SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brunkwall Jan) "

Sökning: WFRF:(Brunkwall Jan)

  • Resultat 1-10 av 21
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Veith, Frank J., et al. (författare)
  • Collected world and single center experience with endovascular treatment of ruptured abdominal aortic aneurysms
  • 2009
  • Ingår i: Annals of Surgery. - 0003-4932 .- 1528-1140. ; 250:5, s. 818-824
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Case and single center reports have documented the feasibility and suggested the effectiveness of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs), but the role and value of such treatment remain controversial. OBJECTIVE: To clarify these we examined a collected experience with use of EVAR for RAAA treatment from 49 centers. METHODS: Data were obtained by questionnaires from these centers, updated from 13 centers committed to EVAR treatment whenever possible and included treatment details from a single center and information on 1037 patients treated by EVAR and 763 patients treated by open repair (OR). RESULTS: Overall 30-day mortality after EVAR in 1037 patients was 21.2%. Centers performing EVAR for RAAAs whenever possible did so in 28% to 79% (mean 49.1%) of their patients, had a 30-day mortality of 19.7% (range: 0%-32%) for 680 EVAR patients and 36.3% (range: 8%-53%) for 763 OR patients (P < 0.0001). Supraceliac aortic balloon control was obtained in 19.1% +/- 12.0% (+/-SD) of 680 EVAR patients. Abdominal compartment syndrome was treated by some form of decompression in 12.2% +/- 8.3% (+/-SD) of these EVAR patients. CONCLUSION: These results indicate that EVAR has a lower procedural mortality at 30 days than OR in at least some patients and that EVAR is better than OR for treating RAAA patients provided they have favorable anatomy; adequate skills, facilities, and protocols are available; and optimal strategies, techniques, and adjuncts are employed.
  •  
2.
  •  
3.
  • Brunkwall, Louise, et al. (författare)
  • The Malmö Offspring Study (MOS) : design, methods and first results.
  • 2021
  • Ingår i: European Journal of Epidemiology. - : Springer Nature. - 0393-2990 .- 1573-7284. ; 36, s. 103-116
  • Tidskriftsartikel (refereegranskat)abstract
    • As cardio metabolic disease manifestations tend to cluster in families there is a need to better understand the underlying mechanisms in order to further develop preventive strategies. In fact, genetic markers used in genetic risk scores, important as they are, will not be able alone to explain these family clusters. Therefore, the search goes on for the so called missing heritability to better explain these associations. Shared lifestyle and social conditions in families, but also early life influences may be of importance. Gene-environmental interactions should be explored. In recent years interest has grown for the role of diet-microbiota associations, as microbiota patterns may be shared by family members. In the Malmö Offspring Study that started in 2013, we have so far been able to examine about 4700 subjects (18-71 years) representing children and grandchildren of index subjects from the first generation, examined in the Malmö Diet Cancer Study during 1991 to 1996. This will provide rich data and opportunities to analyse family traits of chronic disease across three generations. We will provide extensive genotyping and phenotyping including cardiovascular and respiratory function, as well as markers of glucose metabolism. In addition, also cognitive function will be assessed. A 4-day online dietary recall will be conducted and gut as well as oral microbiota analysed. The ambition is to provide one of the first large-scale European family studies with individual data across three generations, which could deepen our knowledge about the role of family traits for chronic disease and its underlying mechanisms.
  •  
4.
  • Chuter, Timothy A M, et al. (författare)
  • A telescopic stent-graft for aortoiliac implantation
  • 1997
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 13:1, s. 79-84
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To test a new delivery system for a telescopic stent-graft. MATERIALS: Variable overlap between the components of this stent-graft combination allows length adjustment. This device differs from other multi-component stent-grafts in that both components are contained within a single delivery system. METHODS: The stent-graft was implanted in the distal thoracic to suprarenal aorta of five pigs (35-50 kg), where the arterial diameter falls by almost 50%. The proximal and distal components of the stent-graft were targeted to bony landmarks in the vertebral column. RESULTS: Inspection of completion angiograms showed both proximal and distal stent-grafts to be within 1 mm of their target locations in all five experiments. Overall combined stent-graft length varied from 13.5 cm to 16.1 cm depending on the location of the bony landmark chosen as the distal target, and on the size of the pig. CONCLUSIONS: This system may be useful for the repair of abdominal aortic aneurysm whenever preoperative sizing is difficult due to aortic tortuosity, or precluded due to the urgency of the procedure.
  •  
5.
  • Chuter, Timothy A M, et al. (författare)
  • Aneurysm pressure following endovascular exclusion
  • 1997
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 13:1, s. 85-87
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To assess the effect of stent-graft implantation on the pressure within an abdominal aortic aneurysm. METHODS: Aneurysm exclusion was performed using an aorto-uniiliac stent-graft in eight patients. Following stent-graft implantation, pressure measurements were performed through a catheter adjacent to the graft in the aneurysm. This "aneurysm pressure" was compared with radial arterial pressure. RESULTS: The pressure was lower in the aneurysm than in the radial artery, in all cases. Mean aneurysm pressure was 36.5/33.8 mmHg, while mean radial arterial pressure was 118.5/50.5 mmHg (p < 0.05, for both systolic and diastolic pressures). These findings corresponded with a reduction in the palpable abdominal pulse, and an absence of perigraft perfusion on follow-up computerised tomography. CONCLUSION: Stent-graft implantation produces a fall in the pressure within an abdominal aortic aneurysm.
  •  
6.
  •  
7.
  • Erlinge, David, et al. (författare)
  • Human neuropeptide Y Y1 receptor antisense oligodeoxynucleotide specifically inhibits neuropeptide Y-evoked vasoconstriction
  • 1993
  • Ingår i: European Journal of Pharmacology. - 1879-0712. ; 240:1, s. 77-80
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper describes a new approach for the development of an inhibitor of the contractile responses of neuropeptide Y in human blood vessels by the use of an antisense oligodeoxynucleotide complementary to human neuropeptide Y Y1 receptor mRNA. One micromolar of an antisense 18-base oligodeoxynucleotide (hY1-AS), corresponding to the human Y1 receptor NH2-terminus, was incubated with segments of human subcutaneous arteries and veins for 48 h at 37 degrees C. Control vessels were incubated with the corresponding sense oligodeoxynucleotide (hY1-S) or a 3-base mismatched antisense oligodeoxynucleotide (hY1-MM) or no oligodeoxynucleotide. The contractile response to neuropeptide Y was markedly attenuated in both arteries and veins after treatment with hY1-AS, but was unaffected by hY1-S or hY1-MM. The pD2 values, i.e. the potency of neuropeptide Y, did not differ in hY1-AS treated vessels, suggesting a non-competitive receptor interaction as a result of down-regulation of Y1 receptors. Responses to noradrenaline or high K+ were unaffected by hY1-AS. This study may represent a new and highly specific approach to vascular pharmacology.
  •  
8.
  • Erlinge, David, et al. (författare)
  • Neuropeptide Y stimulates proliferation of human vascular smooth muscle cells: cooperation with noradrenaline and ATP
  • 1994
  • Ingår i: Regulatory Peptides. - 1873-1686. ; 50:3, s. 259-265
  • Tidskriftsartikel (refereegranskat)abstract
    • Since the sympathetic nervous system has been shown to exert a trophic influence on vascular smooth muscle cells (SMC), we studied the growth regulating effects of neuropeptide Y (NPY) in cooperation with the sympathetic co-transmitters noradrenaline and adenosine triphosphate (ATP) in human vascular SMC. NPY stimulated DNA synthesis in human SMC grown from subcutaneous arteries and veins (diameter: 0.4 mm) measured by [3H]thymidine incorporation. Also cell number and protein synthesis were stimulated. The effect was mediated through the Y1-receptor and not Y2 or Y3 since the Y1-selective NPY analogue Pro34-NPY and peptide YY stimulated mitogenesis in the same magnitude as NPY while the NPY-fragment NPY13-36 only had minor effects. The effect was blocked by pretreating the cells with pertussis toxin indicating a Gi/o-coupled effect. The other sympathetic co-transmitters, noradrenaline and ATP, also stimulated mitogenesis in the human SMC in a similar magnitude as NPY. When added together NPY and noradrenaline potentiated each other in the mitogenic response. ATP had mainly additive effects. This is the first demonstration that NPY, noradrenaline and ATP stimulates growth in human vascular SMC. This suggests a role of the sympathetic cotransmitters in modulating vascular tone, but also by inducing hypertrophy/hyperplasia with possible clinical consequences.
  •  
9.
  • Ivancev, Krassi, et al. (författare)
  • Abdominal aortic aneurysms: experience with the Ivancev-Malmo endovascular system for aortomonoiliac stent-grafts
  • 1997
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 4:3, s. 242-251
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To describe a component-based aortomonoiliac stent-graft system and the first clinical results achieved with this device in endovascular abdominal aortic aneurysm (AAA) repair. METHODS: From November 1993 to October 1996, 45 patients aged 60 to 86 years underwent endoluminal exclusion of true AAAs (median diameter 60 mm) involving the common iliac arteries (median diameter 16 mm right and 15 mm left) using unilimb stent-grafts deployed with the Iancev-Malmo system. RESULTS: Six immediate conversions occurred in the beginning of the series due to endografts that were too short. Complications, including 2 inadvertent renal artery occlusions, 7 kinked grafts, 6 iliac artery dissections, and 3 perioccluder leaks, were prominent features in the first 15 patients. Five patients died in the postoperative period, four of whom were nonsurgical candidates. There were five significant stent-graft migrations: one 3 weeks after surgery due to mechanical injury of the proximal stent and four after 1 year owing to continuous dilation of a wide proximal neck, stent-graft placement in a conical, thrombus-lined proximal neck, and two instances of proximal extension separation from the main graft. Translumbar aneurysm perfusion required embolization in 3 patients. CONCLUSIONS: Despite early complications associated with a learning curve, exclusion of large AAAs using unilimb stent-grafts is feasible. Strict inclusion criteria are necessary in order to improve mortality among nonsurgical candidates and minimize the risk for late migration.
  •  
10.
  • Lind, Henrik, et al. (författare)
  • Selective increase of the contractile response to endothelin-1 in subcutaneous arteries from patients with essential hypertension
  • 1999
  • Ingår i: Blood Pressure. - : Informa UK Limited. - 0803-7051 .- 1651-1999. ; 8:1, s. 9-15
  • Tidskriftsartikel (refereegranskat)abstract
    • Endothelin-1 has been shown to contribute to basal vascular tone in man. Since endothelin-1 is a potent vasoconstrictor putatively involved in hypertension, we have compared the contractile responses of endothelin-1 and noradrenaline in relation to potassium chloride in subcutaneous resistance arteries from subjects with established essential hypertension with matched controls. Furthermore, with RT-PCR, the occurrence of mRNA for the ETA and ET(B) receptors was shown in the tunica media layer of subcutaneous arteries in controls and hypertensives. The maximum contractile response to endothelin-1 was significantly higher in the subcutaneous arteries of the hypertensives (by 88% with no change in potency) as compared to controls. The responses to noradrenaline, acetylcholine and potassium chloride did not differ between the groups. This selective increase in the contractile response to endothelin-1 might contribute to the development of essential hypertension.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 21

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy