SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ekroth Rolf 1944) "

Sökning: WFRF:(Ekroth Rolf 1944)

  • Resultat 1-10 av 17
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Åmark, Kerstin, 1967, et al. (författare)
  • Blood cardioplegia provides superior protection in infant cardiac surgery.
  • 2005
  • Ingår i: The Annals of thoracic surgery. - : Elsevier BV. - 1552-6259 .- 0003-4975. ; 80:3, s. 989-94
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: We hypothesized that blood cardioplegia preserves myocardial metabolism and function more effectively than St Thomas' crystalloid cardioplegia in infant cardiac surgery. METHODS: Thirty infants with atrioventricular septal defects were randomly allocated to either blood or crystalloid intermittent cold (4 degrees C) cardioplegia. Arterial and coronary sinus blood was analyzed for lactate and oxygen. Cardiac output (thermodilution) and left ventricular function (echocardiography) were evaluated. RESULTS: The lactate concentration in coronary sinus blood early after bypass was significantly higher after crystalloid cardioplegia than after blood cardioplegia (2.1 +/- 0.3 vs 1.3 +/- 0.1 mmol/L, p = 0.006), with a significant myocardial release of lactate after crystalloid but not after blood cardioplegia. Oxygen extraction (arterial-coronary sinus O2 content) was higher early after crystalloid cardioplegia (3.02 +/- 0.13 vs 2.35 +/- 0.22 mmol/L, p = 0.01), possibly reflecting a difference in oxygen debt. The cardiac index was higher after blood cardioplegia (4.9 +/- 0.3 vs 4.0 +/- 0.3 L/min(-1)/m(-2), p = 0.04) and echocardiographic grading of left ventricular function was better (4.1 +/- 0.17 vs 3.5 +/- 0.22 arbitrary units, p = 0.046). CONCLUSIONS: This study indicates that blood cardioplegia preserves myocardial metabolism and function more effectively than crystalloid cardioplegia in infant cardiac surgery. The clinical significance of this finding is uncertain, but the more than 20% increase in cardiac index in the critical phase during weaning from bypass may be advantageous.
  •  
3.
  • Åmark, Kerstin, 1967, et al. (författare)
  • Myocardial metabolism is better preserved after blood cardioplegia in infants.
  • 2006
  • Ingår i: The Annals of thoracic surgery. - : Elsevier BV. - 1552-6259 .- 0003-4975. ; 82:1, s. 172-8
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: We have previously reported improved hemodynamic function after blood cardioplegia in comparison with crystalloid cardioplegia. Furthermore, lactate was released from the heart after crystalloid cardioplegia but not after blood cardioplegia. The purpose of this study was to determine whether the difference in substrate metabolism between the two cardioplegia methods was restricted to lactate, or whether the difference in metabolic derangement was more extensive. METHODS: Thirty consecutive infants with complete atrioventricular septal defects were included in this prospective, randomized, controlled study. Arterial and coronary sinus blood concentrations of substrates and amino acids were measured after weaning from bypass. RESULTS: After crystalloid cardioplegia, there was a myocardial uptake of glutamate (p = 0.003), leucine (p = 0.03), lysine (p = 0.003), and beta-hydroxybutyrate (p = 0.004), whereas lactate was released (p = 0.03). After blood cardioplegia, there was a myocardial uptake of free fatty acids (p = 0.01) but no uptake of amino acids and no release of lactate. CONCLUSIONS: There are differences in myocardial substrate metabolism between blood cardioplegia and crystalloid cardioplegia, which involve carbohydrates and amino acids. The differences may include lipids but our data in this respect are not conclusive.
  •  
4.
  •  
5.
  •  
6.
  • Ekroth, Rolf, 1944, et al. (författare)
  • Does off-pump coronary surgery endanger long term survival?
  • 2008
  • Ingår i: Scandinavian cardiovascular journal : SCJ. - : Informa UK Limited. - 1401-7431 .- 1651-2006. ; 42:2, s. 99-101
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • In this issue Ibrahim and co-authors report on technical hazards of off-pump (without heart lung machine) coronary surgery 1. Their findings are in line with meta-analyses of randomized trials which indicate that under-grafting and graft-failures are more common after off-pump than after standard operations. The risk that the objectives of coronary bypass surgery are endangered is discussed in relation to evidence based medicine. A moratorium is suggested until conclusive data are available.
  •  
7.
  • Ekroth, Rolf, 1944, et al. (författare)
  • High or low risk coronary patients - who gets the highest priority?
  • 2010
  • Ingår i: Scandinavian cardiovascular journal : SCJ. - : Informa UK Limited. - 1651-2006 .- 1401-7431. ; 44:4, s. 195-6
  • Tidskriftsartikel (refereegranskat)abstract
    • Coronary revascularisation is more often used in patients at small risk and with little to gain than in patients at high risk and much to gain. This is against current guide-lines and is wasteful. The problem if aggravated by socioeconomic bias. A redesigned reimbursement system, based on measured improved quality of life and survival, would encourage a more efficient use of resources.
  •  
8.
  •  
9.
  • Jensen, Eva, et al. (författare)
  • Changes in hemostasis during pediatric heart surgery: impact of a biocompatible heparin-coated perfusion system.
  • 2004
  • Ingår i: The Annals of thoracic surgery. - : Elsevier BV. - 0003-4975. ; 77:3, s. 962-7
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: This study describes the response in hemostasis during open-heart surgery with cardiopulmonary bypass (CPB) in children (<== 10 kg) and tests the hypothesis that the use of a biocompatible perfusion system, in comparison with a conventional system, causes less hemostatic activation. METHODS: Prospective, randomized, controlled clinical study. Forty consecutive children <== 10 kg were included and divided into two groups: group bioc. (n = 19) treated with a fully heparin-coated system, centrifugal pump, and a closed circuit, and group conv. (n = 21) treated with an uncoated system, roller pump, and a hard shell venous reservoir. Concentrations of plasma thrombin-antithrombin (TAT), D-dimer, tissue plasminogen activator antigen (t-PA ag), and the complex consisting of tissue plasminogen activator and its inhibitor plasminogen activator inhibitor-1 (t-PA-PAI-1) were measured. RESULTS: The biochemical variables measured increased significantly in both groups during the study period. There was less activation of fibrinolysis during cardiopulmonary bypass (t-PA ag: p = 0.009) in patients treated with the biocompatible perfusion system than in patients treated with the conventional system. A trend in favor of the biocompatible system based on the D-dimer and TAT data (p = 0.07 for both measurements) was observed but no significant intergroup differences regarding these variables or t-PA-PAI-1 were found. CONCLUSIONS: Open-heart surgery with cardiopulmonary bypass in children (<== 10 kg) causes transient activation of the coagulation and fibrinolytic systems. This study demonstrates that the use of a biocompatible perfusion system results in a lower extent of activation of fibrinolysis during CPB than the use of a conventional system.
  •  
10.
  • Jensen, Eva, et al. (författare)
  • Influence of two different perfusion systems on inflammatory response in pediatric heart surgery.
  • 2003
  • Ingår i: The Annals of thoracic surgery. - 0003-4975. ; 75:3, s. 919-25
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: This study tests the hypothesis that a cardiopulmonary bypass system that combines complete heparin-coating, a centrifugal pump, and a closed circuit in comparison with a conventional system (uncoated system, roller pump, and hard shell venous reservoir) attenuates the inflammatory response in pediatric heart surgery. METHODS: In a prospective randomized controlled clinical study 40 consecutive children weighing 10 kg or less were included and divided into two groups. Concentrations of complement proteins (C3a, sC5b-9, C4d, and Bb), granulocyte degranulation products (polymorphonuclear [PMN] elastase), and proinflammatory cytokines (tumor necrosis factor [TNF]-alpha, interleukin [IL]-6, and IL-8) were measured. RESULTS: C3a and sC5b-9 concentrations were lower (C3a, p < 0.001; sC5b-9, p = 0.01) in the combined (heparin-coated/centrifugal pump/closed reservoir) group, the peak values being 58% and 37% of conventional group values. The Bb- and C4d-fragment values indicated activation of the complement system through the alternative pathway in both groups. PMN elastase concentrations were lower (p = 0.02) in the combined group, the peak values being 43% of conventional group values. There were no significant intergroup differences regarding TNF-alpha, IL-6, or IL-8 concentrations. CONCLUSIONS: The use of a fully heparin-coated system, a centrifugal pump, and a closed circuit during CPB in children (10 kg or less) leads to a lower degree of complement activation and PMN elastase release compared with a conventional system.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 17

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy