SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Crater S. W.) "

Sökning: WFRF:(Crater S. W.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Nelwan, S. P., et al. (författare)
  • Assessment of derived 12-lead electrocardiograms using general and patient-specific reconstruction strategies at rest and during transient myocardial ischemia
  • 2004
  • Ingår i: Am J Cardiol. - 0002-9149. ; 94:12, s. 1529-33
  • Tidskriftsartikel (refereegranskat)abstract
    • Twelve-lead ST-segment monitoring is a widely used tool for capturing focal ischemia and transient intermittent episodes. However, continuous registration of all 10 electrodes is impractical in clinical settings. This study investigated the accuracy of 2 derived 12-lead strategies that required 6 electrodes, including all limb leads, and 2 precordial leads by using population-based (generalized) and individualized (patient-specific) reconstruction coefficients to derive the additional 4 chest leads. A total of 26,880 simultaneous digital conventional 12-lead generalized and patient-specific electrocardiograms were monitored over 112 hours in 39 patients during percutaneous coronary intervention, including 159 balloon occlusions in 63 arteries, to test accuracy at rest and during ischemia. Occlusion duration was 78 seconds (range 42 to 96) in the left main coronary in 2 patients, the left anterior descending artery in 15, the right coronary artery in 10, the circumflex artery in 2, and graft segments in 5 patients. Average summated 12-lead ST deviation over the study population at baseline was 377 microV (range 104 to 1,718), which increased at peak ischemia to an average of 1,086 microV (range 282 to 4,099). Median absolute differences at peak ischemic ST deviation were 25 microV in lead V(1), 0 microV in lead V(2), 35 microV in lead V(3), 34 microV in lead V(4), 0 microV in lead V(5), 11 microV in lead V(6), and 114 microV for summated 12-lead ST deviation with the generalized method and 7 microV in lead V(1), 4 microV in lead V(2), 1 muV in lead V(3), 5 microV in lead V(4), 4 microV in lead V(5), 9 microV in lead V(6), and 83 microV for the summated 12-lead ST deviation with the patient-specific method. Limb leads (I, II, III, aVR, aVL, and aVF) were identical in all patients. Thus, generalized and patient-specific methods derived from 12-lead electrocardiography using actual limb and 2 precordial electrodes accurately derived the additional chest leads at rest and during ischemia. These approaches appear to be more practical than conventional 10-electrode monitoring but preserve high accuracy.
  •  
3.
  • Rebeiz, A. G., et al. (författare)
  • Comparison of ST-segment resolution with combined fibrinolytic and glycoprotein IIb/IIIa inhibitor therapy versus fibrinolytic alone (data from four clinical trials)
  • 2005
  • Ingår i: Am J Cardiol. - 0002-9149. ; 95:5, s. 611-4
  • Tidskriftsartikel (refereegranskat)abstract
    • We compared combination fibrinolytic plus glycoprotein IIb/IIIa inhibitor therapy with stand-alone fibrinolysis with respect to speed and stability of reperfusion in patients who had acute ST-segment elevation myocardial infarction; data were obtained from 654 patients in 4 trials (Integrilin to Manage Platelet Aggregation to Combat Thrombosis in Acute Myocardial Infarction, Platelet Aggregation Receptor Antagonist Dose Investigation and Reperfusion Gain in Myocardial Infarction, Integrilin and Tenecteplase in Acute Myocardial Infarction, and the Fifth Global Use of Strategies to Open Occluded Coronary Arteries) that compared thrombolytics plus lamifiban, eptifibatide, or abciximab with standard thrombolysis. We found significantly faster and more stable ST-segment recovery with combination therapy starting at 60 minutes (56.7% vs 48.0% with >/=50% ST-segment resolution, p = 0.03) and sustained over 180 minutes after drug administration; this transient benefit may suggest a time frame when more optimal percutaneous coronary intervention can be performed.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy