SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cox Maurice) "

Sökning: WFRF:(Cox Maurice)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bich, Walter, et al. (författare)
  • Revision of the 'Guide to the Expression of Uncertainty in Measurement'
  • 2012
  • Ingår i: Metrologia. - : IOP Publishing. - 0026-1394 .- 1681-7575. ; 49:6, s. 702-705
  • Tidskriftsartikel (refereegranskat)abstract
    • The Joint Committee for Guides in Metrology, Working Group 1, JCGM-WG1, is currently revising the 'Guide to the Expression of Uncertainty in Measurement'. In this communication, the motivation for undertaking such a revision is given and the main changes with respect to the current, 2008 edition are outlined.
  •  
2.
  • Gear, Jonathan I., et al. (författare)
  • EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations
  • 2018
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 45:13, s. 2456-2474
  • Tidskriftsartikel (refereegranskat)abstract
    • A framework is proposed for modelling the uncertainty in the measurement processes constituting the dosimetry chain that are involved in internal absorbed dose calculations. The starting point is the basic model for absorbed dose in a site of interest as the product of the cumulated activity and a dose factor. In turn, the cumulated activity is given by the area under a time–activity curve derived from a time sequence of activity values. Each activity value is obtained in terms of a count rate, a calibration factor and a recovery coefficient (a correction for partial volume effects). The method to determine the recovery coefficient and the dose factor, both of which are dependent on the size of the volume of interest (VOI), are described. Consideration is given to propagating estimates of the quantities concerned and their associated uncertainties through the dosimetry chain to obtain an estimate of mean absorbed dose in the VOI and its associated uncertainty. This approach is demonstrated in a clinical example.
  •  
3.
  • Gustafsson, Johan Ruben, et al. (författare)
  • Uncertainty propagation for SPECT/CT-based renal dosimetry in (177)Lu peptide receptor radionuclide therapy.
  • 2015
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 60:21, s. 8329-8346
  • Tidskriftsartikel (refereegranskat)abstract
    • A computer model of a patient-specific clinical (177)Lu-DOTATATE therapy dosimetry system is constructed and used for investigating the variability of renal absorbed dose and biologically effective dose (BED) estimates. As patient models, three anthropomorphic computer phantoms coupled to a pharmacokinetic model of (177)Lu-DOTATATE are used. Aspects included in the dosimetry-process model are the gamma-camera calibration via measurement of the system sensitivity, selection of imaging time points, generation of mass-density maps from CT, SPECT imaging, volume-of-interest delineation, calculation of absorbed-dose rate via a combination of local energy deposition for electrons and Monte Carlo simulations of photons, curve fitting and integration to absorbed dose and BED. By introducing variabilities in these steps the combined uncertainty in the output quantity is determined. The importance of different sources of uncertainty is assessed by observing the decrease in standard deviation when removing a particular source. The obtained absorbed dose and BED standard deviations are approximately 6% and slightly higher if considering the root mean square error. The most important sources of variability are the compensation for partial volume effects via a recovery coefficient and the gamma-camera calibration via the system sensitivity.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy