SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cao Baiqiong) "

Sökning: WFRF:(Cao Baiqiong)

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Chang, Keke, et al. (författare)
  • Considerations on Circuit Design and Data Acquisition of a Portable Surface Plasmon Resonance Biosensing System
  • 2015
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 15:8, s. 20511-20523
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to develop a circuit for an inexpensive portable biosensing system based on surface plasmon resonance spectroscopy. This portable biosensing system designed for field use is characterized by a special structure which consists of a microfluidic cell incorporating a right angle prism functionalized with a biomolecular identification membrane, a laser line generator and a data acquisition circuit board. The data structure, data memory capacity and a line charge-coupled device (CCD) array with a driving circuit for collecting the photoelectric signals are intensively focused on and the high performance analog-to-digital (A/D) converter is comprehensively evaluated. The interface circuit and the photoelectric signal amplifier circuit are first studied to obtain the weak signals from the line CCD array in this experiment. Quantitative measurements for validating the sensitivity of the biosensing system were implemented using ethanol solutions of various concentrations indicated by volume fractions of 5%, 8%, 15%, 20%, 25%, and 30%, respectively, without a biomembrane immobilized on the surface of the SPR sensor. The experiments demonstrated that it is possible to detect a change in the refractive index of an ethanol solution with a sensitivity of 4.99838 × 10(5) ΔRU/RI in terms of the changes in delta response unit with refractive index using this SPR biosensing system, whereby the theoretical limit of detection of 3.3537 × 10(-5) refractive index unit (RIU) and a high linearity at the correlation coefficient of 0.98065. The results obtained from a series of tests confirmed the practicality of this cost-effective portable SPR biosensing system.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Li, Jianwei (1)
Liang, Hao (1)
Wang, Shun (1)
Chang, Keke (1)
Chen, Ruipeng (1)
Hu, Xinran (1)
visa fler...
Cao, Baiqiong (1)
Sun, Xiaohui (1)
Ma, Liuzheng (1)
Zhu, Juanhua (1)
Jiang, Min (1)
Hu, Jiandong (1)
visa färre...
Lärosäte
Högskolan i Gävle (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Teknik (1)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy