SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Denison F C) "

Sökning: WFRF:(Denison F C)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Doriese, W B, et al. (författare)
  • A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science
  • 2017
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 88:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.
  •  
2.
  • Rahnev, D, et al. (författare)
  • The Confidence Database
  • 2020
  • Ingår i: Nature human behaviour. - : Springer Science and Business Media LLC. - 2397-3374. ; 4:3, s. 317-325
  • Tidskriftsartikel (refereegranskat)
  •  
3.
  • Robb, A O, et al. (författare)
  • Influence of menstrual cycle on circulating endothelial progenitor cells
  • 2009
  • Ingår i: Human Reproduction. - Oxford, England : Oxford University Press (OUP). - 0268-1161 .- 1460-2350. ; 24:3, s. 619-625
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Endothelial progenitor cells (EPCs) are circulating mononuclear cells that participate in angiogenesis. The aim of this study was to determine the influence of the menstrual cycle on the number and function of EPCs, and to investigate their relationship with circulating concentrations of sex steroids and inflammatory mediators. METHODS: Ten healthy nulliparous, premenopausal, non-smoking women with regular menses were studied over a single menstrual cycle. Venepuncture was performed in the menstrual, follicular, peri-ovulatory and luteal phases. EPCs were quantified by flow cytometry (CD133(+)CD34(+)KDR(+) phenotype) and the colony-forming unit (CFU-EPC) functional assay. Circulating concentrations of estradiol, progesterone and inflammatory mediators (TNF-alpha, IL-6, sICAM-1 and VEGF) were measured by immunoassays. RESULTS: The numbers of CD133(+)CD34(+)KDR(+) cells were higher in the follicular phase (0.99 +/- 0.3 x 10(6) cells/l) compared with the peri-ovulatory phase (0.29 +/- 0.1 x 10(6) cells/l; P < 0.05). In contrast, the numbers of CFU-EPCs did not vary over the menstrual cycle. There were no correlations between EPCs and concentrations of either circulating sex steroids or inflammatory mediators. CONCLUSIONS: CD133(+)CD34(+)KDR(+) cells but not CFU-EPCs vary during the menstrual cycle. Our findings suggest a potential role for circulating EPCs in the normal cycle of physiological angiogenesis and repair of the uterine endometrium that is independent of circulating sex steroids or inflammatory mediators.
  •  
4.
  • Robb, A O, et al. (författare)
  • The influence of the menstrual cycle, normal pregnancy and pre-eclampsia on platelet activation
  • 2010
  • Ingår i: Thrombosis and Haemostasis. - 0340-6245 .- 2567-689X. ; 103:2, s. 372-378
  • Tidskriftsartikel (refereegranskat)abstract
    • Platelet activation has a key role in mediating thrombotic and inflammatory events. This study aimed to determine the influence of the menstrual cycle, pregnancy and pre-eclampsia on in vivo platelet activation. Twelve healthy nulliparous, non-smoking women with regular menses were studied over a single menstrual cycle. Twenty-one healthy primigravida pregnant women were studied longitudinally at 16, 24, 32 and 37 weeks gestation and seven weeks post-partum. Sixteen primigravida women with pre-eclampsia were studied at time of diagnosis and at seven weeks post-partum. Platelet-monocyte aggregates and platelet-surface P-selectin expression were assessed by flow-cytometry. Soluble P-selectin and CD40 ligand (CD40L) were measured by ELISA. Markers of platelet activation did not vary over the menstrual cycle. Platelet-monocyte aggregates were greater in the third trimester of pregnancy compared to non-pregnant women (p=0.003). Platelet surface and plasma soluble P-selectin concentrations increased with gestation (p<0.0001) and were raised by 24 weeks of pregnancy compared to non-pregnant women (p< or =0.02 for both) and together with platelet monocyte aggregates, decreased post-partum (p< or =0.02). Soluble CD40L concentrations fell in pregnancy, reaching a nadir at mid-gestation (p=0.002). There were no differences in markers of platelet activation between normal and pre-eclamptic pregnancies. In conclusion, platelet activation is increased in pregnancy and increases with gestation but is unaffected by pre-eclampsia. This suggests that systemic platelet activation is a feature of pregnancy but this is not affected by established pre-eclampsia.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy