SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cranmer JN) "

Sökning: WFRF:(Cranmer JN)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
5.
  • Whaley, B, et al. (författare)
  • Using clinical cascades to measure health facilities' obstetric emergency readiness: testing the cascade model using cross-sectional facility data in East Africa
  • 2022
  • Ingår i: BMJ open. - : BMJ. - 2044-6055. ; 12:4, s. e057954-
  • Tidskriftsartikel (refereegranskat)abstract
    • Globally, hundreds of women die daily from preventable pregnancy-related causes, with the greatest burden in sub-Saharan Africa. Five key emergencies—bleeding, infections, high blood pressure, delivery complications and unsafe abortions—account for nearly 75% of these obstetric deaths. Skilled clinicians with strategic supplies could prevent most deaths. In this study, we (1) measured facility readiness to manage common obstetric emergencies using the clinical cascades and signal function tracers; (2) compared these readiness estimates by facility characteristics; and (3) measured cascading drop-offs in resources.DesignA facility-based cross-sectional analysis of resources for common obstetric emergencies.SettingData were collected in 2016 from 23 hospitals (10 designated comprehensive emergency obstetric care (CEmOC) facilities) in Migori County, western Kenya, and Busoga Region, eastern Uganda, in the Preterm Birth Initiative study in East Africa. Baseline data were used to estimate a facility’s readiness to manage common obstetric emergencies using signal function tracers and the clinical cascade model. We compared emergency readiness using the proportion of facilities with tracers (signal functions) and the proportion with resources for identifying and treating the emergency (cascade stages 1 and 2).ResultsThe signal functions overestimated practical emergency readiness by 23 percentage points across five emergencies. Only 42% of CEmOC-designated facilities could perform basic emergency obstetric care. Across the three stages of care (identify, treat and monitor-modify) for five emergencies, there was a 28% pooled mean drop-off in readiness. Across emergencies, the largest drop-off occurred in the treatment stage. Patterns of drop-off remained largely consistent across facility characteristics.ConclusionsAccurate measurement of obstetric emergency readiness is a prerequisite for strengthening facilities’ capacity to manage common emergencies. The cascades offer stepwise, emergency-specific readiness estimates designed to guide targeted maternal survival policies and programmes.Trial registration numberNCT03112018.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy