SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cranshaw Jules) "

Sökning: WFRF:(Cranshaw Jules)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Glover, Guy W., et al. (författare)
  • Intravascular versus surface cooling for targeted temperature management after out-of-hospital cardiac arrest - an analysis of the TTM trial data
  • 2016
  • Ingår i: Critical Care. - : Springer Science and Business Media LLC. - 1364-8535. ; 20:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Targeted temperature management is recommended after out-of-hospital cardiac arrest and may be achieved using a variety of cooling devices. This study was conducted to explore the performance and outcomes for intravascular versus surface devices for targeted temperature management after out-of-hospital cardiac arrest. Method: A retrospective analysis of data from the Targeted Temperature Management trial. N=934. A total of 240 patients (26%) managed with intravascular versus 694 (74%) with surface devices. Devices were assessed for speed and precision during the induction, maintenance and rewarming phases in addition to adverse events. All-cause mortality, as well as a composite of poor neurological function or death, as evaluated by the Cerebral Performance Category and modified Rankin scale were analysed. Results: For patients managed at 33°C there was no difference between intravascular and surface groups in the median time taken to achieve target temperature (210 [interquartile range (IQR) 180] minutes vs. 240 [IQR 180] minutes, p=0.58), maximum rate of cooling (1.0 [0.7] vs. 1.0 [0.9] °C/hr, p=0.44), the number of patients who reached target temperature (within 4hours (65% vs. 60%, p=0.30); or ever (100% vs. 97%, p=0.47), or episodes of overcooling (8% vs. 34%, p=0.15). In the maintenance phase, cumulative temperature deviation (median 3.2 [IQR 5.0] °C hr vs. 9.3 [IQR 8.0] °C hr, p=<0.001), number of patients ever out of range (57.0% vs. 91.5%, p=0.006) and median time out of range (1 [IQR 4.0] hours vs. 8.0 [IQR 9.0] hours, p=<0.001) were all significantly greater in the surface group although there was no difference in the occurrence of pyrexia. Adverse events were not different between intravascular and surface groups. There was no statistically significant difference in mortality (intravascular 46.3% vs. surface 50.0%; p=0.32), Cerebral Performance Category scale 3-5 (49.0% vs. 54.3%; p=0.18) or modified Rankin scale 4-6 (49.0% vs. 53.0%; p=0.48). Conclusions: Intravascular and surface cooling was equally effective during induction of mild hypothermia. However, surface cooling was associated with less precision during the maintenance phase. There was no difference in adverse events, mortality or poor neurological outcomes between patients treated with intravascular and surface cooling devices. Trial registration: TTM trial ClinicalTrials.gov number https://clinicaltrials.gov/ct2/show/NCT01020916 NCT01020916; 25 November 2009
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy