SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Collaud S.) "

Sökning: WFRF:(Collaud S.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Mueller, T., et al. (författare)
  • Characterization and intercomparison of aerosol absorption photometers : result of two intercomparison workshops
  • 2011
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 4:2, s. 245-268
  • Tidskriftsartikel (refereegranskat)abstract
    • Absorption photometers for real time application have been available since the 1980s, but the use of filter-based instruments to derive information on aerosol properties (absorption coefficient and black carbon, BC) is still a matter of debate. Several workshops have been conducted to investigate the performance of individual instruments over the intervening years. Two workshops with large sets of aerosol absorption photometers were conducted in 2005 and 2007. The data from these instruments were corrected using existing methods before further analysis. The inter-comparison shows a large variation between the responses to absorbing aerosol particles for different types of instruments. The unit to unit variability between instruments can be up to 30% for Particle Soot Absorption Photometers (PSAPs) and Aethalometers. Multi Angle Absorption Photometers (MAAPs) showed a variability of less than 5%. Reasons for the high variability were identified to be variations in sample flow and spot size. It was observed that different flow rates influence system performance with respect to response to absorption and instrumental noise. Measurements with non absorbing particles showed that the current corrections of a cross sensitivity to particle scattering are not sufficient. Remaining cross sensitivities were found to be a function of the total particle load on the filter. The large variation between the response to absorbing aerosol particles for different types of instruments indicates that current correction functions for absorption photometers are not adequate.
  •  
2.
  • Kersting, J., et al. (författare)
  • Effect of Radiotherapy Dose on Outcome in Nonmetastatic Sarcoma
  • 2023
  • Ingår i: Advances in Radiation Oncology. - 2452-1094. ; 8:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Radiation therapy (RT) is an integral part of Ewing sarcoma (EwS) therapy. The Ewing 2008 protocol recommended RT doses ranging from 45 to 54 Gy. However, some patients received other doses of RT. We analyzed the effect of different RT doses on event-free survival (EFS) and overall survival (OS) in patients with EwS.Methods and Materials: The Ewing 2008 database included 528 RT-admitted patients with nonmetastatic EwS. Recommended multimodal therapy consisted of multiagent chemotherapy and local treatment consisting of surgery (S & RT group) and/or RT (RT group). EFS and OS were analyzed with uni-and multivariable Cox regression models including known prognostic factors such as age, sex, tumor volume, surgical margins, and histologic response.Results: S & RT was performed in 332 patients (62.9%), and 145 patients (27.5%) received definitive RT. Standard dose =53 Gy (d1) was admitted in 57.8%, high dose of 54 to 58 Gy (d2) in 35.5%, and very high dose > 59 Gy (d3) in 6.6% of patients. In the RT group, RT dose was d1 in 11.7%, d2 in 44.1%, and d3 in 44.1% of patients. Three-year EFS in the S & RT group was 76.6% for d1, 73.7% for d2, and 68.2% for d3 (P = .42) and in the RT group 52.9%, 62.5%, and 70.3% (P = .63), respectively. Multivariable Cox regression revealed age > 15 years (hazard ratio [HR], 2.68; 95% confidence interval [CI], 1.63-4.38) and nonradical margins (HR, 1.76; 95% CI, 1.05-2.93) for the S & RT group (sex, P = .96; histologic response, P = .07; tumor volume, P = .50; dose, P = .10) and large tumor volume (HR, 2.20; 95% CI, 1.21-4.0) for the RT group as independent factors (dose, P = .15; age, P = .08; sex, P = .40).Conclusions: In the combined local therapy modality group, treatment with higher RT dose had an effect on EFS, whereas higher dose of radiation when treated with definitive RT was associated with an increased OS. Indications for selection biases for dosage were found. Upcoming trials will assess the value of different RT doses in a randomized manner to control for potential selection bias.
  •  
3.
  • Asmi, A., et al. (författare)
  • Aerosol decadal trends - Part 2: In-situ aerosol particle number concentrations at GAW and ACTRIS stations
  • 2013
  • Ingår i: Atmospheric Chemistry and Physics. - : Copernicus GmbH. - 1680-7324. ; 13:2, s. 895-916
  • Tidskriftsartikel (refereegranskat)abstract
    • We have analysed the trends of total aerosol particle number concentrations (N) measured at long-term measurement stations involved either in the Global Atmosphere Watch (GAW) and/or EU infrastructure project ACTRIS. The sites are located in Europe, North America, Antarctica, and on Pacific Ocean islands. The majority of the sites showed clear decreasing trends both in the full-length time series, and in the intra-site comparison period of 2001-2010, especially during the winter months. Several potential driving processes for the observed trends were studied, and even though there are some similarities between N trends and air temperature changes, the most likely cause of many northern hemisphere trends was found to be decreases in the anthropogenic emissions of primary particles, SO2 or some co-emitted species. We could not find a consistent agreement between the trends of N and particle optical properties in the few stations with long time series of all of these properties. The trends of N and the proxies for cloud condensation nuclei (CCN) were generally consistent in the few European stations where the measurements were available. This work provides a useful comparison analysis for modelling studies of trends in aerosol number concentrations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy