SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Capello R.) "

Sökning: WFRF:(Capello R.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Nijkamp, P., et al. (författare)
  • Towards a regional science academy : A manifesto
  • 2016
  • Ingår i: Region. - : European Regional Science Association. - 2409-5370. ; 3:1, s. R1-R16
  • Tidskriftsartikel (refereegranskat)abstract
    • This Manifesto provides a joint proposal to create a Regional Science Academy as a think-tank support platform for a strategic development of the spatial sciences. The Regional Science Academy is a strategic spatial knowledge catalyst: it acts as a global intellectual powerhouse for new knowledge network initiatives and scholarly views on regions and cities as vital centrepieces of interconnected spatial systems. This contribution highlights its role and presents various activity plans. 
  •  
3.
  • Kruse, N., et al. (författare)
  • Validation of a quantitative cerebrospinal fluid alpha-synuclein assay in a European-wide interlaboratory study
  • 2015
  • Ingår i: Neurobiology of Aging. - : Elsevier BV. - 0197-4580. ; 36:9, s. 2587-2596
  • Tidskriftsartikel (refereegranskat)abstract
    • Decreased levels of alpha-synuclein (aSyn) in cerebrospinal fluid (CSF) in Parkinson's disease and related synucleinopathies have been reported, however, not consistently in all cross-sectional studies. To test the performance of one recently released human-specific enzyme-linked immunosorbent assay (ELISA) for the quantification of aSyn in CSF, we carried out a round robin trial with 18 participating laboratories trained in CSF ELISA analyses within the BIOMARKAPD project in the EU Joint Program -Neurodegenerative Disease Research. CSF samples (homogeneous aliquots from pools) and ELISA kits (one lot) were provided centrally and data reported back to one laboratory for data analysis. Our study showed that although factors such as preanalytical sample handling and lot-to-lot variability were minimized by our study design, we identified high variation in absolute values of CSF aSyn even when the same samples and same lots of assays were applied. We further demonstrate that although absolute concentrations differ between laboratories the quantitative results are comparable. With further standardization this assay may become an attractive tool for comparing aSyn measurements in diverse settings. Recommendations for further validation experiments and improvement of the interlaboratory results obtained are given. (C) 2015 Elsevier Inc. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy