SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Dressel Holger) "

Sökning: WFRF:(Dressel Holger)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Byber, Katarzyna, et al. (författare)
  • Humidification of indoor air for preventing or reducing dryness symptoms or upper respiratory infections in educational settings and at the workplace
  • 2021
  • Ingår i: Cochrane Database of Systematic Reviews. - : John Wiley & Sons. - 1469-493X. ; :12
  • Forskningsöversikt (refereegranskat)abstract
    • Background: Indoor exposure to dry air during heating periods has been associated with dryness and irritation symptoms of the upper respiratory airways and the skin. The irritated or damaged mucous membrane poses an important entry port for pathogens causing respiratory infections.Objectives: To determine the effectiveness of interventions that increase indoor air humidity in order to reduce or prevent dryness symptoms of the eyes, the skin and the upper respiratory tract (URT) or URT infections, at work and in educational settings.Search methods: The last search for all databases was done in December 2020. We searched Ovid MEDLINE, Embase, CENTRAL (Cochrane Library), PsycINFO, Web of Science, Scopus and in the field of occupational safety and health: NIOSHTIC-2, HSELINE, CISDOC and the In-house database of the Division of Occupational and Environmental Medicine, University of Zurich. We also contacted experts, screened reference lists of included trials, relevant reviews and consulted the WHO International Clinical Trials Registry Platform (ICTRP).Selection criteria: We included controlled studies with a parallel group or cross-over design, quasi-randomised studies, controlled before-and-after and interrupted time-series studies on the effects of indoor air humidification in reducing or preventing dryness symptoms and upper respiratory tract infections as primary outcomes at workplace and in the educational setting. As secondary outcomes we considered perceived air quality, other adverse events, sick leave, task performance, productivity and attendance and costs of the intervention.Data collection and analysis: Two review authors independently screened titles, abstracts and full texts for eligibility, extracted data and assessed the risks of bias of included studies. We synthesised the evidence for the primary outcomes 'dry eye', 'dry nose', 'dry skin', for the secondary outcome 'absenteeism', as well as for 'perception of stuffiness' as the harm-related measure. We assessed the certainty of evidence using the GRADE system.Main results: We included 13 studies with at least 4551 participants, and extracted the data of 12 studies with at least 4447 participants. Seven studies targeted the occupational setting, with three studies comprising office workers and four hospital staff. Three of them were clustered cross-over studies with 846 participants (one cRCT), one parallel-group controlled trial (2395 participants) and three controlled before-and-after studies with 181 participants. Five studies, all CTs, with at least 1025 participants, addressing the educational setting, were reported between 1963 and 1975, and in 2018. In total, at least 3933 (88%) participants were included in the data analyses. Due to the lack of information, the results of the risk of bias assessment remained mainly unclear and the assessable risks of bias of included studies were considered as predominantly high. Primary outcomes in occupational setting: We found that indoor air humidification at the workplace may have little to no effect on dryness symptoms of the eye and nose (URT). The only cRCT showed a significant decrease in dry eye symptoms among working adults (odds ratio (OR) 0.54, 95% confidence interval (CI) 0.37 to 0.79) with a low certainty of the evidence. The only cluster non-randomised cross-over study showed a non-significant positive effect of humidification on dryness nose symptoms (OR 0.87, 95% CI 0.53 to 1.42) with a low certainty of evidence. We found that indoor air humidification at the workplace may have little and non-significant effect on dryness skin symptoms. The pooled results of two cluster non-RCTs showed a non-significant alleviation of skin dryness following indoor air humidification (OR 0.66, 95% CI 0.33 to 1.32) with a low certainty of evidence. Similarly, the pooled results of two before-after studies yielded no statistically significant result (OR 0.69, 95% CI 0.33 to 1.47) with very low certainty of evidence No studies reported on the outcome of upper respiratory tract infections. No studies conducted in educational settings investigated our primary outcomes. Secondary outcomes in occupational setting: Perceived stuffiness of the air was increased during the humidification in the two cross-over studies (OR 2.18, 95% CI 1.47 to 3.23); (OR 1.70, 95% CI 1.10 to 2.61) with low certainty of evidence. Secondary outcomes in educational setting: Based on different measures and settings of absenteeism, four of the six controlled studies found a reduction in absenteeism following indoor air humidification (OR 0.54, 95% CI 0.45 to 0.65; OR 0.38, 95% CI 0.15 to 0.96; proportion 4.63% versus 5.08%).Authors' conclusions: Indoor air humidification at the workplace may have little to no effect on dryness symptoms of the eyes, the skin and the URT. Studies investigating illness-related absenteeism from work or school could only be summarised narratively, due to different outcome measures assessed. The evidence suggests that increasing humidification may reduce the absenteeism, but the evidence is very uncertain. Future RCTs involving larger sample sizes, assessing dryness symptoms more technically or rigorously defining absenteeism and controlling for potential confounders are therefore needed to determine whether increasing indoor air humidity can reduce or prevent dryness symptoms of the eyes, the skin, the URT or URT infections at work and in educational settings over time.
  •  
2.
  • Högman, Marieann, et al. (författare)
  • ERS technical standard : Global Lung Function Initiative reference values for exhaled nitric oxide (FENO)
  • 2024
  • Ingår i: European Respiratory Journal. - : European Respiratory Society. - 0903-1936 .- 1399-3003. ; 63:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Elevated levels of exhaled nitric oxide at a flow of 50 mL·s-1 (FENO50) are an important indicator of Th2 airway inflammation and may aid clinicians in the diagnosis and monitoring of asthma. This study aimed to derive Global Lung Function Initiative reference equations and the upper limit of normal for FENO50Available individual FENO50 data were collated and harmonised using consensus-derived variables and definitions. Data collected from individuals who met the harmonised definition of "healthy" were analysed using generalised additive models of location shape and scale (GAMLSS) technique.Data were retrospectively collated from 34 782 individuals from 34 sites in 15 countries, of whom 8022 met the definition of healthy (19 sites, 11 countries). Overall, height, age and sex only explained 12% of the between-subject variability of FENO50 (R2=0.12). The addition of NO device was a predictor of FENO50 and between-subject variability, such that the healthy range of values and the upper limit of normal varied depending on which device was used. The range of FENO50 values observed in healthy individuals was also very wide, and the heterogeneity was partially explained by the device used. The heterogeneity between sites remained within a sub-set of data where FENO50 was measured using the same device and a stricter definition of health (n=1027).Available FENO50 data collected from different sites using different protocols and devices was too variable to develop a single all-age reference equation. Further standardisation of NO devices and measurement is required before population reference values might be derived.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy