SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Campi I) "

Sökning: WFRF:(Campi I)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Santoro, V., et al. (författare)
  • HighNESS conceptual design report: Volume I
  • 2024
  • Ingår i: Journal of Neutron Research. - 1023-8166 .- 1477-2655. ; 25:3-4, s. 85-314
  • Tidskriftsartikel (refereegranskat)abstract
    • The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world’s most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron source located below the spallation target. Compared to the first source, designed for high cold and thermal brightness, the new source has been optimized to deliver higher intensity, and a shift to longer wavelengths in the spectral regions of cold (CN, 2–20 Å), very cold (VCN, 10–120 Å), and ultracold (UCN, >500 Å) neutrons. The second source comprises a large liquid deuterium moderator designed to produce CN and support secondary VCN and UCN sources. Various options have been explored in the proposed designs, aiming for world-leading performance in neutronics. These designs will enable the development of several new instrument concepts and facilitate the implementation of a high-sensitivity neutron-antineutron oscillation experiment (NNBAR). This document serves as the Conceptual Design Report for the HighNESS project, representing its final deliverable.
  •  
2.
  • Santoro, V., et al. (författare)
  • HighNESS conceptual design report: Volume II. the NNBAR experiment.
  • 2024
  • Ingår i: Journal of Neutron Research. - 1023-8166 .- 1477-2655. ; 25:3-4, s. 315-406
  • Tidskriftsartikel (refereegranskat)abstract
    • A key aim of the HighNESS project for the European Spallation Source is to enable cutting-edge particle physics experiments. This volume presents a conceptual design report for the NNBAR experiment. NNBAR would exploit a new cold lower moderator to make the first search in over thirty years for free neutrons converting to anti-neutrons. The observation of such a baryon-number-violating signature would be of fundamental significance and tackle open questions in modern physics, including the origin of the matter-antimatter asymmetry. This report shows the design of the beamline, supermirror focusing system, magnetic and radiation shielding, and anti-neutron detector necessary for the experiment. A range of simulation programs are employed to quantify the performance of the experiment and show how background can be suppressed. For a search with full background suppression, a sensitivity improvement of three orders of magnitude is expected, as compared with the previous search. Civil engineering studies for the NNBAR beamline are also shown, as is a costing model for the experiment.
  •  
3.
  • Santoro, V., et al. (författare)
  • The HighNESS Project at the European Spallation Source : Current Status and Future Perspectives
  • 2024
  • Ingår i: Nuclear science and engineering. - 0029-5639 .- 1943-748X. ; 198:1, s. 31-63
  • Tidskriftsartikel (refereegranskat)abstract
    • The European Spallation Source (ESS), presently under construction in Lund, Sweden, is a multidisciplinary international laboratory that, once completed at full specifications, will operate the world's most powerful pulsed neutron source. Supported by a 3 M Euro Research and Innovation Action within the European Union Horizon 2020 program, a design study (HighNESS) is now underway to develop a second neutron source located below the spallation target. Compared to the first source, which is located above the spallation target and designed for high cold and thermal brightness, the new source is being optimized to deliver higher intensity and a shift to longer wavelengths in the spectral regions of cold neutrons (CNs) (2 to 20 & Aring;), very cold neutrons (VCNs) (10 to 120 & Aring;), and ultracold neutrons (UCNs) (> 500 & Aring;). The second source consists of a large liquid deuterium moderator to deliver CNs and serve secondary VCN and UCN sources, for which different options are under study. These new sources will boost several areas of condensed matter research and will provide unique opportunities in fundamental physics. The HighNESS project is now entering its last year, and we are working toward the Conceptual Design Report of the ESS upgrade. In this paper, results obtained in the first 2 years, ongoing developments, and future perspectives are described.
  •  
4.
  • Ferrannini, E., et al. (författare)
  • Mannose is an insulin-regulated metabolite reflecting whole-body insulin sensitivity in man
  • 2020
  • Ingår i: Metabolism: Clinical and Experimental. - : Elsevier BV. - 0026-0495. ; 102
  • Tidskriftsartikel (refereegranskat)abstract
    • Mannose is a glucose-associated serum metabolite mainly released by the liver. Recent studies have shown several unexpected pleiotropic effects of mannose including increased regulatory T cells (Tregs), prevention of auto-immune disease and ability to reduce growth of human cancer cells. We have previously shown in large cohorts that elevated serum mannose levels are associated with future development of type 2 diabetes (T2D) and cardiovascular disease. However, potential direct effects of mannose on insulin sensitivity in vivo or in vitro are unknown. We here show that administration of mannose (0.1 g/kg BW twice daily) for one week in man did not elicit negative effects on meal-modified glucose tolerance, markers of inflammation or insulin levels. Tregs number and insulin signaling in human liver cells were unchanged. These data suggest that mannose is a marker, and not a mediator, of insulin resistance. To verify this, we examined serum mannose levels during long-term euglycemic hyperinsulinemic clamps in non-diabetic and T2D individuals. Mannose was reduced by insulin infusion in proportion to whole-body insulin sensitivity. Thus, mannose is a biomarker of insulin resistance which may be useful for the early identification of diabetic individuals with insulin resistance and increased risk of its complications. © 2019 Elsevier Inc.
  •  
5.
  •  
6.
  •  
7.
  • Santoro, V., et al. (författare)
  • DEVELOPMENT OF A HIGH INTENSITY NEUTRON SOURCE AT THE EUROPEAN SPALLATION SOURCE : THE HIGHNESS PROJECT
  • 2022
  • Ingår i: Proceedings of the 14th International Topical Meeting on Nuclear Applications of Accelerators, AccApp 2021, Embedded with the 2021 ANS Winter Meeting. - 9780894487842 ; , s. 11-20
  • Konferensbidrag (refereegranskat)abstract
    • The European Spallation Source (ESS), presently under construction in Lund, Sweden, is a multidisciplinary international laboratory that will operate the world’s most powerful pulsed neutron source. Supported by a 3M Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) is now underway to develop a second neutron source below the spallation target. Compared to the first source, located above the spallation target and designed for high cold and thermal brightness, the new source will provide higher intensity, and a shift to longer wavelengths in the spectral regions of cold (2-20 Å), very cold (VCN, 10-120 Å), and ultra cold (UCN, > 500 Å) neutrons. The core of the second source will consist of a large liquid deuterium moderator to deliver a high flux of cold neutrons and to serve secondary VCN and UCN sources, for which different options are under study. The features of these new sources will boost several areas of condensed matter research and will provide unique opportunities in fundamental physics. Part of the HighNESS project is also dedicated to the development of future instruments that will make use of the new source and will complement the initial suite of instruments in construction at ESS. The HighNESS project started in October 2020. In this paper, the ongoing developments and the results obtained in the first year are described.
  •  
8.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy