SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Doekes G) "

Sökning: WFRF:(Doekes G)

  • Resultat 1-10 av 24
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gehring, U, et al. (författare)
  • Asthma and allergic symptoms in relation to house dust endotoxin : Phase Two of the International Study on Asthma and Allergies in Childhood (ISAAC II)
  • 2008
  • Ingår i: Clinical and Experimental Allergy. - : Wiley. - 0954-7894 .- 1365-2222. ; 38:12, s. 1911-1920
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Several studies have consistently reported inverse associations between exposure to endotoxin in house dust and atopy. With regard to the association between house dust endotoxin and asthma, the results are inconsistent. Objectives: To study the association between house dust endotoxin levels and respiratory symptoms and atopy in populations from largely different countries. Methods: Data were collected within the International Study on Asthma and Allergies in Childhood Phase Two, a multi-centre cross-sectional study of 840 children aged 9-12 years from six centres in the five countries of Albania, Italy, New Zealand, Sweden and the United Kingdom. Living room floor dust was collected and analysed for endotoxin. Health end-points and demographics were assessed by standardized questionnaires. Atopy was assessed by measurements of allergen-specific IgE against a panel of inhalant allergens. Associations between house dust endotoxin and health outcomes were analysed by logistic regression. Odds ratios (ORs) were presented for an overall interquartile range increase in exposure. Results: Many associations between house dust endotoxin in living room floor dust and health outcomes varied between countries. Combined across countries, endotoxin levels were inversely associated with asthma ever [adjusted OR (95% confidence interval (CI)) 0.53 (0.29-0.96) for endotoxin levels per m(2) of living room floor] and current wheeze [adjusted OR (95% CI) 0.77 (0.64-0.93) for endotoxin levels per gram of living room floor dust]. There were inverse associations between endotoxin concentrations and atopy, which were statistically significant in unadjusted analyses, but not after adjustment for gender, parental allergies, cat and house dust mite allergens. No associations were found with dust quantity and between endotoxin exposure and hayfever. Conclusion: These findings suggest an inverse association between endotoxin levels in living room floor dust and asthma in children.
  •  
2.
  •  
3.
  •  
4.
  • Bakolis, I, et al. (författare)
  • Respiratory health and endotoxin : associations and modification by CD14/-260 genotype
  • 2012
  • Ingår i: European Respiratory Journal. - : European Respiratory Society (ERS). - 0903-1936 .- 1399-3003. ; 39:3, s. 573-581
  • Tidskriftsartikel (refereegranskat)abstract
    • Exposure to endotoxin has been associated with increased respiratory symptoms and decrements in lung function in occupational settings but little is known about health effects of domestic exposure in adults. We describe the association of respiratory disease, IgE sensitisation, bronchial reactivity and lung function with mattress endotoxin levels in adults and determine whether these associations are modified by polymorphisms in CD14.Endotoxin levels in mattress dust from a population based sample of 972 adults were measured. Associations were examined using generalized linear mixed models, adjusting for individual and household confounders. Effect modification of these associations by CD14/-260 (rs2569190) was assessed.Mattress endotoxin levels varied from 0.1 to 402.6 EU·mg(-1). Although there was no overall association of lung function with endotoxin exposure, there was evidence that the association of FEV1 and FVC with endotoxin was modified by CD14/-260 genotype (p for interaction 0.005 and 0.013 respectively). There was no evidence that symptoms, IgE sensitisation or bronchial reactivity was associated with mattress endotoxin levels.In this large epidemiological study of adults there was no evidence that mattress endotoxin level was associated with respiratory symptoms or IgE sensitisation but the association of lung function with endotoxin levels may be modified by CD14-genotype.
  •  
5.
  •  
6.
  •  
7.
  • Chen, C-M, et al. (författare)
  • Geographical variation and the determinants of domestic endotoxin levels in mattress dust in Europe
  • 2012
  • Ingår i: Indoor Air. - : Hindawi Limited. - 0905-6947 .- 1600-0668. ; 22:1, s. 24-32
  • Tidskriftsartikel (refereegranskat)abstract
    • Endotoxin exposures have manifold effects on human health. The geographical variation and determinants of domestic endotoxin levels in Europe have not yet been extensively described. To investigate the geographical variation and determinants of domestic endotoxin concentrations in mattress dust in Europe using data collected in the European Community Respiratory Health Survey follow-up (ECRHS II). Endotoxin levels were measured in mattress dust from 974 ECRHS II participants from 22 study centers using an immunoassay. Information on demographic, lifestyle, and housing characteristics of the participants was obtained in face-to-face interviews. The median endotoxin concentration in mattress dust ranged from 772 endotoxin units per gram (EU/g) dust in Reykjavik, Iceland, to 4806 EU/g in Turin, Italy. High average outdoor summer temperature of study center, cat or dog keeping, a high household crowding index, and visible damp patches in the bedroom were significantly associated with a higher endotoxin concentrations in mattress dust. There is a large variability in domestic endotoxin levels across Europe. Average outdoor summer temperature of study center, which explains only 10% of the variation in domestic endotoxin level by center, is the strongest meteorological determinant. The observed variation needs to be taken into account when evaluating the health effects of endotoxin exposures in international contexts. PRACTICAL IMPLICATIONS: The incoherent observations of the health effects of endotoxin may be partly owing to the geographical heterogeneity of endotoxin exposure. Therefore, the observed variation should be considered in further studies. Measurements of indoor endotoxin are recommended as an indicator for the level of exposures of individual domestic environments.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 24

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy