late static phase and detector saturation in the early blood-pool phase. Administered tracer activity recommended in prescribing information differs substantially from recommendations in current literature. The present study examines the effect on both absolute myocardial blood flow (MBF), myocardial flow reserve (MFR) and relative myocardial perfusion imaging (MPI) of reducing dose.METHODS: Forty patients were scanned twice on a PMT-based PET/CT (GE D690): At recommended activity (1110 MBq) and at either 740 or 370 MBq. MBF, MFR, total perfusion deficit (TPD) and ejection fractions (EF) were quantified. Results were compared using linear regression and Bland-Altman plots.RESULTS: Linear correlation between MBF at 1110 MBq at either reduced activity had an R2 > 0.98. A small bias (± 5%-9%) was observed with opposite signs for 1110/740 and 1110/370. Limits of agreement for MBF were larger for 1110/370. MFR had a lower linear correlation (R2 = 0.96), but wide limits of agreement especially for 1110/370. TPD and EF correlated well at 1110/740 (R2 = 0.96 and 0.99, respectively), but large scatter was observed for 1110/370.CONCLUSION: Reduction of the tracer activity to 740 MBq, significantly reduced dead-time correction factors, while still producing reliable static and gated images. However, despite large dead-time at 1110 MBq, no systematic bias on absolute MBF was observed compared to reduced activities.
  •  
4.
  • Hoff, Camilla Molich, et al. (författare)
  • Quantitative and qualitative comparison of Rubidium-82 and Oxygen-15 water cardiac PET.
  • 2024
  • Ingår i: Journal of Nuclear Cardiology. - 1071-3581 .- 1532-6551. ; , s. 101796-
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Differences in tracer characteristics may influence the interpretation of positron emission tomography myocardial perfusion imaging (MPI). We compare the reading of MPIs with a low-extraction retention tracer (82Rb) and a high-extraction non-retention tracer (15O-water) in a selected cohort of patients with known coronary artery disease (CAD).METHODS: Thirty-nine patients with known CAD referred to 82Rb MPI due to angina underwent rest and stress imaging with both tracers and experienced MPI readers provided blinded consensus reads of all studies. In addition, a comparison of regional and global quantitative measures of perfusion was performed.RESULTS: The results showed 74 % agreement in the reading of 82Rb and 15O-water MPI for regional reversible ischemia and global disease, and 82 % agreement for regional irreversible ischemia. The 15O-water MPI identified more cases of global disease (n = 12 (15O-water) vs n = 4 (82Rb), p = 0.03), whereas differences in reversible ischemia (n = 22 vs n = 16, p = 0.11) and, irreversible ischemia (n = 8 vs n = 11, p = 0.45) were not significant. The correlation between myocardial blood flow measured using the two tracers was similar to previous studies (R2 = 0.78) with wide limits of agreement (-0.93 to 0.84 ml/g/min).CONCLUSIONS: Agreement between consensus readings of 82Rb and 15O-water MPI was good in patients with known CAD. In this limited size study, no significant differences in the identification of reversible and irreversible ischemia found, whereas 15O-water MPI had a higher positive rate for suspected global disease.
  •  
5.
  • Jochumsen, Mads Ryo, et al. (författare)
  • Potential synergy between PSMA uptake and tumour blood flow for prediction of human prostate cancer aggressiveness
  • 2021
  • Ingår i: EJNMMI Research. - : Springer Nature. - 2191-219X. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Both prostate-specific membrane antigen (PSMA) uptake and tumour blood flow (TBF) correlate with International Society of Urological Pathology (ISUP) Grade Group (GG) and hence prostate cancer (PCa) aggressiveness. The aim of the present study was to evaluate the potential synergistic benefit of combining the two physiologic parameters for separating significant PCa from insignificant findings. Methods From previous studies of [Rb-82]Rb positron emission tomography (PET) TBF in PCa, the 43 patients that underwent clinical [Ga-68]Ga-PSMA-11 PET were selected for this retrospective study. Tumours were delineated on [Ga-68]Ga-PSMA-11 PET or magnetic resonance imaging. ISUP GG was recorded from 52 lesions. Results [Ga-68]Ga-PSMA-11 maximum standardized uptake value (SUVmax) and [Rb-82]Rb SUVmax correlated moderately with ISUP GG (rho = 0.59 and rho = 0.56, both p < 0.001) and with each other (r = 0.65, p < 0.001). A combined model of [Ga-68]Ga-PSMA-11 and [Rb-82]Rb SUVmax separated ISUP GG > 2 from ISUP GG 1-2 and benign with an area-under-the-curve of 0.85, 96% sensitivity, 74% specificity, and 95% negative predictive value. The combined model performed significantly better than either tracer alone did (p < 0.001), primarily by reducing false negatives from five or six to one (p <= 0.025). Conclusion PSMA uptake and TBF provide complementary information about tumour aggressiveness. We suggest that a combined analysis of PSMA uptake and TBF could significantly improve the negative predictive value and allow non-invasive separation of significant from insignificant PCa.
  •  
6.
  • Tolbod, Lars P., et al. (författare)
  • Non-invasive quantification of tumor blood flow in prostate cancer using O-15-H2O PET/CT
  • 2018
  • Ingår i: American Journal of Nuclear Medicine and Molecular Imaging. - : E-CENTURY PUBLISHING CORP. - 2160-8407. ; 8:5, s. 292-302
  • Tidskriftsartikel (refereegranskat)abstract
    • Tumor blood flow (TBF) measurements in prostate cancer (PCa) provide an integrative index of tumor growth, which could be important for primary diagnosis and therapy response evaluation. O-15-water PET is the noninvasive gold standard but is technically demanding. The aim of this study was to compare the accuracy of three different non-invasive strategies with an invasively measured arterial input function (BSIF): Using image-derived input functions (IDIF) from either 1) a separate heart scan or 2) the pelvic scan or 3) a populations-based input function (PBIF). Nine patients with biopsy-verified PCa scheduled for prostatectomy were included. All patients were characterized with serum levels of PSA (s-PSA), multiparametric magnetic resonance imaging (mpMRl) and post-surgical histopathology Gleason Grade. Dynamic O-15-water was performed of the heart and the pelvic area 15 minutes apart. TBF estimated from both wash-in (K-1) and wash-out (k(2)) constants was calculated using a one-compartmental model. Results: Mean (range) s PSA was 12 (3-27) ng/mL, Gleason Grade Group was 2.9 (1-5), k(2) was 0.44 (0.007-1.2), and K-1 was 0.24 (0.07-0.55) mL,/mL/min. k(2) (BSIF)correlated with s-PSA (r=0.86, P<0.01) and Gleason Grade Group (rho=0.78, P=0.01). BSIF, heart-IDIF and PBIF provided near-identical k(2) and K-1 (r>0.95, P<0.001) with slopes near unity. The correlations of BSIF and pelvic-IDIF rate constants were good (r>0.95, P<0.001), but individual errors high. In conclusion, non-invasive protocols for O-15-water PET with IDIF or PBIF accurately measures perfusion in prostate cancer and might be useful for evaluation of tumor aggressiveness and treatment response.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy