SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Burmester Hilmar) "

Sökning: WFRF:(Burmester Hilmar)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bidola, Pidassa M., et al. (författare)
  • A high-speed X-ray Radiography Setup for in-situ Electron Beam Powder Bed Fusion at PETRA III
  • 2023
  • Ingår i: Advances in X-Ray/EUV Optics and Components XVIII. - : SPIE-Intl Soc Optical Eng.
  • Konferensbidrag (refereegranskat)abstract
    • A high-energy white synchrotron X-ray beam enables penetration of relatively thick and highly absorbing samples. At the P61A White Beam Engineering Materials Science Beamline, operated by Helmholtz-Zentrum Hereon at the PETRA III ring of the Deutsches Elektronen-Synchrotron (DESY), a tailored X-ray radiography system has been developed to perform in-situ X-ray imaging experiments at high temporal resolution, taking advantage of the unprecedented X-ray beam flux delivered by ten successive damping wigglers. The imaging system is equipped with an ultrahigh-speed camera (Phantom v2640) enabling acquisition rates up to 25 kHz at maximal resolution and binned mode. The camera is coupled with optical magnification (5x, 10x) and focusing lenses to enable imaging with a pixel size of 1,35 micrometre. The scintillator screens are housed in a special nitrogen gas cooling environment to withstand the heat load induced by the beam, allowing spatial resolution to be optimized down to few micrometres. We present the current state of the system development, implementation and first results of in situ investigations, especially of the electron beam powder bed fusion (PBF-EB) process, where the details of the mechanism of crack and pore formation during processing of different powder materials, e.g. steels and Ni-based alloys, is not yet known.
  •  
2.
  • Moosmann, Julian, et al. (författare)
  • A load frame for in situ tomography at PETRA III
  • 2019
  • Ingår i: Developments in X-Ray Tomography XII. - : SPIE. - 0277-786X .- 1996-756X. - 9781510629196 ; 11113
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • A load frame for in situ mechanical testing is developed for the microtomography end stations at the imaging beamline P05 and the high-energy material science beamline P07 of PETRA III at DESY, both operated by the Helmholtz- Zentrum Geesthacht. The load frame is fully integrated into the beamline control system and can be controlled via a feedback loop. All relevant parameters (load, displacement, temperature, etc.) are continuously logged. It can be operated in compression or tensile mode applying forces of up to 1 kN and is compatible with all contrast modalities available at IBL and HEMS i.e. conventional attenuation contrast, propagation based phase contrast and differential phase contrast using a grating interferometer. The modularity and flexibility of the load frame allows conducting a wide range of experiments. E.g. compression tests to understand the failure mechanisms in biodegradable implants in rat bone or to investigate the mechanics and kinematics of the tessellated cartilage skeleton of sharks and rays, or tensile tests to illuminate the structure-property relationship in poplar tension wood or to visualize the 3D deformation of the tendonbone insertion. We present recent results from the experiments described including machine-learning driven volume segmentation and digital volume correlation of load tomography sequences.
  •  
3.
  • Moosmann, Julian, et al. (författare)
  • Biodegradable magnesium-based implants in bone studied by synchrotron radiation microtomography
  • 2017
  • Ingår i: Developments in X-Ray Tomography XI. - : SPIE - International Society for Optical Engineering. ; 10391
  • Konferensbidrag (refereegranskat)abstract
    • Permanent implants made of titanium or its alloys are the gold standard in many orthopedic and traumatological applications due to their good biocompatibility and mechanical properties. However, a second surgical intervention is required for this kind of implants as they have to be removed in the case of children that are still growing or on patient's demand. Therefore, magnesium-based implants are considered for medical applications as they are degraded under physiological conditions. The major challenge is tailoring the degradation in a manner that is suitable for a biological environment and such that stabilization of the bone is provided for a controlled period. In order to understand failure mechanisms of magnesium-based implants in orthopedic applications and, further, to better understand the osseointegration, screw implants in bone are studied under mechanical load by means of a push-out device installed at the imaging beamline P05 of PETRA III at DESY. Conventional absorption contrast microtomography and phasecontrast techniques are applied in order to monitor the bone-to-implant interface under increasing load conditions. In this proof-of-concept study, first results from an in situ push-out experiment are presented.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy