SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brunkwall J.) "

Sökning: WFRF:(Brunkwall J.)

  • Resultat 1-10 av 39
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Veith, Frank J., et al. (författare)
  • Collected world and single center experience with endovascular treatment of ruptured abdominal aortic aneurysms
  • 2009
  • Ingår i: Annals of Surgery. - 0003-4932 .- 1528-1140. ; 250:5, s. 818-824
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Case and single center reports have documented the feasibility and suggested the effectiveness of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs), but the role and value of such treatment remain controversial. OBJECTIVE: To clarify these we examined a collected experience with use of EVAR for RAAA treatment from 49 centers. METHODS: Data were obtained by questionnaires from these centers, updated from 13 centers committed to EVAR treatment whenever possible and included treatment details from a single center and information on 1037 patients treated by EVAR and 763 patients treated by open repair (OR). RESULTS: Overall 30-day mortality after EVAR in 1037 patients was 21.2%. Centers performing EVAR for RAAAs whenever possible did so in 28% to 79% (mean 49.1%) of their patients, had a 30-day mortality of 19.7% (range: 0%-32%) for 680 EVAR patients and 36.3% (range: 8%-53%) for 763 OR patients (P < 0.0001). Supraceliac aortic balloon control was obtained in 19.1% +/- 12.0% (+/-SD) of 680 EVAR patients. Abdominal compartment syndrome was treated by some form of decompression in 12.2% +/- 8.3% (+/-SD) of these EVAR patients. CONCLUSION: These results indicate that EVAR has a lower procedural mortality at 30 days than OR in at least some patients and that EVAR is better than OR for treating RAAA patients provided they have favorable anatomy; adequate skills, facilities, and protocols are available; and optimal strategies, techniques, and adjuncts are employed.
  •  
3.
  • Brunkwall, J., et al. (författare)
  • Endovascular Repair of Acute Uncomplicated Aortic Type B Dissection Promotes Aortic Remodelling: 1 Year Results of the ADSORB Trial
  • 2014
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 48:3, s. 285-291
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Uncomplicated acute type B aortic dissection (AD) treated conservatively has a 10% 30-day mortality and up to 25% need intervention within 4 years. In complicated AD, stent grafts have been encouraging. The aim of the present prospective randomised trial was to compare best medical treatment (BMT) with BMT and Gore TAG stent graft in patients with uncomplicated AD. The primary endpoint was a combination of incomplete/no false lumen thrombosis, aortic dilatation, or aortic rupture at 1 year. Methods: The AD history had to be less than 14 days, and exclusion criteria were rupture, impending rupture, malperfusion. Of the 61 patients randomised, 80% were DeBakey type IIIB. Results: Thirty-one patients were randomised to the BMT group and 30 to the BMT+TAG group. Mean age was 63 years for both groups. The left subclavian artery was completely covered in 47% and in part in 17% of the cases. During the first 30 days, no deaths occurred in either group, but there were three crossovers from the BMT to the BMT TAG group, all due to progression of disease within 1 week. There were two withdrawals from the BMT+TAG group. At the 1-year follow up there had been another two failures in the BMT group: one malperfusion and one aneurysm formation (p = .056 for all). One death occurred in the BMT TAG group. For the overall endpoint BMT+TAG was significantly different from BMT only (p < .001). Incomplete false lumen thrombosis, was found in 13 (43%) of the TAG+BMT group and 30 (97%) of the BMT group (p < .001). The false lumen reduced in size in the BMT+TAG group (p < .001) whereas in the BMT group it increased. The true lumen increased in the BMT TAG (p < .001) whereas in the BMT group it remained unchanged. The overall transverse diameter was the same at the beginning and after 1 year in the BMT group (42.1 mm), but in the BMT+TAG it decreased (38.8 mm; p = .062). Conclusions: Uncomplicated AD can be safely treated with the Gore TAG device. Remodelling with thrombosis of the false lumen and reduction of its diameter is induced by the stent graft, but long term results are needed. (C) 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
  •  
4.
  • Grenville, Z. S., et al. (författare)
  • Diet and BMI Correlate with Metabolite Patterns Associated with Aggressive Prostate Cancer
  • 2022
  • Ingår i: Nutrients. - : MDPI AG. - 2072-6643. ; 14:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Three metabolite patterns have previously shown prospective inverse associations with the risk of aggressive prostate cancer within the European Prospective Investigation into Cancer and Nutrition (EPIC). Here, we investigated dietary and lifestyle correlates of these three prostate cancer-related metabolite patterns, which included: 64 phosphatidylcholines and three hydroxysphingomyelins (Pattern 1), acylcarnitines C18:1 and C18:2, glutamate, ornithine, and taurine (Pattern 2), and 8 lysophosphatidylcholines (Pattern 3). In a two-stage cross-sectional discovery (n = 2524) and validation (n = 518) design containing 3042 men free of cancer in EPIC, we estimated the associations of 24 dietary and lifestyle variables with each pattern and the contributing individual metabolites. Associations statistically significant after both correction for multiple testing (False Discovery Rate = 0.05) in the discovery set and at p < 0.05 in the validation set were considered robust. Intakes of alcohol, total fish products, and its subsets total fish and lean fish were positively associated with Pattern 1. Body mass index (BMI) was positively associated with Pattern 2, which appeared to be driven by a strong positive BMI-glutamate association. Finally, both BMI and fatty fish were inversely associated with Pattern 3. In conclusion, these results indicate associations of fish and its subtypes, alcohol, and BMI with metabolite patterns that are inversely associated with risk of aggressive prostate cancer.
  •  
5.
  • Malina, Martin, et al. (författare)
  • Endovascular healing is inadequate for fixation of Dacron stent-grafts in human aortoiliac vessels
  • 2000
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 19:1, s. 5-11
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: migration and kinking of stent-grafts can occur late after endovascular aneurysm repair. It is unknown if endovascular grafts incorporate enough to be permanently anchored. In this report, healing of aortic stent-grafts was assessed in humans. PATIENTS AND METHODS: we retrieved 23 Dacron stent-grafts from patients treated for an aortic aneurysm since 1993. Twelve stent-grafts were explanted at late conversion to open repair and 11 at autopsy. The deaths were unrelated to graft fixation. The median age of the patients was 74 years (IQR 55-84 years) and the grafts were explanted 9 months (1-31 months) after insertion. Microscopic slides were prepared by conventional techniques or by cutting and grinding arterial specimens embedded in plastic with the stent-grafts in situ. RESULTS: the stent-grafts detached readily from the native arteries at surgery or autopsy, except when the stents had hooks or barbs which engaged the vessel wall. A space filled with poorly organised blood components persisted between the graft and the aortic wall 2.5 years after implantation. No firm incorporation of the grafts was observed proximally in the aneurysm neck or distally in the iliac segment. A friable neo-intimal layer covered parts of the luminal aspect of the grafts. CONCLUSIONS: endovascular healing provides poor fixation of Dacron stent-grafts in humans. At present, fixation relies on the mechanical properties of the stent-grafts.
  •  
6.
  • Verhoeven, E. L. G., et al. (författare)
  • Real-world Performance of the New C3 Gore Excluder Stent-Graft : 1-year Results from the European C3 Module of the Global Registry for Endovascular Aortic Treatment (GREAT)
  • 2014
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 48:2, s. 131-137
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) provides "real-world" outcomes for the new C3 Gore Excluder stent-graft, and evaluates the new deployment mechanism. This report presents the 1-year results from 400 patients enrolled in this registry. Methods: Between August 2010 and December 2012, 400 patients (86.8% male, mean age 73.9 +/- 7.8 years) from 13 European sites were enrolled in this registry. Patient demographics, treatment indication, case planning, operative details including repositioning and technical results, and clinical outcome were analyzed. Results: Technical success was achieved in 396/400 (99%) patients. Two patients needed intraoperative open conversion, one for iliac rupture, the second because the stent-graft was pulled down during a cross-over catheterization in an angulated anatomy. Two patients required an unplanned chimney renal stent to treat partial coverage of the left renal artery because of upward displacement of the stent-graft. Graft repositioning occurred in 192/399 (48.1%) patients, most frequently for level readjustment with regard to the renal arteries, and less commonly for contralateral gate reorientation. Final intended position of the stent-graft below the renal arteries was achieved in 96.2% of patients. Thirty-day mortality was two (0.5%) patients. Early reintervention (<= 30 days) was required in two (0.5%) patients. Mean follow-up duration was 15.9 +/- 8.8 months (range 0-37 months). Late reintervention (>30 days) was required in 26 (6.5%) patients. Estimated freedom from reintervention at 1 year was 95.2% (95% CI 92.3-97%), and at 2 years 91.5% (95% CI 86.8-94.5%). Estimated patient survival at 1 year was 96% (95% CI 93.3-97.6%) and at 2 years 90.6% (95% CI 85.6-93.9%). Conclusions: Early real-world experience shows that the new C3 delivery system offers advantages in terms of device repositioning resulting in high deployment accuracy. Longer follow-up is required to confirm that this high deployment accuracy results in improved long-term durability.
  •  
7.
  • Greenberg, R, et al. (författare)
  • Endovascular repair of descending thoracic aortic aneurysms: an early experience with intermediate-term follow-up
  • 2000
  • Ingår i: Journal of Vascular Surgery. - 1097-6809. ; 31:1 Pt 1, s. 147-156
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The purpose of this study was to report an initial experience with the endovascular repair of descending thoracic aortic aneurysm. Complications and intermediate-term morphologic changes were identified with the intent of altering patient selection and device design. METHODS: Endografts were placed into 25 patients at high-risk for conventional surgical repair over a 3(1/2)-year period. Devices were customized on the basis of preoperative imaging information. Follow-up computed tomography scans were obtained at 1, 3, 6, and 12 months and yearly thereafter. Additional interventions occurred in the setting of endoleaks, migration, and aneurysm growth. RESULTS: The overall 30-day mortality rate was 20% (12.5% for elective cases; 33% for emergent cases). There were 3 conversions to open repair. Neurologic deficits developed in 3 patients; 1 insult resulted in permanent paraplegia. Neurologic deficits were associated with longer endografts (P =.019). Three endoleaks required treatment, and 1 fatal rupture of the thoracic aneurysm treated occurred 6 months after the initial repair. Migrations were detected in 4 patients. The maximal aneurysm size decreased yearly by 9.15% (P =.01) or by 13.5% (P =.0005) if patients with endoleaks (n = 3 patients) were excluded. Both the proximal and distal neck dilated slightly over the course of follow-up (P =.019 and P =.001, respectively). The length of the proximal neck was a significant predictor of the risk for endoleakage (P =.02). CONCLUSION: The treatment of descending thoracic aortic aneurysms with an endovascular approach is feasible and may, in some patients, offer the best means of therapy. Early complications were primarily related to device design and patient selection. All aneurysms without endoleaks decreased in size after treatment. Late complications were associated with changing aneurysm morphologic features and device migration. The morphologic changes remain somewhat unpredictable; however, alterations in device design may result in improved fixation and more durable aneurysm exclusion.
  •  
8.
  • Heckenkamp, J, et al. (författare)
  • Photodynamic therapy reduces intimal hyperplasia in prosthetic vascular bypass grafts in a pig model.
  • 2007
  • Ingår i: European journal of vascular and endovascular surgery. - : Elsevier BV. - 1078-5884. ; 34:3, s. 333-9
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Bypass surgery has a failing frequency of 30% during the first year, mainly due to intimal hyperplasia (IH). This negative effect is most pronounced in artificial grafts. Photodynamic therapy (PDT) is a technique in which light activates photosensitizer dyes to produce free-radicals resulting in an eradication of cells in the vascular wall. The aim of this study was to determine the effectiveness of PDT to reduce IH in a preclinical porcine PTFE bypass model. MATERIAL AND METHODS: Ten pigs were used. After a pilot PDT dosimetry study (n=3) PTFE grafts were bilaterally placed into the circulation as bypasses from the common to the external iliac arteries (n=7). The right sides served as controls (C). Before implantation of the left grafts, the arterial connecting sites of the left distal anastomoses were PDT-treated. The arteries were pressurized at 180 mmHg for 5 minutes with the photosensitizer Methylene Blue (330 microg/ml), and thereafter endoluminally irradiated with laser light (lambda = 660 nm, 100 mW/cm(2), 150 J/cm(2)). After 4 weeks the specimens were retrieved and formalin fixed. Cross sections through the midportions of the distal anastomoses and the grafts were used for histology, immunohistochemistry to identify inflammatory cells and morphometric evaluation (n=7). RESULTS: No systemic side effects and no graft occlusions were noted. PDT-treated anastomoses showed reduced IH in the mid-portions of the anastomoses (Area of IH: microm(2)/microm graft: C: 6970+/-1536, PDT: 2734+/-2560; P<0.005) as well as in the grafts (C: 5391+/-4031, PDT: 777+/-1331; P<0.02). The number of inflammatory cells per microscopic field was increased after PDT (C: 24+/-16, PDT: 37+/-15; P<0.009). CONCLUSIONS: Adjuvant PDT, performed in an endovascular fashion, was a safe method to reduce prosthetic graftstenosis in a preclinical setting. This study underscores the clinical potential of PDT to inhibit the development of clinical bypass graftstenosis.
  •  
9.
  • Landais, E., et al. (författare)
  • Coffee and Tea Consumption and the Contribution of Their Added Ingredients to Total Energy and Nutrient Intakes in 10 European Countries: Benchmark Data from the Late 1990s
  • 2018
  • Ingår i: Nutrients. - : MDPI AG. - 2072-6643. ; 10:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Coffee and tea are among the most commonly consumed nonalcoholic beverages worldwide, but methodological differences in assessing intake often hamper comparisons across populations. We aimed to (i) describe coffee and tea intakes and (ii) assess their contribution to intakes of selected nutrients in adults across 10 European countries. Method: Between 1995 and 2000, a standardized 24-h dietary recall was conducted among 36,018 men and women from 27 European Prospective Investigation into Cancer and Nutrition (EPIC) study centres. Adjusted arithmetic means of intakes were estimated in grams (=volume) per day by sex and centre. Means of intake across centres were compared by sociodemographic characteristics and lifestyle factors. Results: In women, the mean daily intake of coffee ranged from 94 g/day (similar to 0.6 cups) in Greece to 781 g/day (similar to 4.4 cups) in Aarhus (Denmark), and tea from 14 g/day (similar to 0.1 cups) in Navarra (Spain) to 788 g/day (similar to 4.3 cups) in the UK general population. Similar geographical patterns for mean daily intakes of both coffee and tea were observed in men. Current smokers as compared with those who reported never smoking tended to drink on average up to 500 g/day more coffee and tea combined, but with substantial variation across centres. Other individuals' characteristics such as educational attainment or age were less predictive. In all centres, coffee and tea contributed to less than 10% of the energy intake. The greatest contribution to total sugar intakes was observed in Southern European centres (up to similar to 20%). Conclusion: Coffee and tea intake and their contribution to energy and sugar intake differed greatly among European adults. Variation in consumption was mostly driven by geographical region.
  •  
10.
  • Resch, Tim, et al. (författare)
  • The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study
  • 2000
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 20:2, s. 190-195
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: to study the proximal fixation of different aortic stent grafts in comparison to a hand-sewn anastomosis. DESIGN: experimental study. MATERIAL: the infrarenal aorta of 16 human cadavers were exposed, left in situ and transected 3 cm above the aortic bifurcation to mimic an infrarenal aortic neck. Stent grafts were deployed through a sheath 5 cm into the aorta. Ancure, Talent, Vanguard, Zenith and a Palmaz based stent graft were assessed. In addition a polyester graft was anastomosed to the aorta by running sutures. Distal force was applied to the grafts in increments of 0.5 Newton until the stent grafts were completely dislodged from the aorta. The displacement force (DF) was thereby determined. RESULTS: a force of 150 N (140-160) applied to the hand-sewn graft resulted in tearing of the aorta, without breakage of the sutures. The median displacement force was for Talent 4.5 N (1.3-5.5), Vanguard 9.0 N (3. 5-12), Ancure 12.5 N (12-14), Zenith 24 N (23-26.5) and Palmaz 25 N (17-25). Ballooning the stent after deployment improved fixation in some cases. CONCLUSIONS: a sutured anastomosis fixates a graft better than any stent design tested. Hooks and barbs improve the fixation of self-expandable stents. Balloon dilatation of the proximal stent after deployment might increase fixation further. Balloon expandable stents seem to provide good fixation without the use of hooks and barbs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 39
Typ av publikation
tidskriftsartikel (39)
Typ av innehåll
refereegranskat (39)
Författare/redaktör
Brunkwall, J (29)
Lindblad, Bengt (13)
Malina, Martin (12)
Ivancev, Krassi (12)
Brunkwall, Louise (7)
Risberg, B (6)
visa fler...
Orho-Melander, Marju (6)
Engström, Gunnar (5)
Lind, Lars (5)
Bergqvist, David (5)
Resch, Tim (5)
Ahmad, Shafqat (5)
Hammar, Ulf (5)
Sayols-Baixeras, Ser ... (5)
Baldanzi, Gabriel (5)
Ärnlöv, Johan, 1970- (4)
Smith, J Gustav (3)
Sundström, Johan, Pr ... (3)
Ericson, Ulrika (3)
Nguyen, Diem, PhD (3)
Fall, Tove, 1979- (3)
Nyman, Ulf (3)
Dekkers, Koen F. (3)
Bak Holm, Jacob (3)
Weiderpass, E (2)
Bergström, Göran, 19 ... (2)
Nilsson, Peter M (2)
Bergqvist, D (2)
Lindblad, B (2)
Nowak, Christoph (2)
Fall, Tove (2)
Sundström, Johan (2)
Dekkers, Koen (2)
Klinge, Björn (2)
Nguyen, Diem (2)
Fogelstrand, Per, 19 ... (2)
Lilja, B (2)
Freisling, H (2)
Larsson, Anna (2)
Smith, J. Gustav, 19 ... (2)
Boeckler, D. (2)
Larzon, Thomas (2)
Jönsson, Daniel (2)
Lin, Yi-Ting, 1981- (2)
Chirlaque, M-D (2)
Jensen, N (2)
Katzke, V (2)
Breuer, Silke (2)
Mattsson, Erney, 195 ... (2)
Kasprzak, P. (2)
visa färre...
Lärosäte
Lunds universitet (27)
Göteborgs universitet (8)
Uppsala universitet (8)
Karolinska Institutet (6)
Högskolan Dalarna (4)
Umeå universitet (3)
visa fler...
Örebro universitet (3)
Malmö universitet (1)
visa färre...
Språk
Engelska (39)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (33)
Naturvetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy