SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cinti S) "

Sökning: WFRF:(Cinti S)

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Burrascano, S., et al. (författare)
  • Where are we now with European forest multi-taxon biodiversity and where can we head to?
  • 2023
  • Ingår i: Biological Conservation. - 0006-3207. ; 284
  • Tidskriftsartikel (refereegranskat)abstract
    • The European biodiversity and forest strategies rely on forest sustainable management (SFM) to conserve forest biodiversity. However, current sustainability assessments hardly account for direct biodiversity indicators. We focused on forest multi-taxon biodiversity to: i) gather and map the existing information; ii) identify knowledge and research gaps; iii) discuss its research potential. We established a research network to fit data on species, standing trees, lying deadwood and sampling unit description from 34 local datasets across 3591 sampling units. A total of 8724 species were represented, with the share of common and rare species varying across taxonomic classes: some included many species with several rare ones (e.g., Insecta); others (e.g., Bryopsida) were repre-sented by few common species. Tree-related structural attributes were sampled in a subset of sampling units (2889; 2356; 2309 and 1388 respectively for diameter, height, deadwood and microhabitats). Overall, multi-taxon studies are biased towards mature forests and may underrepresent the species related to other develop-mental phases. European forest compositional categories were all represented, but beech forests were over-represented as compared to thermophilous and boreal forests. Most sampling units (94%) were referred to a habitat type of conservation concern. Existing information may support European conservation and SFM stra-tegies in: (i) methodological harmonization and coordinated monitoring; (ii) definition and testing of SFM in-dicators and thresholds; (iii) data-driven assessment of the effects of environmental and management drivers on multi-taxon forest biological and functional diversity, (iv) multi-scale forest monitoring integrating in-situ and remotely sensed information.
  •  
2.
  • Bostrom, P, et al. (författare)
  • Is irisin a human exercise gene? Reply
  • 2012
  • Ingår i: NATURE. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 488:7413, s. E10-E11
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
3.
  • Garibaldi, F., et al. (författare)
  • A PET scanner employing CsI films as photocathode
  • 2004
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 525:1-2, s. 263-267
  • Tidskriftsartikel (refereegranskat)abstract
    • Medical imaging is a fundamental tool in the diagnosis, treatments, and monitoring of disease processes as cancer. Detectors of large area and high Field Of View are necessary to scan the whole body in a reasonable time. Relatively large area photodetectors are necessary even for imaging of small mice and rats with high sensitivities and spatial resolutions, generally obtained by using pinhole or multipinhole collimators. Standard PET scanners, with scintillators coupled to photomultipliers, have generally a limited detector area due to the high costs of both scintillators and photomultipliers. In this respect, the replacement of photomultipliers with gaseous photodetectors represents a possible solution of the problem and brings the additional advantage to provide devices with sensitive areas free from dead regions. In this paper we report on a PET scanner equipped with a multiwire proportional chamber with a CsI thin film as photoconverter. A similar approach has already been successfully pursued in nuclear and particle physics experiments. A prototype of such a PET detector has been designed and built, and will be tested soon. Possible solutions for increasing the photoelectron number, and thus the detector performance, are presented.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Cancello, Raffaella, et al. (författare)
  • Reduction of macrophage infiltration and chemoattractant gene expression changes in white adipose tissue of morbidly obese subjects after surgery-induced weight loss.
  • 2005
  • Ingår i: Diabetes. - 0012-1797. ; 54:8, s. 2277-86
  • Tidskriftsartikel (refereegranskat)abstract
    • In human obesity, the stroma vascular fraction (SVF) of white adipose tissue (WAT) is enriched in macrophages. These cells may contribute to low-grade inflammation and to its metabolic complications. Little is known about the effect of weight loss on macrophages and genes involved in macrophage attraction. We examined subcutaneous WAT (scWAT) of 7 lean and 17 morbidly obese subjects before and 3 months after bypass surgery. Immunomorphological changes of the number of scWAT-infiltrating macrophages were evaluated, along with concomitant changes in expression of SVF-overexpressed genes. The number of scWAT-infiltrating macrophages before surgery was higher in obese than in lean subjects (HAM56+/CD68+; 22.6 +/- 4.3 vs. 1.4 +/- 0.6%, P < 0.001). Typical "crowns" of macrophages were observed around adipocytes. Drastic weight loss resulted in a significant decrease in macrophage number (-11.63 +/- 2.3%, P < 0.001), and remaining macrophages stained positive for the anti-inflammatory protein interleukin 10. Genes involved in macrophage attraction (monocyte chemotactic protein [MCP]-1, plasminogen activator urokinase receptor [PLAUR], and colony-stimulating factor [CSF]-3) and hypoxia (hypoxia-inducible factor-1alpha [HIF-1alpha]), expression of which increases in obesity and decreases after surgery, were predominantly expressed in the SVF. We show that improvement of the inflammatory profile after weight loss is related to a reduced number of macrophages in scWAT. MCP-1, PLAUR, CSF-3, and HIF-1alpha may play roles in the attraction of macrophages in scWAT.
  •  
8.
  • Cinti, M. N., et al. (författare)
  • Innovative LuYAP:Ce array for PET imaging
  • 2017
  • Ingår i: Journal of Instrumentation. - : Institute of Physics Publishing (IOPP). - 1748-0221. ; 12:3
  • Tidskriftsartikel (refereegranskat)abstract
    • We present an imaging characterization of a 10 x 10 LuYAP array (2 x 2 x 10 mm3 pixels) with an innovative dielectric coating insulation (0.015 mm thick), in view of its possible use in a gamma camera for imaging positron emission tomography (PET) or in similar applications, e.g. as γ-prompt detector in hadron therapy. The particular assembly of this array was realized in order to obtain a packing fraction of 98%, improving detection efficiency and light collection. For imaging purpose, the array has been coupled with a selected Hamamatsu H10966-100 Multi Anode Photomultiplier read out by a customized 64 independent channels electronics. This tube presents a superbialkali photocathode with 38% of quantum efficiency, permitting to enhance energy resolution and consequently image quality. A pixel identification of about 0.5 mm at 662 keV was obtained, highlighting the potentiality of this detector in PET applications.
  •  
9.
  • Pani, R., et al. (författare)
  • A study of response of a LuYAP : Ce array with innovative assembling for PET
  • 2015
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 795, s. 82-87
  • Tidskriftsartikel (refereegranskat)abstract
    • We propose the characterization of a first array of 10×10 Lutetium Yttrium Orthoaluminate Perovskite (LuYAP:Ce) crystals, 2 mm×2 mm×10 mm pixel size, with an innovative assembling designed to enhance light output, uniformity and detection efficiency. The innovation consists of the use of 0.015 mm thick dielectric coating as inter-pixel light-insulators, manufactured by Crytur (Czech Republic) intended to improve crystal insulation and then light collection. Respect to the traditional treatment with 0.2 mm of white epoxy, a thinner pixel gap enhances packing fraction up to 98% with a consequent improvement of detection efficiency. Spectroscopic characterization of the array was performed by a Hamamatsu R6231 photomultiplier tube. A pixel-by-pixel scanning with a collimated 99mTc radioisotope (140 keV photon energy) highlighted a deviation in pulse height close to 3.5% respect to the overall mean value. Meanwhile, in term of energy resolution a difference between the response of single pixel and the array of about 10% was measured. Results were also supported and validated by Monte Carlo simulations performed with GEANT4. Although the dielectric coating pixel insulator cannot overcome the inherent limitations of LuYAP crystal due to its self-absorption of light (still present), this study demonstrated that the new coating treatment allows better light collection (nearly close to the expected one) with in addition a very good uniformity between different pixels. These results confirm the high potentiality of this coating for any other crystal array suited for imaging application and new expectations for the use of LuYAP for PET systems.
  •  
10.
  • Pani, R., et al. (författare)
  • Investigation of radiation detection properties of CRY-018 and CRY-019 scintillators for medical imaging
  • 2016
  • Ingår i: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 11
  • Tidskriftsartikel (refereegranskat)abstract
    • During the last years the research for new scintillation crystals has been crucial for the improvement of imaging performance in nuclear medicine applications. Crytur company has recently released two new scintillators named CRY-018 and CRY-019 which are non hygroscopic, have short decay time and low refraction index. They represent the ideal candidates to substitute NaI:Tl and BGO crystals in future PET ad SPECT applications. The purpose of this work is to characterize this unknown crystals, look for possible applications in imaging for nuclear medicine. The results of this work were compared with the results obtained with a LaBr3:ce scintillation crystal. This particular crystal is used as a comparison benchmark because of its strong linear pulse height uniformity response and high energy resolution. Measurements have been performed with a high count rate which is typical for medical applications. Irradiation of the crystals have been performed in three different geometries and in a photon energy range suitable with SPECT and PET applications. The experimental results identify the CRY-018 as an Yttrium and Silicon mixture and the CRY-019 with as Lutetium and Silicon one. Moreover a light yield of about 45% of LaBr3 one, was obtained for both the CRY-018 and CRY-019. This is one of the higher light yield between most of the scintillation crystals usually used in nuclear medicine. Both crystals are characterized by a non-proportionality in the pulse height linearity response. Energy resolutions of 7.4% for CRY-018 and 8.4% for CRY-019 at 661 keV, have been measured. The intrinsic component of the energy resolution has been esteemed for all three scintillators. An intrinsic detection efficiency of about 45% at 122 keV for CRY-018 and 14% at 661 keV for CRY-019 has been measured. Compared with LaBr3:Ce efficiency, which is highly deteriorated by the coating required by the hygroscopicity, CRY-018 and CRY-019 are really interesting considering that these two samples are only 6 mm thick. Crytur's crystals seem to be suitable for nuclear medicine applications.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy