SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cadamuro J.) "

Sökning: WFRF:(Cadamuro J.)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aad, G, et al. (författare)
  • 2015
  • swepub:Mat__t
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Weghuber, D., et al. (författare)
  • A 6-month randomized, double-blind, placebo-controlled trial of weekly exenatide in adolescents with obesity
  • 2020
  • Ingår i: Pediatric Obesity. - 2047-6302 .- 2047-6310. ; 15:7
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Pharmacological treatment options for adolescents with obesity are very limited. Glucagon-like-peptide-1 (GLP-1) receptor agonist could be a treatment option for adolescent obesity.OBJECTIVE: To investigate the effect of exenatide extended release on body mass index (BMI)-SDS as primary outcome, and glucose metabolism, cardiometabolic risk factors, liver steatosis, and other BMI metrics as secondary outcomes, and its safety and tolerability in adolescents with obesity.METHODS: Six-month, randomized, double-blinded, parallel, placebo-controlled clinical trial in patients (n = 44, 10-18 years, females n = 22) with BMI-SDS > 2.0 or age-adapted-BMI > 30 kg/m2 according to WHO were included. Patients received lifestyle intervention and were randomized to exenatide extended release 2 mg (n = 22) or placebo (n = 22) subcutaneous injections given once weekly. Oral glucose tolerance tests (OGTT) were conducted at the beginning and end of the intervention.RESULTS: Exenatide reduced (P < .05) BMI-SDS (-0.09; -0.18, 0.00), % BMI 95th percentile (-2.9%; -5.4, -0.3), weight (-3 kg; -5.8, -0.1), waist circumference (-3.2 cm; -5.8, -0.7), subcutaneous adipose tissue (-552 cm3 ; -989, -114), 2-hour-glucose during OGTT (-15.3 mg/dL; -27.5, -3.1), total cholesterol (11.6 mg/dL; -21.7, -1.5), and BMI (-0.83 kg/m2 ; -1.68, 0.01) without significant change in liver fat content (-1.36; -3.12, 0.4; P = .06) in comparison to placebo. Safety and tolerability profiles were comparable to placebo with the exception of mild adverse events being more frequent in exenatide-treated patients.CONCLUSIONS: Treatment of adolescents with severe obesity with extended-release exenatide is generally well tolerated and leads to a modest reduction in BMI metrics and improvement in glucose tolerance and cholesterol. The study indicates that the treatment provides additional beneficial effects beyond BMI reduction for the patient group.
  •  
6.
  •  
7.
  • Solomon, Cristina, et al. (författare)
  • Fibrinogen measurement in cardiac surgery with cardiopulmonary bypass: Analysis of repeatability and agreement of Clauss method within and between six different laboratories
  • 2014
  • Ingår i: Thrombosis and Haemostasis. - 0340-6245. ; 112:1, s. 109-117
  • Tidskriftsartikel (refereegranskat)abstract
    • Plasma fibrinogen concentration is important for coagulopathy assessment, and is most commonly measured using the Clauss method. Several factors, including device type and reagent, have been shown to affect results, The study objective was to evaluate performance and repeatability of the Clauss method and to assess differences between measurements performed during and after cardiopulmonary bypass (CPB), by testing plasma samples from patients undergoing cardiac surgery with CPB. Samples were collected from 30 patients before surgery, approximately 20 minutes before weaning from CPB, and 5 minutes after CPB and protamine. Fibrinogen concentration was determined using the Clauss method at six quality-controlled specialised laboratories, according to accredited standard operating procedures. Regarding within-centre agreement for Clauss measurement, mean differences between duplicate measurements were between 0.00 g/l and 0.15 g/l, with intervals for 95% limits of agreement for mean Bland-Altman differences up to 1.3 g/l. Regarding between-centre agreement, some mean differences between pairs of centres were above 0.5 g/l. Differences of up to similar to 2 g/l were observed with individual samples. Increased variability was observed between centres, with inter-class correlation values below 0.5 suggesting only fair agreement. There were no significant differences in fibrinogen concentration before weaning from CPB and after CPB for most centres and methods. In conclusion, considerable differences exist between Clauss-based plasma fibrinogen measured using different detection methods. Nevertheless, the similarity between measurements shortly before weaning from CPB and after CPB within centres suggests that on-pump measurements could provide an early estimation of fibrinogen deficit after CPB and thus guidance for haemostatic therapy.
  •  
8.
  •  
9.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy