SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Carlhäll Carljohan 1973 ) "

Sökning: WFRF:(Carlhäll Carljohan 1973 )

  • Resultat 1-10 av 31
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lantz, Jonas, 1982-, et al. (författare)
  • Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations : Comparison with In Vivo 4D Flow MRI
  • 2019
  • Ingår i: Annals of Biomedical Engineering. - : Springer-Verlag New York. - 0090-6964 .- 1573-9686. ; 47:2, s. 413-424
  • Tidskriftsartikel (refereegranskat)abstract
    • Blood flow simulations are making their way into the clinic, and much attention is given to estimation of fractional flow reserve in coronary arteries. Intracardiac blood flow simulations also show promising results, and here the flow field is expected to depend on the pulmonary venous (PV) flow rates. In the absence of in vivo measurements, the distribution of the flow from the individual PVs is often unknown and typically assumed. Here, we performed intracardiac blood flow simulations based on time-resolved computed tomography on three patients, and investigated the effect of the distribution of PV flow rate on the flow field in the left atrium and ventricle. A design-of-experiment approach was used, where PV flow rates were varied in a systematic manner. In total 20 different simulations were performed per patient, and compared to in vivo 4D flow MRI measurements. Results were quantified by kinetic energy, mitral valve velocity profiles and root-mean-square errors of velocity. While large differences in atrial flow were found for varying PV inflow distributions, the effect on ventricular flow was negligible, due to a regularizing effect by mitral valve. Equal flow rate through all PVs most closely resembled in vivo measurements and is recommended in the absence of a priori knowledge.
  •  
2.
  • Bolger, Ann F, 1957-, et al. (författare)
  • Transit of blood flow through thehuman left ventricle mapped by cardiovascular magnetic resonance
  • 2007
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Informa UK Limited. - 1097-6647 .- 1532-429X. ; 9:5, s. 741-747
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:The transit of blood through the beating heart is a basic aspect of cardiovascular physiology which remains incompletely studied. Quantification of the components of multidirectional flow in the normal left ventricle (LV) is lacking, making it difficult to put the changes observed with LV dysfunction and cardiac surgery into context.METHODS:Three dimensional, three directional, time resolved magnetic resonance phase-contrast velocity mapping was performed at 1.5 Tesla in 17 normal subjects, 6 female, aged 44+/-14 years (mean+/-SD). We visualized and measured the relative volumes of LV flow components and the diastolic changes in inflowing kinetic energy (KE). Of total diastolic inflow volume, 44+/-11% followed a direct, albeit curved route to systolic ejection (videos 1 and 2), in contrast to 11% in a subject with mildly dilated cardiomyopathy (DCM), who was included for preliminary comparison (video 3). In normals, 16+/-8% of the KE of inflow was conserved to the end of diastole, compared with 5% in the DCM patient. Blood following the direct route lost or transferred less of its KE during diastole than blood that was retained until the next beat (1.6+/-1.0 millijoules vs 8.2+/-1.9 millijoules, p<0.05); whereas, in the DCM patient, the reduction in KE of retained inflow was 18-fold greater than that of the blood tracing the direct route.CONCLUSION:Multidimensional flow mapping can measure the paths, compartmentalization and kinetic energy changes of blood flowing into the LV, demonstrating differences of KE loss between compartments, and potentially between the flows in normal and dilated left ventricles.
  •  
3.
  • Carlhäll, Carljohan, 1973-, et al. (författare)
  • Contribution of mitral annular excursion and shape dynamics to total left ventricular volume change
  • 2004
  • Ingår i: American Journal of Physiology. Heart and Circulatory Physiology. - : American Physiological Society. - 0363-6135 .- 1522-1539. ; 287:4, s. H1836-H1841
  • Tidskriftsartikel (refereegranskat)abstract
    • The mitral annulus (MA) has a complex shape and motion, and its excursion has been correlated to left ventricular (LV) function. During the cardiac cycle the annulus’ excursion encompasses a volume that is part of the total LV volume change during both filling and emptying. Our objective was to evaluate the contribution of MA excursion and shape variation to total LV volume change. Nine healthy subjects aged 56 ± 11 (means ± SD) years underwent transesophageal echocardiography (TEE). The MA was outlined in all time frames, and a four-dimensional (4-D) Fourier series was fitted to the MA coordinates (3-D+time) and divided into segments. The annular excursion volume (AEV) was calculated based on the temporally integrated product of the segments’ area and their incremental excursion. The 3-D LV volumes were calculated by tracing the endocardial border in six coaxial planes. The AEV (10 ± 2 ml) represented 19 ± 3% of the total LV stroke volume (52 ± 12 ml). The AEV correlated strongly with LV stroke volume (r = 0.73; P < 0.05). Peak MA area occurred during middiastole, and 91 ± 7% of reduction in area from peak to minimum occurred before the onset of LV systole. The excursion of the MA accounts for an important portion of the total LV filling and emptying in humans. These data suggest an atriogenic influence on MA physiology and also a sphincter-like action of the MA that may facilitate ventricular filling and aid competent valve closure. This 4-D TEE method is the first to allow noninvasive measurement of AEV and may be used to investigate the impact of physiological and pathological conditions on this important aspect of LV performance.
  •  
4.
  •  
5.
  • Zajac, Jakub (författare)
  • Assessment of Ventricular Function in Normal and Failing Hearts Using 4D Flow CMR
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Heart failure is a common disorder and a major cause of illness and death in the population, creating an enormous health-care burden. It is a complex condition, representing the end-point of many cardiovascular diseases. In general heart failure progresses slowly over time and once it is diagnosed it has a poor prognosis which is comparable with that of many types of cancer.The heart has an ability to adapt in response to long lasting increases in hemodynamic demand; the heart conforms its shape and size in order to maintain adequate cardiac output. This process is called remodeling and can be triggered by pathologies such as hypertension or valvular disease. When the myocardial remodeling is maintained chronically it becomes maladaptive and is associated with an increased risk of heart failure.In many cases, heart failure is associated with left bundle branch block (LBBB). This electrical disturbance leads to dyssynchronous left ventricular (LV) contraction and relaxation which may contribute to cardiac dysfunction and ultimately heart failure. Mechanical dyssynchrony can be treated with cardiac resynchronization therapy (CRT). However, many heart failure patients do not demonstrate clinical improvement despite CRT.Blood flow plays an important role in the normal development of the fetal heart. However, flow-induced forces may also induce changes in the heart cells that could lead to pathological remodeling in the adult heart. Until recently, measurement tools have been inadequate in describing the complex three-dimensional and time-varying characteristics of blood flow within the beating heart.4D (3D + time) flow cardiovascular magnetic resonance (CMR) enables acquisition of three-dimensional, three-directional, time-resolved velocity data from which visualization and quantification of the blood flow patterns over a complete cardiac cycle can be performed. In this thesis, novel 4D Flow CMR based methods are used to study the intraventricular blood flow in healthy subjects and heart failure patients with and without ventricular dyssynchrony in order to gain new knowledge of the ventricular function.Different flow components were assessed in normal heart ventricles. It was found that inflowing blood that passes directly to outflow during the same heartbeat (the Direct Flow component) was larger and possessed more kinetic energy (KE) than other flow components. Diastolic flow through the normal heart appears to create favorable conditions for effective systolic ejection. This organized blood flow pattern within the normal LV is altered in heart failure patients and is associated with decreased preservation of KE which might be unfavorable for efficient LV ejection. Inefficient flow of blood through the heart may influence diastolic wall stress, and thus contribute to pathological myocardial remodeling.In dyssynchronous LVs of heart failure patients with LBBB, Direct Flow showed even more reduced preservation of KE compared to similarly remodeled LVs without LBBB. Furthermore, in LBBB patients, LV filling hemodynamic forces, acting on the myocardium, were more orthogonal to the main flow direction compared to patients without LBBB. Deviation of LV flow forces and reduction of KE preservation and may reflect impairment of LV diastolic function and less efficient ensuing ejection related to dyssynchrony in these failing ventricles.Blood flow patterns were also studied with respect to fluctuations of the velocity of the flow (turbulent flow) in normal and failing LVs. In failing hearts, turbulent kinetic energy (TKE) was higher during diastole than in healthy subjects. TKE is a cause of energy loss and can thus be seen as a measure of flow inefficiency.Elucidating the transit of multidimensional blood flow through the heart chambers is fundamental in understanding the physiology of the heart and to detect abnormalities in cardiac function. The 4D Flow CMR parameters presented in this thesis can be utilized to detect altered intracardiac blood flow and may be used as markers of deteriorating cardiac function, pathological remodeling and mechanical dyssynchrony in heart failure.
  •  
6.
  •  
7.
  • Bothe, Wolfgang, et al. (författare)
  • Effects of acute ischemic mitral regurgitation on three-dimensional mitral leaflet edge geometry
  • 2008
  • Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940 .- 1873-734X. ; 33, s. 191-197
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Improved quantitative understanding of in vivo leaflet geometry in ischemic mitral regurgitation (IMR) is needed to improve reparative techniques, yet few data are available due to current imaging limitations. Using marker technology we tested the hypotheses that IMR (1) occurs chiefly during early systole; (2) affects primarily the valve region contiguous with the myocardial ischemic insult; and (3) results in systolic leaflet edge restriction. Methods: Eleven sheep had radiopaque markers sutured as five opposing pairs along the anterior (A1–E1) and posterior (A2–E2) mitral leaflet free edges from the anterior commissure (A1–A2) to the posterior commissure (E1–E2). Immediately postoperatively, biplane videofluoroscopy was used to obtain 4D marker coordinates before and during acute proximal left circumflex artery occlusion. Regional mitral orifice area (MOA) was calculated in the anterior (Ant-MOA), middle (Mid-MOA), and posterior (Post-MOA) mitral orifice segments during early systole (EarlyS), mid systole (MidS), and end systole (EndS). MOA was normalized to zero (minimum orifice opening) at baseline EndS. Tenting height was the distance of the midpoint of paired markers to the mitral annular plane at EndS. Results: Acute ischemia increased echocardiographic MR grade (0.5 ± 0.3 vs 2.3 ± 0.7, p < 0.01) and MOA in all regions at EarlyS, MidS, and EndS: Ant-MOA (7 ± 10 vs 22 ± 19 mm2, 1 ± 2 vs18 ± 16 mm2, 0 vs 17 ± 15 mm2); Mid-MOA (9 ± 13 vs 25 ± 17 mm2, 3 ± 6 vs 21 ± 19 mm2, 0 vs 25 ± 17 mm2); and Post-MOA (8 ± 10 vs 25 ± 16, 2 ± 4 vs 22 ± 13 mm2, 0 vs 23 ± 13 mm2), all p < 0.05. There was no change in MOA throughout systole (EarlyS vs MidS vs EndS) during baseline conditions or ischemia. Tenting height increased with ischemia near the central and the anterior commissure leaflet edges (B1–B2: 7.1 ± 1.8 mm vs 7.9 ± 1.7 mm, C1–C2: 6.9 ± 1.3 mm vs 8.0 ± 1.5 mm, both p < 0.05). Conclusions: MOA during ischemia was larger throughout systole, indicating that acute IMR in this setting is a holosystolic phenomenon. Despite discrete postero-lateral myocardial ischemia, Post-MOA was not disproportionately larger. Acute ovine IMR was associated with leaflet restriction near the central and the anterior commissure leaflet edges. This entire constellation of annular, valvular, and subvalvular ischemic alterations should be considered in the approach to mitral repair for IMR.
  •  
8.
  •  
9.
  • Bustamante, Mariana, 1983- (författare)
  • Automated Assessment of Blood Flow in the Cardiovascular System Using 4D Flow MRI
  • 2018
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Medical image analysis focuses on the extraction of meaningful information from medical images in order to facilitate clinical assessment, diagnostics and treatment. Image processing techniques have gradually become an essential part of the modern health care system, a consequence of the continuous technological improvements and the availability of a variety of medical imaging techniques.Magnetic Resonance Imaging (MRI) is an imaging technique that stands out as non-invasive, highly versatile, and capable of generating high quality images without the use of ionizing radiation. MRI is frequently performed in the clinical setting to assess the morphology and function of the heart and vessels. When focusing on the cardiovascular system, blood flow visualization and quantification is essential in order to fully understand and identify related pathologies. Among the variety of MR techniques available for cardiac imaging, 4D Flow MRI allows for full three-dimensional spatial coverage over time, also including three-directional velocity information. It is a very powerful technique that can be used for retrospective analysis of blood flow dynamics at any location in the acquired volume.In the clinical routine, however, flow analysis is typically done using two-dimensional imaging methods. This can be explained by their shorter acquisition times, higher in-plane spatial resolution and signal-to-noise ratio, and their relatively simpler post-processing requirements when compared to 4D Flow MRI. The extraction of useful knowledge from 4D Flow MR data is especially challenging due to the large amount of information included in these images, and typically requires substantial user interaction.This thesis aims to develop and evaluate techniques that facilitate the post-processing of thoracic 4D Flow MRI by automating the steps necessary to obtain hemodynamic parameters of interest from the data. The proposed methods require little to no user interaction, are fairly quick, make effective use of the information available in the four-dimensional images, and can easily be applied to sizable groups of data.The addition of the proposed techniques to the current pipeline of 4D Flow MRI analysis simplifies and expedites the assessment of these images, thus bringing them closer to the clinical routine.
  •  
10.
  • Bustamante, Mariana, 1983-, et al. (författare)
  • Automated multi-atlas segmentation of cardiac 4D flow MRI
  • 2018
  • Ingår i: Medical Image Analysis. - : Elsevier. - 1361-8415 .- 1361-8423. ; 49, s. 128-140
  • Tidskriftsartikel (refereegranskat)abstract
    • Four-dimensional (4D) flow magnetic resonance imaging (4D Flow MRI) enables acquisition of time-resolved three-directional velocity data in the entire heart and all major thoracic vessels. The segmentation of these tissues is typically performed using semi-automatic methods. Some of which primarily rely on the velocity data and result in a segmentation of the vessels only during the systolic phases. Other methods, mostly applied on the heart, rely on separately acquired balanced Steady State Free Precession (b-SSFP) MR images, after which the segmentations are superimposed on the 4D Flow MRI. While b-SSFP images typically cover the whole cardiac cycle and have good contrast, they suffer from a number of problems, such as large slice thickness, limited coverage of the cardiac anatomy, and being prone to displacement errors caused by respiratory motion. To address these limitations we propose a multi-atlas segmentation method, which relies only on 4D Flow MRI data, to automatically generate four-dimensional segmentations that include the entire thoracic cardiovascular system present in these datasets. The approach was evaluated on 4D Flow MR datasets from a cohort of 27 healthy volunteers and 83 patients with mildly impaired systolic left-ventricular function. Comparison of manual and automatic segmentations of the cardiac chambers at end-systolic and end-diastolic timeframes showed agreements comparable to those previously reported for automatic segmentation methods of b-SSFP MR images. Furthermore, automatic segmentation of the entire thoracic cardiovascular system improves visualization of 4D Flow MRI and facilitates computation of hemodynamic parameters.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 31

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy