SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Carnstam Bo) "

Sökning: WFRF:(Carnstam Bo)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Granfeldt, Hans, et al. (författare)
  • The Linkoping-Lund surgical experience with the HeartMate left ventricular assist system
  • 1995
  • Ingår i: Annals of Thoracic Surgery. - 1552-6259. ; 59:Suppl. 1, s. 52-55
  • Tidskriftsartikel (refereegranskat)abstract
    • Four transplant candidates fulfilling the Food and Drug Administration criteria for a permanent left ventricular assist device received a pneumatic HeartMate system as a bridge to heart transplantation. All patients survived and were fully rehabilitated at the time of transplantation, which was carried out 2 to 6 months after the initial operation. There were no major complications associated with the procedures. We are impressed by the effectiveness and safety of the device.
  •  
2.
  •  
3.
  • Peterzén, Bengt, et al. (författare)
  • Anesthetic management of patients undergoing coronary artery bypass grafting with the use of an axial flow pump and a short-acting beta-blocker
  • 1999
  • Ingår i: Journal of cardiothoracic and vascular anesthesia. - 1053-0770. ; 13:4, s. 431-436
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: To describe the clinical protocol regarding monitoring, pharmacologic interventions, and postoperative care during and after coronary artery bypass grafting (CABG) on the beating heart with an axial flow pump and a short-acting β-blocker. Design: A retrospective study. Setting: A university hospital. Participants: Seventeen patients scheduled for elective CABG. Interventions: Invasive monitoring was performed with either a standard pulmonary artery catheter (PAC) or a surgically placed PAC. An axial flow pump was inserted through a graft sutured to the ascending aorta. A short-acting β-blocker was administered to decrease the motion of the heart and make conditions for CABG adequate and safe. Measurements and main results: Compared with baseline measurements, there were significant decreases in mean arterial blood pressure, mixed venous oxygen saturation, and right ventricular ejection fraction during maximal axial flow pump support and β-blockade. No significant change in heart rate was observed at this time. Hemodynamic variables were normalized in the intensive care unit. All patients were separated from the Hemopump without inotropic support, and values of troponin-T, aspartate aminotransferase, and alanine aminotransferase were low postoperatively. All patients survived and were discharged from the hospital. Conclusion: The anesthetic protocol for patients undergoing surgery with a beating heart and the combined use of an axial flow pump and a short-acting β-blocker is outlined. Multiple-vessel CABG on the beating heart was performed with maintenance of an acceptable hemodynamic situation.
  •  
4.
  • Peterzén, Bengt, et al. (författare)
  • Management of patients with end-stage heart disease treated with an implantable left ventricular assist device in a nontransplanting center
  • 2000
  • Ingår i: Journal of cardiothoracic and vascular anesthesia. - : Elsevier BV. - 1053-0770. ; 14:4, s. 438-443
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To describe the setup of a left ventricular assist device (LVAD) program in a nontransplanting center. Design: A prospective study from February 1993 to June 1999. Setting: A university hospital. Participants: Ten patients, 6 men, with a mean age of 44 years (range 16 to 63 years) and with end-stage heart failure resulting from dilated cardiomyopathy (n = 7) or ischemic heart disease (n = 3). Interventions: The patients received the TCI (Thermo Cardiosystems Inc, Woburn, MA) Heart Mate implantable assist device. Five patients had a pneumatic device, and 5 had an electric device. All except 1 patient with an electric device had the pump for an extended period. Measurements and Main Results: Median time on the ventilator was 6.2 days, and median time in the ICU was 14 days. Significant hemodynamic improvement was observed by echocardiography and invasive monitoring. Milrinone and epinephrine supplemented by prostaglandin E1 were the most commonly used drugs to avoid right-sided heart failure. Nine patients were transplanted after pump therapy of 241 days (median) (range, 56 to 873 days). One patient died because of endovascular infection and septicemia. Infectious complications were frequent, especially when the pump time was extended. Conclusions: The introduction of an LVAD program in a nontransplanting center can be achieved with good results. Intense collaboration with a transplant center is mandatory. The complication rate increased when treatment times were extended.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy