SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Button T) "

Sökning: WFRF:(Button T)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Niemi, MEK, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
2.
  • Kanai, M, et al. (författare)
  • 2023
  • swepub:Mat__t
  •  
3.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
4.
  •  
5.
  •  
6.
  • Watt, F. E., et al. (författare)
  • Towards prevention of post-traumatic osteoarthritis : report from an international expert working group on considerations for the design and conduct of interventional studies following acute knee injury
  • 2019
  • Ingår i: Osteoarthritis and Cartilage. - : Elsevier BV. - 1063-4584. ; 27:1, s. 23-33
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: There are few guidelines for clinical trials of interventions for prevention of post-traumatic osteoarthritis (PTOA), reflecting challenges in this area. An international multi-disciplinary expert group including patients was convened to generate points to consider for the design and conduct of interventional studies following acute knee injury. Design: An evidence review on acute knee injury interventional studies to prevent PTOA was presented to the group, alongside overviews of challenges in this area, including potential targets, biomarkers and imaging. Working groups considered pre-identified key areas: eligibility criteria and outcomes, biomarkers, injury definition and intervention timing including multi-modality interventions. Consensus agreement within the group on points to consider was generated and is reported here after iterative review by all contributors. Results: The evidence review identified 37 studies. Study duration and outcomes varied widely and 70% examined surgical interventions. Considerations were grouped into three areas: justification of inclusion criteria including the classification of injury and participant age (as people over 35 may have pre-existing OA); careful consideration in the selection and timing of outcomes or biomarkers; definition of the intervention(s)/comparator(s) and the appropriate time-window for intervention (considerations may be particular to intervention type). Areas for further research included demonstrating the utility of patient-reported outcomes, biomarkers and imaging outcomes from ancillary/cohort studies in this area, and development of surrogate clinical trial endpoints that shorten the duration of clinical trials and are acceptable to regulatory agencies. Conclusions: These considerations represent the first international consensus on the conduct of interventional studies following acute knee joint trauma.
  •  
7.
  • Strand, Sven-Erik, et al. (författare)
  • Small animal imaging with pinhole single-photon emission computed tomography
  • 1994
  • Ingår i: Cancer. - 1097-0142. ; 73:Suppl. 3, s. 981-984
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND. High resolution spatial details of the distribution of activity in three dimensions is required to evaluate the localization and dosimetric properties of radiolabelled monoclonal antibodies in tumors and normal tissues. Planar imaging of small animals with a resolution of 5-10 mm is usually the imaging modality of choice. The authors investigated high resolution single-photon emission computed tomographic (SPECT) imaging, based on a rotating pinhole scintillation camera. Although the sensitivity of the pinhole collimator is low, several radionuclides offer suitable decay properties to perform pinhole SPECT, especially in conjunction with high activity levels used in radioimmunotherapy. METHODS. Transverse, sagittal, and coronal sections were reconstructed using a three-dimensional cone-beam algorithm, which is a generalization of the two-dimensional fan-beam filtered backprojection algorithm. Before reconstruction, the pinhole projections were corrected for the decay of the radionuclide, geometric and intrinsic efficiency variations of the camera system, and center of rotation shift. RESULTS. The spatial resolution at 50 mm from the pinhole collimator with 3.3 mm aperture was 3.4 mm, and the sensitivity 7.2 c/s microCi for technetium-99m. With the 2 mm collimator the resolution was 2.2 mm, and the sensitivity was 2.6 c/s/microCi. To show the spatial resolution in vivo, a rat was injected with 185 MBq of technetium-99m-methylene diphosphonate or with 5 mCi technetium-99m-hexamethylpropylene amine oxime. The bone structures were well delineated in the methylene diphosphonate image, and in the hexamethylpropylene amine oxime image, the brain was nicely shown. For comparison a magnetic resonance image for the same section was done. CONCLUSIONS. High resolution SPECT imaging with the pinhole collimator provides mapping of the activity in three-dimensions, needed for more detailed biodistribution data and to perform more accurate dosimetry.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy